Voltage Distribution Analysis of High Coupled Split Reactor in 500 kV AC Fault Current Limiter

被引:5
|
作者
Wu, Kaijian [1 ,2 ]
Yuan, Zhao [1 ,2 ]
Ye, Jingjing [1 ,2 ]
Liu, Junxiang [3 ]
Mo, Wenxiong [3 ]
Wang, Yong [3 ]
Chen, Lixue [1 ,2 ]
He, Junlei [1 ,2 ]
Pan, Yuan [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Key Lab Pulsed Power Technol, Minist Educ, Wuhan 430074, Peoples R China
[3] Guangzhou Power Supply Bur Co Ltd, Test & Res Inst, Guangzhou 514010, Peoples R China
关键词
Encapsulation; Integrated circuit modeling; Insulation; Couplings; Inductance; Power grids; Inductors; Fault current limiter; high coupled split reactor; insulation; lightning impulse; switching impulse; FAST TRANSIENT OVERVOLTAGE; TRANSFORMER; FREQUENCY; CIRCUIT;
D O I
10.1109/ACCESS.2020.3029796
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the increase of short circuit current, measures should be taken to reduce the impact. Among various measures, a new technique to interrupt or limit current is proposed and applied to power grid based on high coupled split reactor (HCSR). As the key equipment in new technique, the insulation design of HCSR is a priority. Previous works mainly involve voltage across HCSR in different working states, and take the whole voltages as design requirements. It is rough and takes no account of voltage distribution inside HCSR, thus not suitable for insulation design of HCSR. In order to analyze the overvoltage problems and determine insulation demands for HCSR, this article establishes the equivalent circuit model in turn unit to calculate the voltage distribution inside HCSR, which is simplified and accurate enough for HCSR. A 500 kV AC fault current limiter is briefly introduced, and voltages between turns or arms in HCSR are obtained. The voltage between turns are evenly distributed and voltage between arms are very low under switching impulse. As for lightning impulse, maximum turn-to-turn voltages mainly appear in the end of encapsulations, and the voltage between arms in current sharing state is considerable. This article gives the calculation method and general rules of voltage distribution inside HCSR, and it has great significance for the insulation design of HCSR.
引用
收藏
页码:185804 / 185815
页数:12
相关论文
共 50 条
  • [1] Fault Detection System for 500 kV AC Fault Current Limiter Based on High-Coupled Split Reactor
    Liu, Zhixiong
    Chen, Hongkun
    Hu, Zhuoran
    Li, Yizhang
    Wu, Xinjian
    Peng, Heping
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (08)
  • [2] A Topology of 500 kV Fault Current Limiter Based on a High Coupling Split Reactor
    Liu J.
    Ye J.
    Yuan Z.
    Wu K.
    Mo W.
    Wang Y.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (08): : 2828 - 2837
  • [3] Interruption Characteristics of High-speed Switches in 500 kV Fault Current Limiter with High Coupled Split Reactance
    Zhang, Yanzhe
    Xiu, Shixin
    Tang, Qiang
    Jia, Shenli
    Chu, Bo
    Mo, Wenxiong
    Wang, Yong
    Su, Haibo
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2023, 9 (04): : 1577 - 1584
  • [4] Research on a New Type of Fault Current Limiter Based on High Coupled Split Reactor
    Mo, Wenxiong
    Liu, Junxiang
    Wang, Yong
    Gan, Lin
    Su, Haibo
    Zhu, Lu
    Qiao, Shengya
    Wu, Kaijian
    Yuan, Zhao
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 1513 - 1522
  • [5] Calculation and Analysis of Internal Overvoltage of 500 kV High Coupled Split Reactor
    Mo, Wenxiong
    Wu, Kaijian
    Yuan, Zhao
    Chen, Lixue
    Liu, Junxiang
    Zhu, Lu
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (02): : 495 - 503
  • [6] Design Improvement of Fault Current Limiter Based on High Coupled Split Reactor Considering the Impact of Internal Ground Fault
    Chen, Jingyao
    Chen, Hongkun
    Chen, Lei
    Wu, Xingjian
    Zhu, Lu
    Peng, Heping
    Mo, Wenxiong
    Wang, Yong
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (08)
  • [7] Research on EMC Tests for Economical High-voltage AC Current Limiter of 500kV and Above
    Shen, Yue
    Jiang, Nan
    Han, Shanglin
    Liu, Chuang
    2020 INTERNATIONAL CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING, DIAGNOSTIKA, 2020, : 142 - 145
  • [8] High Voltage Calculations for a 380 kV Superconducting Fault Current Limiter
    Fink, S.
    Noe, M.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (03) : 1 - 5
  • [9] Experiments with a high voltage (40 kV) superconducting fault current limiter
    Verhaege, T
    Cottevielle, C
    Estop, P
    Quemener, M
    Tavergnier, JP
    Bekhaled, M
    Bencharab, C
    Bonnet, P
    Laumond, Y
    Pham, VD
    Poumarede, C
    Therond, PG
    CRYOGENICS, 1996, 36 (07) : 521 - 526
  • [10] Research on the Lightning Intruding Overvoltage and Protection Measures of 500 kV AC Fault Current Limiter
    Chen, Changfu
    Han, Yongxia
    Liu, Junxiang
    Mo, Wenxiong
    Yuan, Zhao
    Huang, Jianning
    Su, Haibo
    Zhang, Xiancong
    Wu, Kaijian
    ENERGIES, 2019, 12 (20)