Choroidal Thickness in Open- angle Glaucoma

被引:17
|
作者
Jonas, Jost B. [1 ]
Steinmetz, Philippe [1 ]
Forster, Tessa M. [1 ]
Schlichtenbrede, Frank C. [1 ]
Harder, Bjoern C. [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, Med Fac Mannheim, Heidelberg, Germany
关键词
choroidal thickness; open-angle glaucoma; enhanced depth imaging; optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; RETINAL CHANGES; CLOSURE; EYES;
D O I
10.1097/IJG.0000000000000063
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To examine choroidal thickness in open-angle glaucoma.Methods:The hospital-based case series study included a study group with patients with open-angle glaucoma and a control group. Choroidal thickness was measured by enhanced depth imaging by spectral domain optical coherence tomography.Results:The study group included 39 patients (71 eyes) and the control group consisted of 189 patients (228 eyes) with no significant difference between both groups in age (P=0.16) and refractive error (P=0.07). Choroidal thickness in the foveal region (P=0.18), at a distance of 1000 m from the fovea (P=0.39), 2000 m from the fovea (P=0.46), and 2500 m from the fovea (P=0.53) did not vary significantly between both groups. In multivariable analysis with adjustment for age and refractive error, choroidal thickness at the fovea [P=0.12; regression coefficient B: minus-8.60; 95% confidence interval (CI): -19.3, 2.1], at a horizontal distance of 1000 m from the fovea (P=0.30; regression coefficient B: -4.98; 95% CI: -14.3, 4.4), 2000 m from the fovea (P=0.20; regression coefficient B: -20.9; 95% CI: -53.2, 11.3), and 2500 m from the fovea (P=0.45; regression coefficient B: -2.70; 95% CI: -9.67, 4.27) was not significantly associated with the diagnosis of glaucoma. In binary regression analysis with adjustment for age and refractive error, presence of glaucoma was significantly associated neither with subfoveal choroidal thickness [P=0.12; odds ratio (OR): 0.997; 95% CI: 0.993, 1.001] nor with choroidal thickness at a horizontal distance of 1000 m from the fovea (P=0.47; OR: 0.998; 95% CI: 0.993, 1.002), 2000 m from the fovea (P=0.23; OR: 0.997; 95% CI: 0.993, 1.002), or 2500 m from the fovea (P=0.46; OR: 0.998; 95% CI: 0.992, 1.004).Conclusions:After adjusting for age and refractive error, open-angle glaucoma was not significantly associated with a marked thinning or a thickening of the choroid in the foveal and parafoveal region.
引用
收藏
页码:619 / 623
页数:5
相关论文
共 50 条
  • [41] Choroidal Thickness in Idiopathic Subfoveal Choroidal Neovacularization
    Cao, Xu-Sheng
    Peng, Xiao-Yan
    You, Qi-Sheng
    Zhang, Yong-Peng
    Jonas, Jost B.
    OPHTHALMOLOGICA, 2014, 231 (04) : 221 - 225
  • [42] Association between choroidal thickness and anterior chamber segment in eyes with narrow or open-angle
    Li, Song-Feng
    Wu, Ge-Wei
    Chen, Chang-Xi
    Shen, Ling
    Zhang, Zhi-Bao
    Gao, Fei
    Wang, Ning-Li
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (08) : 1143 - 1147
  • [43] Association between choroidal thickness and anterior chamber segment in eyes with narrow or open-angle
    Song-Feng Li
    Ge-Wei Wu
    Chang-Xi Chen
    Ling Shen
    Zhi-Bao Zhang
    Fei Gao
    Ning-Li Wang
    International Journal of Ophthalmology, 2016, (08) : 1143 - 1147
  • [44] Efficiency of Choroidal Thickness Monitoring to Prevent Topiramate Induced Acute Angle Closure Glaucoma
    Kara, Selcuk
    Ozcimen, Muammer
    Aydin, Hacer Doganay
    Sakarya, Yasar
    Gencer, Baran
    Tufan, H. Ali
    Arikan, Sedat
    EUROPEAN JOURNAL OF GENERAL MEDICINE, 2015, 12 (01): : 7 - 12
  • [45] Central Visual Field Damage and Parapapillary Choroidal Microvasculature Dropout in Primary Open-Angle Glaucoma
    Lee, Eun Ji
    Kim, Tae-Woo
    Kim, Ji-Ah
    Kim, Jeong-Ah
    OPHTHALMOLOGY, 2018, 125 (04) : 588 - 596
  • [46] Comparison of ganglion cell-inner plexiform layer thickness in exfoliative glaucoma and primary open-angle glaucoma
    Demirtas, Atilim Armagan
    Cicek, Ayse Ozkose
    Duru, Zeynep
    Ulusoy, Dondu Melek
    Ozsaygili, Cemal
    Duru, Necati
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2021, 34
  • [47] Decreased iris thickness on swept-source optical coherence tomography in patients with primary open-angle glaucoma
    Chen, Zhiqi
    Liang, Xin
    Chen, Wei
    Wang, Ping
    Wang, Junming
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (07) : 696 - 703
  • [48] Choroidal Thickness in the Subtypes of Angle Closure: An EDI-OCT Study
    Huang, Wenbin
    Wang, Wei
    Gao, Xinbo
    Li, Xingyi
    Li, Zheng
    Zhou, Minwen
    Chen, Shida
    Zhang, Xiulan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (13) : 7849 - 7853
  • [49] CHOROIDAL THICKNESS IN HEALTHY CHILDREN
    Park, Kyung-Ah
    Oh, Sei Yeul
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (09): : 1971 - 1976
  • [50] Diurnal macular choroidal area fluctuation in normal and primary open angle glaucoma groups
    Mu Li
    Jin-Min Guo
    Xiao-Lan Xu
    Jun-Ming Wang
    International Journal of Ophthalmology, 2017, (08) : 1233 - 1238