Multilayer X-ray sensitive CCDs

被引:1
|
作者
Skrylev, AS [1 ]
Skrylev, PA [1 ]
Shilin, VA [1 ]
机构
[1] Sci Soc TOPEK, Moscow 103897, Russia
来源
SECOND CONFERENCE ON PHOTONICS FOR TRANSPORTATION | 2002年 / 4761卷
关键词
CCD; CMOS photodiode; X-ray detector; quantum efficiency (QE); quantum output (QO); coefficient of absorption (CA); mass coefficient of absorption (MCA); spectral transmission (ST);
D O I
10.1117/12.463478
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The hybrid multilayer X-ray sensitive structure with direct enlightening has been developed. The direct enlightening provides high quantum output of absorbed light. It is necessary to combine an output signals from different layers. An electronic calibration allows partially combining that output signals. The simulation of multilayer X-ray CCD and CMOS detectors for energy range from 1 to 100 keV has been carried out. In comparison to previous detectors, its sensitivity is increased in 80-120 times. This advantage has significant meaning for medicine and other fields.
引用
收藏
页码:215 / 225
页数:11
相关论文
共 50 条
  • [1] Medical X-ray sensitive apparatus based on CCDs
    Gnedenko, V
    Phajnberg, E
    Krasnjuk, A
    Stenin, V
    Larionov, S
    Salnikova, O
    Shilin, V
    Screalev, A
    THIRD CONFERENCE ON PHOTONIC SYSTEMS FOR ECOLOGICAL MONITORING, 1997, 3200 : 84 - 87
  • [2] EVENT RECOGNITION IN X-RAY CCDS
    OWENS, A
    MINEO, T
    MCCARTHY, KJ
    WELLS, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2): : 353 - 365
  • [3] Quantum efficiency of X-ray CCDs
    Prigozhin, G
    Woo, J
    Gregory, JA
    Loomis, AH
    Bautz, MW
    Ricker, GR
    Kraft, S
    SOLID STATE SENSOR ARRAYS: DEVELOPMENT AND APPLICATIONS II, 1998, 3301 : 108 - 115
  • [4] CCDS MAP THE X-RAY SKY
    WELLS, A
    POUNDS, K
    PHYSICS WORLD, 1993, 6 (05) : 32 - 36
  • [5] X-ray CCDs developed for the joint European X-ray telescope
    Owens, Alan
    Abbey, A.F.
    Brauninger, H.
    Burkert, W.
    Castelli, C.
    Chapman, H.
    Dowson, J.
    Li, Y.
    McCarthy, Kieran J.
    Pool, P.
    Sims, M.R.
    Spragg, J.
    Watson, D.J.
    Wells, A.
    Willingale, R.
    Journal of X-Ray Science and Technology, 1996, 6 (03)
  • [6] CCDs for X-ray topography at synchrotrons
    Castelli, CM
    Allinson, NM
    Barnett, SJ
    Clark, GF
    Moon, K
    Whitehouse, CR
    Wells, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 391 (03): : 481 - 484
  • [7] CCDs for future X-ray astronomy missions
    Holland, AD
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 586 - 597
  • [8] X-ray polarimetry - A novel application of CCDs
    Bogner, M
    Buschhorn, G
    Kotthaus, R
    Oberhuber, R
    Rzepka, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 529 - 531
  • [9] X-RAY SENSITIVE CCDS FROM 0KEV TO 1MEV
    FLINT, IT
    FRANCIS, HJ
    HOLLAND, AD
    WELLS, A
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (121): : 281 - 288
  • [10] Developments in MOS CCDs for X-ray astronomy
    Pool, PJ
    Holtom, R
    Burt, DJ
    Holland, AD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 9 - 15