A review on windcatcher for passive cooling and natural ventilation in buildings, Part 1: Indoor air quality and thermal comfort assessment

被引:169
作者
Jomehzadeh, Fatemeh [1 ,2 ]
Nejat, Payam [1 ]
Calautit, John Kaiser [3 ]
Yusof, Mohd Badruddin Mohd [1 ]
Zaki, Sheikh Ahmad [4 ]
Hughes, Ben Richard [3 ]
Yazid, Muhammad Noor Afiq Witri Muhammad [5 ]
机构
[1] Univ Teknol Malaysia, Fac Civil Engn, Skudai 81310, Johor, Malaysia
[2] Adv Bldg & Environm Res ABER Ctr, Tehran, Iran
[3] Univ Sheffield, Dept Mech Engn, Sheffield S10 2TN, S Yorkshire, England
[4] Univ Teknol Malaysia, Malaysia Japan Int Inst Technol, Kuala Lumpur, Malaysia
[5] Univ Teknol Malaysia, Fac Mech Engn, Skudai 81310, Johor, Malaysia
关键词
Windcatcher; Natural ventilation; Passive cooling; Wind tower; Thermal comfort; Indoor air quality (IAQ); Badgir; COMMERCIAL WIND TOWERS; ENERGY-EFFICIENT; COMPUTATIONAL ANALYSIS; PERFORMANCE ANALYSIS; HEAT-TRANSFER; CATCHER; HOT; SYSTEM; FLOW; CFD;
D O I
10.1016/j.rser.2016.11.254
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The most prominent challenge in 21th century is global warming which seriously threats the mankind. Building sector with 40% of global energy consumption and GHG emission play a key role in this threat. In this regard, the impact of cooling systems cannot be ignored where along with ventilation and heating systems totally account for 60% of energy consumed in buildings. Passive cooling systems can be a promising alternative to reduce energy consumption. One of the oldest passive cooling system that is still being used today is windcatcher. By manipulating pressure differences and the buoyancy effect, an adequate level of ventilation in buildings can be provided by windcatchers. Since most of the previous windcatcher studies assessed the design characteristics, the current investigation focused on the indoor air quality (IAQ) and thermal comfort aspects. The review details and compares the different theoretical and experimental methods employed by researchers in different case studies to assess the IAQ and thermal comfort. It was found that most IAQ studies were conducted in the UK using CFD and experimental techniques. Previous studies assessed IAQ based on several parameters such as air flow rate, air change rate, CO2 concentration, air change effectiveness and mean age of air. The findings of the studies revealed that satisfactory IAQ were generally achieved using the windcatcher. On the other hand, thermal comfort studies of windcatchers were mainly conducted in hot climates such as in the Middle East. In addition to night ventilation, the review also looked into the different types of cooling methods incorporated with windcatchers such as evaporative cooling, earth to air heat exchangers (EAHE) and heat transfer devices (HTD). Night ventilation was found to be effective in temperate and cold conditions while additional cooling using evaporative cooling, EAHE and HTD were found to be necessary in hot climates.
引用
收藏
页码:736 / 756
页数:21
相关论文
共 134 条
[1]   A review on natural ventilation applications through building facade components and ventilation openings in tropical climates [J].
Aflaki, Ardalan ;
Mahyuddin, Norhayati ;
Mahmoud, Zakaria Al-Cheikh ;
Baharum, Mohamad Rizal .
ENERGY AND BUILDINGS, 2015, 101 :153-162
[2]   An experimental study on the evaluation of natural ventilation performance of a two-sided wind-catcher for various wind angles [J].
Afshin, M. ;
Sohankar, A. ;
Manshadi, M. Dehghan ;
Esfeh, M. Kazemi .
RENEWABLE ENERGY, 2016, 85 :1068-1078
[3]   PERFORMANCE ANALYSIS OF A WIND-CATCHER WITH WATER SPRAY [J].
Ahmadikia, H. ;
Moradi, A. ;
Hojjati, M. .
INTERNATIONAL JOURNAL OF GREEN ENERGY, 2012, 9 (02) :160-173
[4]   The effect of a ventilated interior courtyard on the thermal performance of a house in a hot-arid region [J].
Al-Hemiddi, NA ;
Al-Saud, KAM .
RENEWABLE ENERGY, 2001, 24 (3-4) :581-595
[5]   Outdoor airflow analysis and potential for passive cooling in the modern urban context of Dubai [J].
Al-Sallal, Khaled A. ;
Al-Rais, Laila .
RENEWABLE ENERGY, 2012, 38 (01) :40-49
[6]  
[Anonymous], PROCEEDING 2 ANN S A
[7]  
[Anonymous], P 22 C PASS LOW EN A
[8]  
[Anonymous], 2010, WORLD ACAD SCI ENG T
[9]  
[Anonymous], NUMER HEAT TRANSF A
[10]  
[Anonymous], 2014, INT J CIV ARCH STRUC