Scanning transmission microscopy using a position-sensitive detector

被引:8
|
作者
Ayres, Mark R.
McLeod, Robert R.
机构
[1] InPhase Technol Inc, Longmont, CO 80501 USA
[2] Univ Colorado, Dept Elect Engn, Boulder, CO 80309 USA
关键词
D O I
10.1364/AO.45.008410
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical data manipulation technologies increasingly employ densely aperiodic optical 3D phase elements. Refinement of such technologies will require the capability to quantitatively characterize the volumetric dielectric modulation of an optical sample to a high level of precision and spatial resolution. We present a scanning transmission microscopy system that uses a position-sensitive detector to impart sensitivity to both the phase and absorption components. We describe the layout of the instrument and then derive its phase and absorption transfer functions. Simulations and experiments are presented to validate the analysis. For phase detection, the instrument possesses depth-sectioning properties similar to those of a confocal microscope without the use of a pinhole, enabling full 3D object reconstruction. (c) 2006 Optical Society of America.
引用
收藏
页码:8410 / 8418
页数:9
相关论文
共 50 条
  • [1] SCANNING POSITION-SENSITIVE DETECTOR
    PODURETS, KM
    MITROFANOV, NL
    SOMENKOV, VA
    TYUGIN, AB
    SHILSHTEIN, SS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (03) : 520 - 522
  • [2] A POSITION-SENSITIVE TRANSMISSION TIME DETECTOR
    BUSCH, F
    PFEFFER, W
    KOHLMEYER, B
    SCHULL, D
    PUHLHOFFER, F
    NUCLEAR INSTRUMENTS & METHODS, 1980, 171 (01): : 71 - 74
  • [3] A GUINIER DIFFRACTOMETER WITH A SCANNING POSITION-SENSITIVE DETECTOR
    GOBEL, HE
    ADVANCES IN X-RAY ANALYSIS, 1982, 25 : 315 - 324
  • [4] Accuracy of position detection using a position-sensitive detector
    Schaefer, P
    Williams, RD
    Davis, GK
    Ross, RA
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (04) : 914 - 919
  • [5] A new position-sensitive transmission detector for epithermal neutron imaging
    Schooneveld, E. M.
    Tardocchi, M.
    Gorini, G.
    Kockelmann, W.
    Nakamura, T.
    Cippo, E. Perelli
    Postma, H.
    Rhodes, N.
    Schillebeeckx, P.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2009, 42 (15)
  • [6] FLEXIBLE POSITION-SENSITIVE DETECTOR
    ROGERS, RC
    ADLER, L
    CASKEY, M
    HERNANDEZ, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (04): : 557 - 557
  • [7] A POSITION-SENSITIVE PARTICLE DETECTOR
    ABBAS, I
    CAMPBELL, EEB
    FLUENDY, MAD
    KING, A
    MCGILL, CG
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (11): : 1044 - 1050
  • [8] POSITION-SENSITIVE DETECTOR FOR ELECTRONS
    MOAK, CD
    DATZ, S
    GARCIASANTIBANEZ, F
    CARLSON, TA
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1975, 6 (02) : 151 - 156
  • [9] Position-sensitive neutron detector
    Kuznetsov, AV
    Vakhtin, DN
    Radivojevich, Z
    Alkhazov, ID
    Lyapin, VG
    Trzaska, WH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 372 - 377
  • [10] SUBMICRON POSITION-SENSITIVE DETECTOR
    PUGATCH, VM
    ROSENFELD, AB
    LITOVCHENKO, PG
    BARABASH, LI
    NEMETS, OF
    PAVLENKO, YN
    VASILIEV, YO
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 70 (1-4): : 574 - 578