Anomaly detection and condition monitoring of wind turbine gearbox based on LSTM-FS and transfer learning

被引:46
作者
Zhu, Yongchao [1 ]
Zhu, Caichao [1 ]
Tan, Jianjun [1 ]
Tan, Yong [1 ]
Rao, Lei [2 ]
机构
[1] Chongqing Univ, State Key Lab Mech Transmiss, Chongqing 400044, Peoples R China
[2] CSSC Haizhuang Windpower Co Ltd, Chongqing 401122, Peoples R China
关键词
Wind turbine; Condition monitoring; Deep learning; Fuzzy synthesis; Transfer learning; LIFE-CYCLE ASSESSMENT; ACOUSTIC-EMISSION; FAULT-DIAGNOSIS; VIBRATION; RELIABILITY; TIME; IDENTIFICATION; RECOGNITION; GENERATION;
D O I
10.1016/j.renene.2022.02.061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To take full advantage of the limited monitoring data with fault information for operational state prediction in the case of the discrepancy in data distribution between the WTGs, a novel combined method is proposed based on the long short-term memory, fuzzy synthesis and feature-based transfer learning. After the statistical analysis and prediction of the monitoring indexes of two 2-MW WTGs with faulty information, an operational state calibration framework is proposed based on deep learning and fuzzy synthesis. Following this, three feature-based transfer learning methods are adopted to narrow the discrepancy among the data distribution of the WTGs. Correspondingly, feasibility verification of the proposed method is equally addressed. Case applications are performed using the actual monitoring data from No. 13 and 15 wind turbines of a wind farm in northern China. The results show that the operational state calibration framework can sensitively detect the potential fault information of the WTG in advance. Meanwhile, three transfer learning algorithms can effectively narrow the distance of the data distribution among the WTGs, and the classification accuracy can almost reach above 0.9. The proposed method can make full use of existing monitoring data with faulty information to predict the status of other WTGs.(c) 2022 Published by Elsevier Ltd.
引用
收藏
页码:90 / 103
页数:14
相关论文
共 49 条
  • [1] [Anonymous], 2010, P SCI TRACK EUROPEAN
  • [2] Anomaly detection and critical SCADA parameters identification for wind turbines based on LSTM-AE neural network
    Chen, Hansi
    Liu, Hang
    Chu, Xuening
    Liu, Qingxiu
    Xue, Deyi
    [J]. RENEWABLE ENERGY, 2021, 172 : 829 - 840
  • [3] Diagnosis of wind turbine faults with transfer learning algorithms
    Chen, Wanqiu
    Qiu, Yingning
    Feng, Yanhui
    Li, Ye
    Kusiak, Andrew
    [J]. RENEWABLE ENERGY, 2021, 163 : 2053 - 2067
  • [4] Ageing assessment of a wind turbine over time by interpreting wind farm SCADA data
    Dai, Juchuan
    Yang, Wenxian
    Cao, Junwei
    Liu, Deshun
    Long, Xing
    [J]. RENEWABLE ENERGY, 2018, 116 : 199 - 208
  • [5] Condition monitoring and fault detection in wind turbines based on cointegration analysis of SCADA data
    Dao, Phong B.
    Staszewski, Wieslaw J.
    Barszcz, Tomasz
    Uhl, Tadeusz
    [J]. RENEWABLE ENERGY, 2018, 116 : 107 - 122
  • [6] Sound and vibration-based pattern recognition for wind turbines driving mechanisms
    de la Hermosa Gonzalez-Carrato, Raul Ruiz
    [J]. RENEWABLE ENERGY, 2017, 109 : 262 - 274
  • [7] Critical Component Identification in Reliability Centered Asset Management of Power Distribution Systems Via Fuzzy AHP
    Dehghanian, Payman
    Fotuhi-Firuzabad, Mahmud
    Bagheri-Shouraki, Saeed
    Kazemi, Ali Asghar Razi
    [J]. IEEE SYSTEMS JOURNAL, 2012, 6 (04): : 593 - 602
  • [8] Predictive Modeling of a Two-Stage Gearbox towards Fault Detection
    Diehl, Edward J.
    Tang, J.
    [J]. SHOCK AND VIBRATION, 2016, 2016
  • [9] A comparative study of the effectiveness of vibration and acoustic emission in diagnosing a defective bearing in a planetry gearbox
    Elasha, Faris
    Greaves, Matthew
    Mba, David
    Fang, Duan
    [J]. APPLIED ACOUSTICS, 2017, 115 : 181 - 195
  • [10] Monitoring wind turbine gearboxes
    Feng, Yanhui
    Qiu, Yingning
    Crabtree, Christopher J.
    Long, Hui
    Tavner, Peter J.
    [J]. WIND ENERGY, 2013, 16 (05) : 728 - 740