Visual and optical quality of enhanced intermediate monofocal versus standard monofocal intraocular lens

被引:21
作者
Garzon, Nuria [1 ,2 ]
Poyales, Francisco [1 ]
Albarran-Diego, Cesar [3 ,4 ]
Rico-del-Viejo, Laura [1 ]
Perez-Sanz, Lidia [1 ]
Garcia-Montero, Maria [1 ,2 ]
机构
[1] Miranza Grp, C Galileo 104, Madrid 28003, Spain
[2] Univ Complutense Madrid, Fac Opt & Optometry, Optometry & Vis Dept, Madrid 28037, Spain
[3] Univ Valencia, Fac Phys, Opt Optometry & Vis Sci Dept, Dr Moliner 50, Burjassot 46100, Spain
[4] Clin Oftalmol Dr Gonzalo Munoz, C Marques de Sotelo 5, Valencia 46002, Spain
关键词
Cataract surgery; Monofocal intraocular lens; Monofocal with enhanced intermediate vision lens; Refraction; PERFORMANCE; VISION; DEPTH;
D O I
10.1007/s00417-022-05700-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Intraocular lens designs are constantly evolving, trying to obtain more spectacle independence after cataract surgery. This advantage can be linked to some disadvantages, such as optical quality decrease. For that reason, it is important to assess, not only the amount of vision provided but also the quality of vision once they are implanted. The purpose of the present work was to compare the visual performance between two monofocal intraocular models: a standard model and a monofocal with enhanced intermediate vision lens. Methods Prospective, randomized, comparative study. Sixty adult subjects scheduled to undergo bilateral cataract surgery and IOL implantation were randomized to receive one of the two IOLs in both eyes at Miranza IOA, Madrid, Spain (group A: monofocal with enhanced intermediate vision lens and group B: standard monofocal lens). Monocular outcomes (right eyes) determined 1 and 3 months postoperatively were photopic corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), perceived halo, corrected intermediate-distance contrast sensitivity, and higher-order aberrations. The impact of the new IOL in the postoperative management with autorefraction devices was also evaluated. Results No differences were found in CDVA between the two groups. Significant differences were detected between the two lenses evaluated in both total HOA (p = 0.028) and internal HOA (p = 0.037). Contrast sensitivity and halometry results obtained at 1 month were similar across the two IOL groups. Conclusion In patients undergoing cataract surgery, monofocal with enhanced intermediate vision IOL offered similar distance performance and contrast sensitivity along with perceived HOA and halos compared with the standard monofocal IOLs tested.
引用
收藏
页码:3617 / 3625
页数:9
相关论文
共 14 条
[1]   Enhancing the Intermediate Vision of Monofocal Intraocular Lenses Using a Higher Order Aspheric Optic [J].
Alarcon, Aixa ;
Canovas, Carmen ;
Koopman, Bram ;
Weeber, Henk ;
Auffarth, Gerd U. ;
Piers, Patricia A. .
JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (08) :520-+
[2]   Clinical evaluation of a new monofocal IOL with enhanced intermediate function in patients with cataract [J].
Auffarth, Gerd U. ;
Gerl, Matthias ;
Tsai, Linda ;
Janakiraman, D. Priya ;
Jackson, Beth ;
Alarcon, Aixa ;
Dick, H. Burkhard .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (02) :184-191
[3]   Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study [J].
Bellucci, R ;
Scialdone, A ;
Buratto, L ;
Morselli, S ;
Chierego, C ;
Criscuoli, A ;
Moretti, G ;
Piers, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) :712-717
[4]   A visual test based on a freeware software for quantifying and displaying night-vision disturbances: study in subjects after alcohol consumption [J].
Castro, Jose J. ;
Ortiz, Carolina ;
Pozo, Antonio M. ;
Anera, Rosario G. ;
Soler, Margarita .
THEORETICAL BIOLOGY AND MEDICAL MODELLING, 2014, 11
[5]   New testing software for quantifying discrimination capacity in subjects with ocular pathologies [J].
Castro, Jose J. ;
Jimenez, Jose R. ;
Ortiz, Carolina ;
Alarcon, Aixa ;
Anera, Rosario G. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)
[6]   Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction [J].
Garzon, Nuria ;
Garcia-Montero, Maria ;
Lopez-Artero, Esther ;
Poyales, Francisco ;
Albarran-Diego, Cesar .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09) :1265-1274
[7]  
Johnson&Johnson V, 2019, SUPPL OPHTH
[8]   Visual outcome, optical quality, and patient satisfaction with a new monofocal IOL, enhanced for intermediate vision: preliminary results [J].
Mencucci, Rita ;
Cennamo, Michela ;
Venturi, Daniel ;
Vignapiano, Roberto ;
Favuzza, Eleonora .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (03) :378-387
[9]  
Mico V., 2014, Astigmatism: Types, Diagnosis and Treatment Options, P27
[10]   People and eyes: statistical approaches in ophthalmology [J].
Murdoch, IE ;
Morris, SS ;
Cousens, SN .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (08) :971-973