Measuring the labeling efficiency of pseudocontinuous arterial spin labeling

被引:31
作者
Chen, Zhensen [1 ]
Zhang, Xingxing [2 ,3 ]
Yuan, Chun [1 ,4 ]
Zhao, Xihai [1 ]
van Osch, Matthias J. P. [2 ,3 ]
机构
[1] Tsinghua Univ, Dept Biomed Engn, Ctr Biomed Imaging Res, Beijing, Peoples R China
[2] Leiden Univ, Dept Radiol, Med Ctr, CJ Gorter Ctr High Field MRI, Leiden, Netherlands
[3] Leiden Inst Brain & Cognit, Leiden, Netherlands
[4] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
基金
中国国家自然科学基金;
关键词
pseudocontinuous; arterial spin labeling (ASL); perfusion imaging; labeling efficiency; MRI; BLOOD-FLOW; MRI; PERFUSION; BRAIN; RELIABILITY; INVERSION; ADULTS;
D O I
10.1002/mrm.26266
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeOptimization and validation of a sequence for measuring the labeling efficiency of pseudocontinuous arterial spin labeling (pCASL) perfusion MRI. MethodsThe proposed sequence consists of a labeling module and a single slice Look-Locker echo planar imaging readout. A model-based algorithm was used to calculate labeling efficiency from the signal acquired from the main brain-feeding arteries. Stability of the labeling efficiency measurement was evaluated with regard to the use of cardiac triggering, flow compensation and vein signal suppression. Accuracy of the measurement was assessed by comparing the measured labeling efficiency to mean brain pCASL signal intensity over a wide range of flip angles as applied in the pCASL labeling. ResultsSimulations show that the proposed algorithm can effectively calculate labeling efficiency when correcting for T1 relaxation of the blood spins. Use of cardiac triggering and vein signal suppression improved stability of the labeling efficiency measurement, while flow compensation resulted in little improvement. The measured labeling efficiency was found to be linearly (R=0.973; P<0.001) related to brain pCASL signal intensity over a wide range of pCASL flip angles. ConclusionThe optimized labeling efficiency sequence provides robust artery-specific labeling efficiency measurement within a short acquisition time (approximate to 30 s), thereby enabling improved accuracy of pCASL CBF quantification. Magn Reson Med 77:1841-1852, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine Magn Reson Med 77:1841-1852, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1841 / 1852
页数:12
相关论文
共 23 条
[1]   Basal Hippocampal Activity and Its Functional Connectivity Predicts Cocaine Relapse [J].
Adinoff, Bryon ;
Gu, Hong ;
Merrick, Carmen ;
McHugh, Meredith ;
Jeon-Slaughter, Haekyung ;
Lu, Hanzhang ;
Yang, Yihong ;
Stein, Elliot A. .
BIOLOGICAL PSYCHIATRY, 2015, 78 (07) :496-504
[2]   Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia [J].
Alsop, David C. ;
Detre, John A. ;
Golay, Xavier ;
Guenther, Matthias ;
Hendrikse, Jeroen ;
Hernandez-Garcia, Luis ;
Lu, Hanzhang ;
MacIntosh, Bradley J. ;
Parkes, Laura M. ;
Smits, Marion ;
van Osch, Matthias J. P. ;
Wang, Danny J. J. ;
Wong, Eric C. ;
Zaharchuk, Greg .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) :102-116
[3]   Estimation of Labeling Efficiency in Pseudocontinuous Arterial Spin Labeling [J].
Aslan, Sina ;
Xu, Feng ;
Wang, Peiying L. ;
Uh, Jinsoo ;
Yezhuvath, Uma S. ;
van Osch, Matthias ;
Lu, Hanzhang .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :765-771
[4]   Arterial Spin Labeling Versus Bolus-Tracking Perfusion in Hyperacute Stroke [J].
Bivard, Andrew ;
Krishnamurthy, Venkatesh ;
Stanwell, Peter ;
Levi, Christopher ;
Spratt, Neil J. ;
Davis, Stephen ;
Parsons, Mark .
STROKE, 2014, 45 (01) :127-133
[5]   Separation of Macrovascular Signal in Multi-inversion Time Arterial Spin Labelling MRI [J].
Chappell, Michael A. ;
MacIntosh, Bradley J. ;
Donahue, Manus J. ;
Guenther, Matthias ;
Jezzard, Peter ;
Woolrich, Mark W. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) :1357-1365
[6]   Test-Retest Reliability of Arterial Spin Labeling With Common Labeling Strategies [J].
Chen, Yufen ;
Wang, Danny J. J. ;
Detre, John A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) :940-949
[7]   Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields [J].
Dai, Weiying ;
Garcia, Dairon ;
de Bazelaire, Cedric ;
Alsop, David C. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1488-1497
[8]   Applications of arterial spin labeled MRI in the brain [J].
Detre, John A. ;
Rao, Hengyi ;
Wang, Danny J. J. ;
Chen, Yu Fen ;
Wang, Ze .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (05) :1026-1037
[9]  
Dolui S, 2014, P 22 ANN M ISMRM MIL
[10]   Vessel-Encoded Arterial Spin Labeling (VE-ASL) Reveals Elevated Flow Territory Asymmetry in Older Adults With Substandard Verbal Memory Performance [J].
Donahue, Manus J. ;
Hussey, Erin ;
Rane, Swati ;
Wilson, Tracy ;
van Osch, Matthias ;
Hartkamp, Nolan ;
Hendrikse, Jeroen ;
Ally, Brandon A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) :377-386