Evaluation of new automated gated-SPECT and echocardiographic methods for calculating left ventricular volumes and ejection fraction

被引:2
作者
Gjertsson, Peter [1 ]
Ekberg, Sofia [1 ]
Lomsky, Milan [1 ]
Gan, Li-Ming [1 ]
Edenbrandt, Lars [1 ]
机构
[1] Sahlgrens Univ Hosp, Dept Clin Physiol, SE-41345 Gothenburg, Sweden
关键词
Myocardial perfusion scintigraphy; Echocardiography; Left ventricular volumes; Left ventricular ejection fraction; Automated method; MYOCARDIAL-PERFUSION SPECT; EMISSION COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; 2-DIMENSIONAL ECHOCARDIOGRAPHY; RADIONUCLIDE VENTRICULOGRAPHY; QUANTIFICATION; VALIDATION; IMAGES; ACCURACY; QGS;
D O I
10.1016/j.ijcard.2008.04.082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left ventricular (LV) volumes and ejection fraction (LVEF) are assessed using ECG-gated myocardial perfusion scintigraphy (MPS) and echocardiography. We have developed CAFU, a new automated method for the quantification of MPS images. AutoEF software is a new automated method for quantifying echocardiograms (Tomtec research arena). The aim of the study was to compare these new methods with standard methods. Methods: Patients undergoing clinical MPS were invited to an echocardiographic examination. Eighty-eight patients were included, mean age 64 +/- 10 years, 50% men. LV volumes and LVEF from the echocardiographic examinations were calculated using the AutoEF software and calculations according to Simpson's rule. The LV volumes and LVEF from the MPS images were calculated using CAFU, Quantitative gated-SPECT (QGS) and Emory Cardiac Toolbox (ECT). Results: The MPS methods revealed larger LV volumes and LVEF compared with the echocardiographic methods. CAFU showed an excellent correlation with QGS and ECT (0.91-0.99). The correlations between the MPS and the echocardiographic methods (0.47-0.88), as well as between the AutoEF-assessed values and Simpson's method (0.57-0.87), were lower, however statistically significant. The correlations between the methods were higher for LV volumes than for LVEF. Conclusion: There was better agreement between LV volumes and LVEF values from the three MPS methods than between those from the two echocardiographic methods. The echocardiographic methods produced significantly lower LV volumes and LVEF compared with the MPS methods. In the clinical situation, LV volumes and LVEF values from different types of examination or different software packages should be treated with caution. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 50 条
[41]   Performance of 3-Dimensional Echocardiography in Measuring Left Ventricular Volumes and Ejection Fraction [J].
Dorosz, Jennifer L. ;
Lezotte, Dennis C. ;
Weitzenkamp, David A. ;
Allen, Larry A. ;
Salcedo, Ernesto E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (20) :1799-1808
[42]   A correlative study comparing current different methods of calculating left ventricular ejection fraction [J].
Gholamrezanezhad, Ali ;
Mirpour, Sahar ;
Esfehani, Armaghan F. ;
Saghari, Mohsen ;
Mirpour, Koorosh ;
Beiki, Davood ;
Soheilifar, Maryam .
NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (01) :41-48
[43]   Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular volumes and ejection fraction in patients with idiopathic dilated cardiomyopathy [J].
Sipola, Petri ;
Peuhkurinen, Keijo ;
Vanninen, Esko .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (04) :629-634
[44]   New hybrid count- and geometry-based method for quantification of left ventricular volumes and ejection fraction from ECG-gated SPECT: methodology and validation [J].
Yi-Hwa Liu ;
Albert J. Sinusas ;
Daniel Khaimov ;
Beata I. Gebuza ;
Frans J. Th. Wackers .
Journal of Nuclear Cardiology, 2005, 12 :55-65
[45]   Variability of serial same-day left ventricular ejection fraction using quantitative gated spect [J].
Enrique Vallejo ;
Hugo Chaya ;
Gerardo Plancarte ;
Diana Victoria ;
David Bialostozky .
Journal of Nuclear Cardiology, 2002, 9 :377-384
[46]   New hybrid count- and geometry-based method for quantification of left ventricular volumes and ejection fraction from ECG-gated SPECT: Methodology and validation [J].
Liu, YH ;
Sinusas, AJ ;
Khaimov, D ;
Gebuza, BI ;
Wackers, FJT .
JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (01) :55-65
[47]   Comparison of prone and supine determination of left ventricular ejection fraction measured by gated myocardial SPECT. [J].
Papathanassiou, D ;
Liehn, JC ;
Wampach, H ;
Perault, C ;
Ouzan, J ;
Pron, T ;
Dedienne, B ;
Bouchard, A .
MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 1997, 21 (8-9) :458-461
[48]   Variability of serial same-day left ventricular ejection fraction using quantitative gated SPECT [J].
Vallejo, E ;
Chaya, H ;
Plancarte, G ;
Victoria, D ;
Bialostozky, D .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (04) :377-384
[49]   Impact of a decrease in recorded counts on the left ventricular ejection fraction measurement from the D-SPECT camera [J].
Tissot, H. ;
Morel, O. ;
Imbert, L. ;
Roch, V. ;
Claudin, M. ;
Perrin, M. ;
Verger, A. ;
Karcher, G. ;
Marie, P. -Y. .
MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2017, 41 (02) :83-92
[50]   Assessment of left ventricular volumes, ejection fraction and mass Comparison of model-based analysis of ECG-gated 99mTc-SPECT and 18F-FDG-PET [J].
Khorsand, A. ;
Gyoengyoesi, M. ;
Sochor, H. ;
Maurer, G. ;
Karanikas, G. ;
Dudczak, R. ;
Schuster, E. ;
Porenta, G. ;
Graf, S. .
NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2011, 50 (01) :9-14