Evaluation of new automated gated-SPECT and echocardiographic methods for calculating left ventricular volumes and ejection fraction

被引:2
作者
Gjertsson, Peter [1 ]
Ekberg, Sofia [1 ]
Lomsky, Milan [1 ]
Gan, Li-Ming [1 ]
Edenbrandt, Lars [1 ]
机构
[1] Sahlgrens Univ Hosp, Dept Clin Physiol, SE-41345 Gothenburg, Sweden
关键词
Myocardial perfusion scintigraphy; Echocardiography; Left ventricular volumes; Left ventricular ejection fraction; Automated method; MYOCARDIAL-PERFUSION SPECT; EMISSION COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; 2-DIMENSIONAL ECHOCARDIOGRAPHY; RADIONUCLIDE VENTRICULOGRAPHY; QUANTIFICATION; VALIDATION; IMAGES; ACCURACY; QGS;
D O I
10.1016/j.ijcard.2008.04.082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left ventricular (LV) volumes and ejection fraction (LVEF) are assessed using ECG-gated myocardial perfusion scintigraphy (MPS) and echocardiography. We have developed CAFU, a new automated method for the quantification of MPS images. AutoEF software is a new automated method for quantifying echocardiograms (Tomtec research arena). The aim of the study was to compare these new methods with standard methods. Methods: Patients undergoing clinical MPS were invited to an echocardiographic examination. Eighty-eight patients were included, mean age 64 +/- 10 years, 50% men. LV volumes and LVEF from the echocardiographic examinations were calculated using the AutoEF software and calculations according to Simpson's rule. The LV volumes and LVEF from the MPS images were calculated using CAFU, Quantitative gated-SPECT (QGS) and Emory Cardiac Toolbox (ECT). Results: The MPS methods revealed larger LV volumes and LVEF compared with the echocardiographic methods. CAFU showed an excellent correlation with QGS and ECT (0.91-0.99). The correlations between the MPS and the echocardiographic methods (0.47-0.88), as well as between the AutoEF-assessed values and Simpson's method (0.57-0.87), were lower, however statistically significant. The correlations between the methods were higher for LV volumes than for LVEF. Conclusion: There was better agreement between LV volumes and LVEF values from the three MPS methods than between those from the two echocardiographic methods. The echocardiographic methods produced significantly lower LV volumes and LVEF compared with the MPS methods. In the clinical situation, LV volumes and LVEF values from different types of examination or different software packages should be treated with caution. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 50 条
[31]   COMPARISON OF LEFT VENTRICULAR VOLUMES AND EJECTION FRACTION ASSESSMENT BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH GATED MYOCARDIAL SPECT IN PATIENTS WITH ISCHEMIC CARDIOMYOPATHY [J].
Hutyra, Martin ;
Skala, Tomas ;
Kaminek, Milan ;
Zapletalova, Jana .
BIOMEDICAL PAPERS-OLOMOUC, 2010, 154 (01) :47-54
[32]   Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods [J].
Tracy L. Faber ;
Johnathan P. Vansant ;
Roderic I. Pettigrew ;
James R. Galt ;
Michel Blais ;
George Chatzimavroudis ;
C. David Cooke ;
Russell D. Folks ;
Sandra M. Waldrop ;
Elzbieta Gurtler-Krawczynska ;
Mark D. Wittry ;
Ernest V. Garcia .
Journal of Nuclear Cardiology, 2001, 8 :645-651
[33]   Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods [J].
Faber, TL ;
Vansant, JP ;
Pettigrew, RI ;
Galt, JR ;
Blais, M ;
Chatzimavroudis, G ;
Cooke, CD ;
Folks, RD ;
Waldrop, SM ;
Gurtler-Krawczynska, E ;
Wittry, MD ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) :645-651
[34]   A comparison of 8 and 16 frames gated SPECT imaging for determination of left ventricular volumes and ejection fraction: effects of gender and myocardial counts [J].
Mazinani, Mahdi ;
Tajik-Mansoury, Mohammad Ali ;
Sabour, Mahsa ;
Jadidi, Majid .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (06) :2079-2084
[35]   A comparison of 8 and 16 frames gated SPECT imaging for determination of left ventricular volumes and ejection fraction: effects of gender and myocardial counts [J].
Mahdi Mazinani ;
Mohammad Ali Tajik-Mansoury ;
Mahsa Sabour ;
Majid Jadidi .
The International Journal of Cardiovascular Imaging, 2021, 37 :2079-2084
[36]   Comparison of software programs for the assessment of left ventricular ejection fraction using 99mTc-tetrofosmin-gated SPECT/CT: correlation with equilibrium radionuclide ventriculography in the Indian population [J].
Ballal, Sanjana ;
Patel, Chetan D. ;
Singla, Suhas ;
Sharma, Punit ;
Narang, Rajiv ;
Sharma, Gautam ;
Malhotra, Arun .
NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) :1160-1168
[37]   Left ventricular aneurysm in the scope of gated perfusion SPECT: accuracy of detection and ejection fraction calculation [J].
Fevziye Canbaz ;
Tarik Basoglu ;
Kenan Durna ;
Sibel Ucak Semirgin ;
Sevgi Canbaz .
The International Journal of Cardiovascular Imaging, 2008, 24 :585-596
[38]   Left ventricular aneurysm in the scope of gated perfusion SPECT: accuracy of detection and ejection fraction calculation [J].
Canbaz, Fevziye ;
Basoglu, Tarik ;
Durna, Kenan ;
Semirgin, Sibel Ucak ;
Canbaz, Sevgi .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (06) :585-596
[39]   Effect of gender on cardiovascular risk stratification with ECG gated SPECT left ventricular volume indices and ejection fraction [J].
Wexler, Orren ;
Yoder, Scott R. ;
Elder, Jessica L. ;
Mackin, Maria L. ;
Chen, Leway ;
Mixon, Lonnie ;
Schwartz, Ronald G. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (01) :28-37
[40]   Comparison of left ventricular ejection fraction calculation methods [J].
Wilson, DJ ;
North, N ;
Wilson, RA .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (08) :709-712