Evaluation of new automated gated-SPECT and echocardiographic methods for calculating left ventricular volumes and ejection fraction

被引:2
作者
Gjertsson, Peter [1 ]
Ekberg, Sofia [1 ]
Lomsky, Milan [1 ]
Gan, Li-Ming [1 ]
Edenbrandt, Lars [1 ]
机构
[1] Sahlgrens Univ Hosp, Dept Clin Physiol, SE-41345 Gothenburg, Sweden
关键词
Myocardial perfusion scintigraphy; Echocardiography; Left ventricular volumes; Left ventricular ejection fraction; Automated method; MYOCARDIAL-PERFUSION SPECT; EMISSION COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; 2-DIMENSIONAL ECHOCARDIOGRAPHY; RADIONUCLIDE VENTRICULOGRAPHY; QUANTIFICATION; VALIDATION; IMAGES; ACCURACY; QGS;
D O I
10.1016/j.ijcard.2008.04.082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left ventricular (LV) volumes and ejection fraction (LVEF) are assessed using ECG-gated myocardial perfusion scintigraphy (MPS) and echocardiography. We have developed CAFU, a new automated method for the quantification of MPS images. AutoEF software is a new automated method for quantifying echocardiograms (Tomtec research arena). The aim of the study was to compare these new methods with standard methods. Methods: Patients undergoing clinical MPS were invited to an echocardiographic examination. Eighty-eight patients were included, mean age 64 +/- 10 years, 50% men. LV volumes and LVEF from the echocardiographic examinations were calculated using the AutoEF software and calculations according to Simpson's rule. The LV volumes and LVEF from the MPS images were calculated using CAFU, Quantitative gated-SPECT (QGS) and Emory Cardiac Toolbox (ECT). Results: The MPS methods revealed larger LV volumes and LVEF compared with the echocardiographic methods. CAFU showed an excellent correlation with QGS and ECT (0.91-0.99). The correlations between the MPS and the echocardiographic methods (0.47-0.88), as well as between the AutoEF-assessed values and Simpson's method (0.57-0.87), were lower, however statistically significant. The correlations between the methods were higher for LV volumes than for LVEF. Conclusion: There was better agreement between LV volumes and LVEF values from the three MPS methods than between those from the two echocardiographic methods. The echocardiographic methods produced significantly lower LV volumes and LVEF compared with the MPS methods. In the clinical situation, LV volumes and LVEF values from different types of examination or different software packages should be treated with caution. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 50 条
[21]   CMR validation of left ventricular volumes and ejection fraction measured by the IQ-SPECT system in patients with small heart size [J].
Wei, Hua ;
Wu, Jiaojiao ;
Han, Ke ;
Hu, Guang ;
Wang, Hongliang ;
Guo, Xiaoshan ;
Liu, Haiyan ;
Wu, Zhifang ;
Li, Sijin .
EJNMMI RESEARCH, 2023, 13 (01)
[22]   Gated Myocardial Perfusion SPECT: Algorithm-Specific Influence of Reorientation on Calculation of Left Ventricular Volumes and Ejection Fraction [J].
Knollmann, Daniela ;
Winz, Oliver H. ;
Meyer, Philipp T. ;
Raptis, Mardjan ;
Krohn, Thomas ;
Koch, Karl-Christian ;
Schaefer, Wolfgang M. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (10) :1636-1642
[23]   Potential Impact of SPECT Resolution on Quantification of Left Ventricular Volumes and Ejection Fraction: A Phantom Study [J].
Liu, Hui ;
Aslan, Mehmet ;
Sandoval, Veronica ;
Liu, Yi-Hwa .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2022, 42 (05) :734-743
[24]   Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging [J].
Leva, Lucia ;
Matheoud, Roberta ;
Sacchetti, Gianmauro ;
Carriero, Alessandro ;
Brambilla, Marco .
JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (05) :1714-1724
[25]   Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies [J].
Giulia Montelatici ;
Roberto Sciagrà ;
Alessandro Passeri ;
Manjola Dona ;
Alberto Pupi .
European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 :2059-2065
[26]   Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies [J].
Montelatici, Giulia ;
Sciagra, Roberto ;
Passeri, Alessandro ;
Dona, Manjola ;
Pupi, Alberto .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (11) :2059-2065
[27]   Left ventricular volumes and ejection fraction quantification using an automated three-dimensional adaptive analytic echocardiographic algorithm in pediatric population [J].
Carvajal-Rivera, Jose J. ;
Lopez-Quintero, Johanna C. ;
Gonzalez-Menchen, Cristina ;
Alberto de Agustin, Jose ;
Macaya, Carlos ;
Perez de Isla, Leopoldo .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (11) :1827-1834
[28]   Assessment of left ventricular volume and ejection fraction: comparison of QGS and MBGS analyses of ECG-gated myocardial perfusion SPECT imaging [J].
Khorsand, Aliasghar ;
Gyoengyoesi, Mariann ;
Graf, Senta ;
Zamini, Sholeh ;
Schuster, Ernst ;
Sochor, Heinz ;
Porenta, Gerold .
NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (04) :300-307
[29]   Three-dimensional echocardiographic acquisition and validity of left ventricular volumes and ejection fraction [J].
Jenkins, Carly ;
Tsang, Wendy .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (10) :1646-1653
[30]   Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction [J].
Vanhove, C ;
Walgraeve, N ;
De Geeter, F ;
Franken, PR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (06) :735-741