Cardiorenal 23Na MRI at 7.0 Tesla using a 4/4 channel 1H/23Na RF antenna array

被引:17
|
作者
Boehmert, Laura [1 ]
Kuehne, Andre [2 ]
Waiczies, Helmar [2 ]
Wenz, Daniel [1 ]
Eigentler, Thomas Wilhelm [1 ]
Funk, Stephanie [3 ]
von Knobelsdorff-Brenkenhoff, Florian [3 ,4 ]
Schulz-Menger, Jeanette [3 ,5 ]
Nagel, Armin M. [6 ,7 ,8 ]
Seeliger, Erdmann [9 ]
Niendorf, Thoralf [1 ,2 ,5 ,10 ]
机构
[1] Helmholtz Assoc, Max Delbruck Ctr Mol Med, BUFF, Berlin, Germany
[2] MRI TOOLS GmbH, Berlin, Germany
[3] Charite Med Fac & Max Delbruck Ctr Mol Med Helios, Expt & Clin Res Ctr, Working Grp Cardiovasc Magnet Resonance, Berlin, Germany
[4] Ludwig Maximilians Univ Munchen, Acad Teaching Hosp, Clin Agatharied, Dept Cardiol, Hausham, Germany
[5] DZHK German Ctr Cardiovasc Res, Partner Site Berlin, Berlin, Germany
[6] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Inst Radiol, Erlangen, Germany
[7] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
[8] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Erlangen, Inst Med Phys, Erlangen, Germany
[9] Charite, Inst Vegetat Physiol, Berlin, Germany
[10] Charite Med Fac & Max Delbruck Ctr Mol Med, Expt & Clin Res Ctr, Berlin, Germany
关键词
cardiac MRI; cardiorenal syndrome; MRI; renal MRI; RF coil; sodium; SODIUM MRI; 7; T; HUMAN HEART; MYOCARDIAL-INFARCTION; CARDIOVASCULAR MRI; HUMAN KIDNEYS; TIME-COURSE; COIL; DESIGN; CARTILAGE;
D O I
10.1002/mrm.27880
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Cardiorenal syndrome describes disorders of the heart and the kidneys in which a dysfunction of 1 organ induces a dysfunction in the other. This work describes the design, evaluation, and application of a 4/4-channel hydrogen-1/sodium (H-1/Na-23) RF array tailored for cardiorenal MRI at 7.0 Tesla (T) for a better physiometabolic understanding of cardiorenal syndrome. Methods The dual-frequency RF array is composed of a planar posterior section and a modestly curved anterior section, each section consisting of 2 loop elements tailored for Na-23 MR and 2 loopole-type elements customized for H-1 MR. Numerical electromagnetic field and specific absorption rate simulations were carried out. Transmission field (B1+) uniformity was optimized and benchmarked against electromagnetic field simulations. An in vivo feasibility study was performed. Results The proposed array exhibits sufficient RF characteristics, B1+ homogeneity, and penetration depth to perform Na-23 MRI of the heart and kidney at 7.0 T. The mean B1+ field for sodium in the heart is 7.7 +/- 0.8 mu T/root kW and in the kidney is 6.9 +/- 2.3 mu T/root kW. The suitability of the RF array for Na-23 MRI was demonstrated in healthy subjects (acquisition time for Na-23 MRI: 18 min; nominal isotropic spatial resolution: 5 mm [kidney] and 6 mm [heart]). Conclusion This work provides encouragement for further explorations into densely packed multichannel transceiver arrays tailored for Na-23 MRI of the heart and kidney. Equipped with this technology, the ability to probe sodium concentration in the heart and kidney in vivo using Na-23 MRI stands to make a critical contribution to deciphering the complex interactions between both organs.
引用
收藏
页码:2343 / 2356
页数:14
相关论文
共 50 条
  • [11] Simultaneous 3D acquisition of 1H MRF and 23Na MRI
    Yu, Zidan
    Hodono, Shota
    Dergachyova, Olga
    Hilbert, Tom
    Wang, Bili
    Zhang, Bei
    Brown, Ryan
    Sodickson, Daniel K.
    Madelin, Guillaume
    Cloos, Martijn A.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2299 - 2312
  • [12] Quantitative 1H and 23Na muscle MRI in Facioscapulohumeral muscular dystrophy patients
    Teresa Gerhalter
    Benjamin Marty
    Lena V. Gast
    Katharina Porzelt
    Rafael Heiss
    Michael Uder
    Stefan Schwab
    Pierre G. Carlier
    Armin M. Nagel
    Matthias Türk
    Journal of Neurology, 2021, 268 : 1076 - 1087
  • [13] Volume metasolenoid-based coil for 23Na MRI at 7 Tesla
    Solomakha, G.
    Hurshkainen, A.
    Glybovski, S.
    Andreychenko, A.
    METANANO 2019, 2020, 1461
  • [14] A dual-tuned multichannel bilateral RF coil for 1H/23Na breast MRI at 7 T
    Ianniello, Carlotta
    Madelin, Guillaume
    Moy, Linda
    Brown, Ryan
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1566 - 1575
  • [15] Feasibility study of a double resonant (1H/23Na) abdominal RF setup at 3 T
    Malzacher, Matthias
    Chacon-Caldera, Jorge
    Paschke, Nadia
    Schad, Lothar R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (04): : 359 - 367
  • [16] 23Na and 1H NMR Relaxometry of Shale at High Magnetic Field
    Yang, Donghan
    Kausik, Ravinath
    ENERGY & FUELS, 2016, 30 (06) : 4509 - 4519
  • [17] Optimization and Characterization of Sodium MRI Using 8-channel 23Na and 2-channel 1H RX/TX Coil
    James, J. R.
    Lin, C.
    Stark, H.
    Dale, B. M.
    Bansal, N.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 138 - +
  • [18] Iterative 3D Projection Reconstruction of 23Na Data with an 1H MRI Constraint
    Gnahm, Christine
    Bock, Michael
    Bachert, Peter
    Semmler, Wolfhard
    Behl, Nicolas G. R.
    Nagel, Armin M.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1720 - 1732
  • [19] Direct, longitudinal comparison of 1H and 23Na MRI after transient focal cerebral ischemia
    Lin, SP
    Song, SK
    Miller, JP
    Ackerman, JJH
    Neil, JJ
    STROKE, 2001, 32 (04) : 925 - 932
  • [20] Four-Dimensional 1H and 23Na Imaging Using Continuously Oscillating Gradients
    Center for Functional Imaging, Lawrence Berkeley Natl. Laboratory, MS 55-121, 1 Cyclotron Road, Berkeley, CA 94720, United States
    不详
    J. Magn. Reson., 2 (420-438):