Effective dose of radiation per screw in surgery of adolescent idiopathic scoliosis: matched pair analysis of 293 pedicle screws inserted using three different techniques

被引:6
作者
Konieczny, Markus Rafael [1 ]
Boos, Johannes [2 ]
Steuwe, Andrea [2 ]
Schleich, Christoph [2 ]
Prost, Max [1 ]
Krauspe, Ruediger [3 ]
机构
[1] Univ Hosp Duesseldorf, Dept Orthoped & Trauma Surg, Moorenstr 5, D-40225 Dusseldorf, Germany
[2] Univ Hosp Duesseldorf, Dept Radiol, Dusseldorf, Germany
[3] Univ Hosp Duesseldorf, Dept Orthoped Surg, Dusseldorf, Germany
关键词
adolescent idiopathic scoliosis; navigation; computer-assisted surgery; effective dose; pedicle screws; BEAM-COMPUTED-TOMOGRAPHY; IMAGE GUIDANCE; THORACIC SPINE; O-ARM; FLUOROSCOPY; PLACEMENT; EXPOSURE; NAVIGATION; ACCURACY; PRODUCT;
D O I
10.1302/1863-2548.14.200148
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Reports on heterogenous groups of patients have indicated that pedicle screw insertion guided by navigation (PIN) leads to, for the patient, higher doses of radiation compared with pedicle screw insertion guided by fluoroscopy (PIF). This would be a major concern, especially in paediatric deformity correction. Methods After a power analysis (aiming at > 0.8) 293 pedicle screws which were inserted in patients with adolescent idiopathic scoliosis were analyzed by comparing effective dose and fluoroscopy time per screw for three different techniques. Groups 2 and 3 were matched to Group 1 by Lenke type of scoliosis. Group 1 were prospectively enrolled consecutive patients that have been operated on by PIN with image acquisition by preoperative CT scan (CTS). Group 2 were consecutive retrospectively matched patients who have been operated on by PIN with image acquisition by an intraoperative 3D scan (3DS). Group 3 were consecutive retrospectively matched patients who have been operated on by PIF. Results Mean dose of radiation per screw was 1.0 mSv (sd 0.8) per screw in CTS patients, 0.025 mSv (sd 0.001) per screw in 3DS patients and 0.781 mSv (sd 0.12) per screw in PIF patients. The difference was significant (p < 0.0001). Conclusion When we compared different techniques of navigation, navigation by image acquisition with CTS showed a significantly higher (by 97.5%) dose of radiation per screw for the patient than navigation by image acquisition by a 3DS. Navigation by 3DS showed significantly lower effective dose per screw for the adolescent patients than the fluoroscopic technique.
引用
收藏
页码:554 / 561
页数:8
相关论文
共 24 条
  • [1] Doody MM, 2000, SPINE, V25, P2052
  • [2] G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
    Faul, Franz
    Erdfelder, Edgar
    Lang, Albert-Georg
    Buchner, Axel
    [J]. BEHAVIOR RESEARCH METHODS, 2007, 39 (02) : 175 - 191
  • [3] Statistical power analyses using G*Power 3.1: Tests for correlation and regression analyses
    Faul, Franz
    Erdfelder, Edgar
    Buchner, Axel
    Lang, Albert-Georg
    [J]. BEHAVIOR RESEARCH METHODS, 2009, 41 (04) : 1149 - 1160
  • [4] Conversion coefficients for estimation of effective dose to patients from dose area product during fluoroscopy X-ray examinations
    Gosch, D.
    Gosch, K.
    Kahn, T.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (10): : 1035 - 1042
  • [5] Intraoperative Computed Tomography Versus 3D C-Arm Imaging for Navigated Spinal Instrumentation
    Hecht, Nils
    Yassin, Hadya
    Czabanka, Marcus
    Foehre, Bettina
    Arden, Klaus
    Liebig, Thomas
    Vajkoczy, Peter
    [J]. SPINE, 2018, 43 (05) : 370 - 377
  • [6] CT effective dose per dose length product using ICRP 103 weighting factors
    Huda, Walter
    Magill, Dennise
    He, Wenjun
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1261 - 1265
  • [7] Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique
    Jin, Mengran
    Liu, Zhen
    Liu, Xingyong
    Yan, Huang
    Han, Xiao
    Qiu, Yong
    Zhu, Zezhang
    [J]. EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1729 - 1737
  • [8] Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study
    Kaminski, Ludovic
    Cordemans, V.
    Cartiaux, O.
    Van Cauter, M.
    [J]. EUROPEAN SPINE JOURNAL, 2017, 26 (11) : 2811 - 2817
  • [9] Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery
    Kim, Choll W.
    Lee, Yu-Po
    Taylor, William
    Oygar, Ahmet
    Kim, Woo Kyung
    [J]. SPINE JOURNAL, 2008, 8 (04) : 584 - 590
  • [10] Free hand pedicle screw placement in the thoracic spine: Is it safe?
    Kim, YJ
    Lenke, LG
    Bridwell, KH
    Cho, YSS
    Riew, KD
    [J]. SPINE, 2004, 29 (03) : 333 - 342