Empirical correlation development of R245fa flow in electronic expansion valves

被引:13
作者
Chen, Ting [1 ]
Bae, Kyung Jin [2 ]
Kwon, Oh Kyung [1 ,2 ]
机构
[1] Korea Univ Sci & Technol, Adv Energy & Technol, Korea Inst Ind Technol Campus, Cheonan 31056, South Korea
[2] Korea Inst Ind Technol, Thermal & Fluid Syst Grp, Cheonan 31056, South Korea
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2018年 / 88卷
关键词
Electronic expansion valves; R245fa refrigerant; Empirical correlation; ARTIFICIAL NEURAL-NETWORK; PUMP WATER-HEATER; ALTERNATIVE REFRIGERANTS; GENERALIZED CORRELATION; R410A; R407C; R22; PERFORMANCE; SIMULATION; SYSTEM;
D O I
10.1016/j.ijrefrig.2018.01.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
The applications of electronic expansion valves in high temperature heat pump have increased rapidly. However, correlations for predicting R245fa mass flow rate through electronic expansion valves in high temperature heat pump are very limited in open literatures. In this study, mass flow rate characteristics of R245fa refrigerant flowing through electronic expansion valves with different operational conditions are studied experimentally, and empirical correlations are proposed based on the experimental data. The results reveal that the mass flow rate increases with increasing opening degree, condensation temperature, subcooling, and orifice diameter. Based on a modified single phase orifice equation, two empirical correlations are proposed by using the power-law correlation and the polynomial fit correlation, and over 92% of the predicted data deviate from the experimental data within +/- 15%. (C) 2018 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:284 / 290
页数:7
相关论文
共 29 条
[1]  
American National Standard, 2002, 6053421 IEC
[2]  
[Anonymous], 2002, ASHRAE HDB REFR
[3]   Refrigerant flow through electronic expansion valve: Experiment and neural network modeling [J].
Cao, Xiang ;
Li, Ze-Yu ;
Shao, Liang-Liang ;
Zhang, Chun-Lu .
APPLIED THERMAL ENGINEERING, 2016, 92 :210-218
[4]  
Cengel Y. A., 2013, THERMODYNAMICS ENG A, P223
[5]   Experimental investigation on mass flow characteristics of electronic expansion valves with R22, R410A and R407C [J].
Chen Liang ;
Chen Jiangping ;
Liu Jinghui ;
Chen Zhijiu .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (04) :1033-1039
[6]   A new model of mass flow characteristics in electronic expansion valves considering metastability [J].
Chen Liang ;
Liu Jinghui ;
Chen Jiangping ;
Chen Zhijiu .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (06) :1235-1242
[7]   Experimental investigation on mass flow characteristics of R245fa through electronic expansion valve [J].
Chen, Ting ;
Cha, Dong An ;
Kwon, Oh Kyung .
APPLIED THERMAL ENGINEERING, 2017, 125 :111-117
[8]   A generalized correlation for two-phase flow of alternative refrigerants through short tube orifices [J].
Choi, J ;
Chung, J ;
Kim, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04) :393-400
[9]   The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube [J].
Choi, JM ;
Kim, YC .
ENERGY, 2002, 27 (04) :391-404
[10]   Mass flowrate characteristics of supercritical CO2 flowing through an electronic expansion valve [J].
Hou, Yu ;
Liu, Changhai ;
Ma, Juanli ;
Cao, Jing ;
Chen, Shuangtao .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 47 :134-140