Effects of different air inlets on indoor air quality and ammonia emission from two experimental fattening pig rooms with partial pit ventilation system - Summer condition

被引:24
作者
Zong, Chao [1 ]
Feng, Ying [1 ,2 ]
Zhang, Guoqiang [1 ]
Hansen, Michael Jorgen [1 ]
机构
[1] Aarhus Univ, Dept Engn, DK-8830 Tjele, Denmark
[2] Beijing Agr Machinery Inst, Beijing 100083, Peoples R China
关键词
Partial pit air exhaust; Ventilation design and control; Emission reduction; Indoor airquality; Air purification unit; LIVESTOCK BUILDINGS; MANURE; MODEL; FLOOR; PATTERNS;
D O I
10.1016/j.biosystemseng.2014.04.005
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
It has previous been demonstrated that a pit ventilation system could improve indoor air quality and reduce ammonia emission significantly from pig production if an air purification system was installed to treat the pit exhaust air. However, the knowledge about the influence of a partial pit exhaust unit treating a small part of the ventilation (10%) in a ventilation system with different types of air inlets on indoor air quality and ammonia emission from pig house is still lacking. In this study, two rooms, both with partial pit exhaust and ceiling-top room exhaust units, were used. One room was equipped with ceiling air inlet (system C) and another room was equipped with wall jet air inlet (system W). Each room had 32 fattening pigs. The maximum ventilation rate in each room was set as 3200 m(3) h(-1). Room ventilation rate was automatically controlled by a climate control strategy based on indoor thermal conditions, while pit ventilation rate was fixed at 10% of the maximum ventilation rate. Ammonia concentrations were measured in air inlet, room exhaust and pit exhaust for both systems. Air flow rates and ammonia concentrations were measured and recorded continuously. Results showed that ventilation rate requirement was higher in system C than in system W (22.3%, p < 0.001) to maintain the setup indoor thermal condition during the whole fattening period. In the meantime, significant higher ammonia concentrations and emissions in both pit and room exhausts were found in system W than in system C (p < 0.001). The ammonia emission ratio of pit exhaust, defined as the emission via pit exhaust divided by the total emission, in systems C and W was 48% and 47%, respectively. If applying an effective air purification system, a significant reduction of ammonia emission could be achieved. The gap of ammonia concentration difference between system C and W increased in the later stage. Higher room ventilation rate led to smaller difference of ammonia concentration in room air. Slurry depth had a positive effect on the ammonia emission from pit exhaust. No significant difference in the pigs' activity was found between the two ventilation systems. (c) 2014 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:163 / 173
页数:11
相关论文
共 29 条
[1]   AMMONIA EMISSION PATTERNS DURING THE GROWING PERIODS OF PIGS HOUSED ON PARTIALLY SLATTED FLOORS [J].
AARNINK, AJA ;
KEEN, A ;
METZ, JHM ;
SPEELMAN, L ;
VERSTEGEN, MWA .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1995, 62 (02) :105-116
[2]  
Aarnink AJA, 1997, T ASAE, V40, P1161, DOI 10.13031/2013.21337
[3]  
Arogo J, 2003, T ASAE, V46, P805, DOI 10.13031/2013.13597
[4]   Mass transfer coefficient of ammonia in liquid swine manure and aqueous solutions [J].
Arogo, J ;
Zhang, RH ;
Riskowski, GL ;
Christianson, LL ;
Day, DL .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 73 (01) :77-86
[5]  
Bjerg Bjarne, 2011, Chemistry, Emission Control, Radioactive Pollution and Indoor Air Quality, P639
[6]  
Bjerg B., 2008, 8 ASABE INT LIV ENV
[7]  
Buiter JJ, 1998, T ASAE, V41, P1817, DOI 10.13031/2013.17335
[8]   On-site application of air cleaner emitting plasma ion to reduce airborne contaminants in pig building [J].
Cho, Man Su ;
Ko, Han Jong ;
Kim, Daekeun ;
Kim, Ki Youn .
ATMOSPHERIC ENVIRONMENT, 2012, 63 :276-281
[9]  
DEPRAETERE K, 1990, J AGR ENG RES, V46, P31, DOI 10.1016/S0021-8634(05)80047-2
[10]  
Gustafsson G., 1987, P SEM 2 TECHN SEC C