The Evaluation of Optimal Conditions for Constructing of Potentiometric Gadolinium Sensor using Experimental Design

被引:0
|
作者
Rajabi, Negar [1 ]
Masrournia, Mahboubeh [1 ]
Abedi, Mohamadreza [2 ]
机构
[1] Islamic Azad Univ, Mashhad Branch, Dept Chem, Mashhad, Razavi Khorasan, Iran
[2] Islamic Azad Univ, Quchan Branch, Dept Appl Chem, Quchan, Iran
来源
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY | 2019年 / 11卷 / 08期
关键词
Gd(III); Ortho phenylenediamine; Experimental design; Ion selective electrode; Multi-walled carbon nanotubes; CARBON-PASTE ELECTRODE; ION-SELECTIVE ELECTRODES; COMPOSITE; GLASSES;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, the synthetic ligand of ortho-phenylenediamine (C22H22N4O4) was used as an ionophore in the design and manufacture of Gd(III) ion selective carbon paste electrode. The D-optimal Mixture Design was used to investigate the effects of independent parameters and their correlations, for evaluating and optimizing of the components of the Gd(III) carbon paste electrodes. The Design-Expert (Plackett-Burman Design) software package Minitab ver. 17.0 optimized the composition of the membrane percentage of the proposed sensor. The experimental design method reduces of number of experiments and saving time and cost. Also consider simultaneously effect of factors on optimal condition, study non-linear relations and the interactions between factors is possible. The optimal components of the membrane included graphite powder 60.00%, paraffin oil 30.00%, ionophore 8.00%, and multiwall carbon nanotubes 2.00 %. Ion selective electrode show the Nernst slope of 19.08 mV/decade at a concentration range of 1.0x10(-2) to 1.0x1.0(-7) mol L-1, with the detection limit of 2.14 +/- 10(-8) mol L-1. The desired electrode has a response time of less than 15 seconds and relatively good lifetime in the pH 5-9 range. It can also be used in potentiometric titration of Gd(III) by EDTA.
引用
收藏
页码:1057 / 1069
页数:13
相关论文
共 50 条
  • [1] Employment of Optimal Mixture Design to Optimize Selective and Sensitive Manganese (II) Potentiometric Sensor in Environmental and Biological Samples
    Sanati, Mahnaz
    Shahinfar, Marjan
    Masrournia, Mahboubeh
    Behmadi, Hossein
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (06): : 428 - 443
  • [2] EVALUATION OF BIODIESEL PRODUCTION USING EXPERIMENTAL DESIGN
    Akgun, Nalan
    Dere, Gozde
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2007, 25 (03): : 259 - 267
  • [3] Potentiometric Determination of La(III) Using Chitosan Modified Carbon Paste Electrode with An experimental Design
    Rajabi, Negar
    Masrournia, Mahboubeh
    Abedi, Mohamadreza
    CHEMICAL METHODOLOGIES, 2020, 4 (05): : 660 - 670
  • [4] Development of a highly efficient gadolinium(III) potentiometric sensor using two aza-crown ether-based multiple diglycolamides (DGAs)
    Sharma, Dharmendra B.
    Mahanty, Bholanath
    Mohapatra, Prasanta K.
    Egberink, Richard J. M.
    Huskens, Jurriaan
    Verboom, Willem
    MICROCHEMICAL JOURNAL, 2023, 194
  • [5] Evaluation of the effect of experimental conditions on the total reductive capacity of extracts of lettuce through an experimental design
    Delgado, T.
    Ferreira, A.
    Pereira, J. A.
    Baptista, P.
    Casal, S.
    Ramalhosa, E.
    VII CONGRESO IBERICO DE AGROINGENIERIA Y CIENCIAS HORTICOLAS: INNOVAR Y PRODUCIR PARA EL FUTURO. INNOVATING AND PRODUCING FOR THE FUTURE, 2014, : 967 - 971
  • [6] Effect of different experimental parameters on the potentiometric evaluation of blood electrolytes using K+ as a test cation
    Oliveira, CMRR
    Rebelo, MJF
    Camoes, MFGF
    ANALYST, 1996, 121 (12) : 1907 - 1910
  • [7] Formulation and evaluation of o/w emulsions using experimental design
    Prinderre, P
    Piccerelle, P
    Cauture, E
    Kalantzis, G
    Reynier, JP
    Joachim, J
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1998, 163 (1-2) : 73 - 79
  • [8] Comparing design of experiments and optimal experimental design techniques for modelling the microbial growth rate under static environmental conditions
    Akkermans, Simen
    Nimmegeers, Philippe
    Van Impe, Jan F.
    FOOD MICROBIOLOGY, 2018, 76 : 504 - 512
  • [9] Optimization of the Experimental Conditions for the Stability of Nanofluids Using Box-Behnken Design
    Ma, Lin
    Yu, Zhiqiang
    Qing, Shan
    Liu, Yingchun
    Li, Zengen
    Gui, Zhao
    Zhang, Aimin
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2017, 9 (11) : 1724 - 1730
  • [10] Systematic approach for the evaluation of the optimal fabrication conditions of a H2S gas sensor with Taguchi method
    Kim, ST
    Park, MS
    Kim, HM
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 102 (02): : 253 - 260