Improved detection of echo signals from inside bone

被引:3
作者
Irie, T
Ohdaira, E
Ide, M
Itoh, K
Nagai, H
机构
[1] Musashi Inst Technol, Setagaya Ku, Tokyo 1588557, Japan
[2] Jichi Med Sch, Minami Kawachi, Tochigi 32904, Japan
[3] Nihon Kohden Corp, Shinjuku Ku, Tokyo 1618560, Japan
关键词
attenuation; bone; reflection method; standard reflector; ultrasound;
D O I
10.1016/S0041-624X(99)00161-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of the study was to obtain useful information for diagnosing internal abnormalities of bones by ultrasound. We fabricated a transmitting and receiving system mainly targeting the bone and an image processing system using a computer, and studied the attenuation of ultrasound in animal bone (in vitro). The average value was about 37 dB. The examination was able to determine successfully the proper dynamic range for detection, and a B-mode image of the inside of the bone could be displayed. Here we describe a new transmitting and receiving system developed to improve the detection of echo signals from inside bones. In this method, two kinds of high sensitivity transducer were made as follows: (1) 5 HMz frequency, 6.5 mm diameter; (2) 10 HMz frequency, 13 mm diameter. By using this method, detectability of the echo signals can be increased more than with the former system. The results showed that the structure of the bones could be clearly seen in the B-mode images. (C) 2000 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:698 / 702
页数:5
相关论文
共 50 条
  • [31] Detection of delamination defect inside timber by sonic IR
    Choi, M. Y.
    Park, J. H.
    Kim, W. T.
    Kang, K. S.
    THERMOSENSE XXX, 2008, 6939
  • [32] Diffuse reflectance spectroscopy of the spine: improved breach detection with angulated fibers
    Losch, Merle S.
    Kardux, Famke
    Dankelman, Jenny
    Hendriks, Benno H. W.
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (02) : 739 - 750
  • [33] Cluster-based segmentation of dual-echo ultra-short echo time images for PET/MR bone localization
    Delso G.
    Zeimpekis K.
    Carl M.
    Wiesinger F.
    Hüllner M.
    Veit-Haibach P.
    EJNMMI Physics, 1 (1) : 1 - 13
  • [34] Fast field echo resembling a CT using restricted echo-spacing (FRACTURE): a novel MRI technique with superior bone contrast
    Johnson, Brian
    Alizai, Hamza
    Dempsey, Molly
    SKELETAL RADIOLOGY, 2021, 50 (08) : 1705 - 1713
  • [35] Nerve Tissue Prefabrication Inside the Rat Femoral Bone: Does It Work?
    Ozbek, Zuhtu
    Kocman, Atacan Emre
    Ozatik, Orhan
    Soztutar, Erdem
    Ozkara, Emre
    Kose, Aydan
    Arslantas, Ali
    Cetin, Cengiz
    TURKISH NEUROSURGERY, 2017, 27 (04) : 648 - 655
  • [36] Fast field echo resembling a CT using restricted echo-spacing (FRACTURE): a novel MRI technique with superior bone contrast
    Brian Johnson
    Hamza Alizai
    Molly Dempsey
    Skeletal Radiology, 2021, 50 : 1705 - 1713
  • [37] Detection of Bone Density with Ultrasound
    Chen, Yanyan
    Xu, Yubing
    Ma, Zuchang
    Sun, Yining
    2010 SYMPOSIUM ON SECURITY DETECTION AND INFORMATION PROCESSING, 2010, 7 : 371 - 376
  • [38] Automated bone fracture detection
    Donnelley, M
    Knowles, G
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 955 - 966
  • [39] A composite material model for improved bone formation
    Scaglione, Silvia
    Lazzarini, Erica
    Ilengo, Cristina
    Quarto, Rodolfo
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2010, 4 (07) : 505 - 513
  • [40] Effect of trabecular bone material properties on ultrasonic backscattering signals
    LIU Chengcheng
    TA De’an
    WANG Weiqi
    Chinese Journal of Acoustics, 2014, 33 (01) : 73 - 82