MALDI-TOF MS identification of anaerobic bacteria: assessment of pre-analytical variables and specimen preparation techniques

被引:42
作者
Hsu, Yen-Michael S. [1 ]
Burnham, Carey-Ann D. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Pathol & Immunol, St Louis, MO 63110 USA
关键词
MALDI-TOF MS; Anaerobe; Anaerobic bacteria identification; extraction; DESORPTION IONIZATION-TIME; FLIGHT MASS-SPECTROMETRY; BACTEROIDES-FRAGILIS GROUP; ROUTINE IDENTIFICATION; MICROBIOLOGY;
D O I
10.1016/j.diagmicrobio.2014.02.007
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has emerged as a tool for identifying clinically relevant anaerobes. We evaluated the analytical performance characteristics of the Bruker Microflex with Biotyper 3.0 software system for identification of anaerobes and examined the impact of direct formic acid (FA) treatment and other pre-analytical factors on MALDI-TOF MS performance. A collection of 101 anaerobic bacteria were evaluated, including Clostridium spp., Propionibacterium spp., Fusobacterium spp., Bacteroides spp., and other anaerobic bacterial of clinical relevance. The results of our study indicate that an on-target extraction with 100% FA improves the rate of accurate identification without introducing misidentification (P < 0.05). In addition, we modify the reporting cutoffs for the Biotyper "score" yielding acceptable identification. We found that a score of >= 1.700 can maximize the rate of identification. Of interest, MALDI-TOF MS can correctly identify anaerobes grown in suboptimal conditions, such as on selective culture media and following oxygen exposure. In conclusion, we report on a number of simple and cost-effective pre- and post-analytical modifications could enhance MALDI-TOF MS identification for anaerobic bacteria. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:144 / 148
页数:5
相关论文
共 31 条
[1]   Anaerobic bacterial infection of the lung [J].
Bartlett, John G. .
ANAEROBE, 2012, 18 (02) :235-239
[2]   Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry as an Alternative to 16S rRNA Gene Sequencing for Identification of Difficult-To-Identify Bacterial Strains [J].
Bizzini, A. ;
Jaton, K. ;
Romo, D. ;
Bille, J. ;
Prod'hom, G. ;
Greub, G. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (02) :693-696
[3]   Performance of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Bacterial Strains Routinely Isolated in a Clinical Microbiology Laboratory [J].
Bizzini, A. ;
Durussel, C. ;
Bille, J. ;
Greub, G. ;
Prod'hom, G. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (05) :1549-1554
[4]   The role of anaerobic bacteria in bacteremia [J].
Brook, Itzhak .
ANAEROBE, 2010, 16 (03) :183-189
[5]   Clinical and Microbiological Characteristics of Perianal Infections in Adult Patients with Acute Leukemia [J].
Chen, Chien-Yuan ;
Cheng, Aristine ;
Huang, Shang-Yi ;
Sheng, Wang-Huei ;
Liu, Jia-Hau ;
Ko, Bo-Sheng ;
Yao, Ming ;
Chou, Wen-Chien ;
Lin, Hui-Chi ;
Chen, Yee-Chun ;
Tsay, Woei ;
Tang, Jih-Luh ;
Chang, Shan-Chwen ;
Tien, Hwei-Fang .
PLOS ONE, 2013, 8 (04)
[6]   Comparison of Two Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Methods with Conventional Phenotypic Identification for Routine Identification of Bacteria to the Species Level [J].
Cherkaoui, Abdessalam ;
Hibbs, Jonathan ;
Emonet, Stephane ;
Tangomo, Manuela ;
Girard, Myriam ;
Francois, Patrice ;
Schrenzel, Jacques .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (04) :1169-1175
[7]   Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Analysis of Gram-Positive, Catalase-Negative Cocci Not Belonging to the Streptococcus or Enterococcus Genus and Benefits of Database Extension [J].
Christensen, Jens Jorgen ;
Dargis, Rimtas ;
Hammer, Monja ;
Justesen, Ulrik Stenz ;
Nielsen, Xiaohui C. ;
Kemp, Michael .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (05) :1787-1791
[8]   Rapid Identification of Bacteria from Positive Blood Culture Bottles by Use of Matrix-Assisted Laser Desorption-Ionization Time of Flight Mass Spectrometry Fingerprinting [J].
Christner, Martin ;
Rohde, Holger ;
Wolters, Manuel ;
Sobottka, Ingo ;
Wegscheider, Karl ;
Aepfelbacher, Martin .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (05) :1584-1591
[9]   16S ribosomal DNA sequence analysis of a large collection of environmental and clinical unidentifiable bacterial isolates [J].
Drancourt, M ;
Bollet, C ;
Carlioz, A ;
Martelin, R ;
Gayral, JP ;
Raoult, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (10) :3623-3630
[10]  
El-Sharif A, 2012, FUTURE MICROBIOL, V7, P1423, DOI [10.2217/fmb.12.125, 10.2217/FMB.12.125]