Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer

被引:14
|
作者
Abe, Kota [1 ]
Kadoya, Noriyuki [1 ]
Sato, Shinya [1 ]
Hashimoto, Shimpei [2 ]
Nakajima, Yujiro [1 ,2 ]
Miyasaka, Yuya [1 ,3 ]
Ito, Kengo [1 ]
Umezawa, Rei [1 ]
Yamamoto, Takaya [1 ]
Takahashi, Noriyoshi [1 ]
Takeda, Ken [4 ]
Jingu, Keiichi [1 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Radiat Oncol, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9808574, Japan
[2] Komagome Hosp, Tokyo Metropolitan Canc & Infect Dis Ctr, Dept Radiat Oncol, Bunkyo Ku, 3-18-22 Honkomagome, Tokyo 1138677, Japan
[3] Yamagata Univ, Dept Radiat Oncol, Fac Med, 2-2-2 Iidani, Yamagata 9909585, Japan
[4] Tohoku Univ, Grad Sch Med, Dept Therapeut Radiol, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9808574, Japan
基金
日本学术振兴会;
关键词
radiotherapy; brachytherapy; model-based dose calculation algorithm; Monte Carlo simulation; cervical cancer; RATE INTRACAVITARY BRACHYTHERAPY; COLLAPSED CONE CONVOLUTION; DOSIMETRY PARAMETERS; TG-43; FORMALISM; RECOMMENDATIONS; RADIOTHERAPY; IR-192; APPLICATOR; PROTOCOL; THERAPY;
D O I
10.1093/jrr/rrx081
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We evaluated the impact of model-based dose calculation algorithms (MBDCAs) on high-dose-rate brachytherapy (HDR-BT) treatment planning for patients with cervical cancer. Seven patients with cervical cancer treated using HDR-BT were studied. Tandem and ovoid applicators were used in four patients, a vaginal cylinder in one, and interstitial needles in the remaining two patients. MBDCAs were applied to the Advanced Collapsed cone Engine (ACE; Elekta, Stockholm, Sweden). All plans, which were originally calculated using TG-43, were re-calculated using both ACE and Monte Carlo (MC) simulations. Air was used as the rectal material. The mean difference in the rectum D-2cm3 between ACE(rec-air) and MCrec-air was 8.60 +/- 4.64%, whereas that in the bladder D-2cm3 was - 2.80 +/- 1.21%. Conversely, in the small group analysis (n = 4) using water instead of air as the rectal material, the mean difference in the rectum D-2cm3 between TG-43 and ACE(rec-air) was 11.87 +/- 2.65%, whereas that between TG-43 and ACE(rec-water) was 0.81 +/- 2.04%, indicating that the use of water as the rectal material reduced the difference in D-2cm3 between TG-43 and ACE. Our results suggested that the differences in the dose-volume histogram (DVH) parameters of TG-43 and ACE were large for the rectum when considerable air (gas) volume was present in it, and that this difference was reduced when the air (gas) volume was reduced. Also, ACE exhibited better dose calculation accuracy than that of TG-43 in this situation. Thus, ACE may be able to calculate the dose more accurately than TG-43 for HDR-BT in treating cervical cancers, particularly for patients with considerable air (gas) volume in the rectum.
引用
收藏
页码:198 / 206
页数:9
相关论文
共 50 条
  • [11] Dose Delivered to the Lumbosacral Plexus From High-Dose-Rate Brachytherapy for Cervical Cancer
    Rash, Dominique
    Durbin-Johnson, Blythe
    Lim, Jihoon
    Dieterich, Sonja
    Huddleston, Adam
    Yi, Sun
    Mayadev, Jyoti
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2015, 25 (05) : 897 - 902
  • [12] Combined Interstitial and Intracavitary High-Dose Rate Brachytherapy of Cervical Cancer
    Itami, Jun
    Murakami, Naoya
    Watanabe, Miho
    Sekii, Shuhei
    Kasamatsu, Takahiro
    Kato, Shingo
    Hirowatari, Hisako
    Ikushima, Hitoshi
    Ando, Ken
    Ohno, Tatsuya
    Okamoto, Hiroyuki
    Okuma, Kae
    Igaki, Hiroshi
    FRONTIERS IN ONCOLOGY, 2022, 11
  • [14] Clinical Impact of Escalating Relative High-dose-rate Intracavitary Brachytherapy Dose in Stage IIB Cervical Cancer
    Cho, Oyeon
    Noh, O. Kyu
    Oh, Young-Taek
    Chang, Suk-Joon
    Chun, Mison
    ANTICANCER RESEARCH, 2017, 37 (01) : 327 - 334
  • [15] The impact of body mass index on rectal dose in locally advanced cervical cancer treated with high-dose-rate brachytherapy
    Lim, Jihoon
    Durbin-Johnson, Blythe
    Valicenti, Richard
    Mathai, Matthew
    Stem, Robin L.
    Mayadev, Jyoti
    BRACHYTHERAPY, 2013, 12 (06) : 550 - 554
  • [16] IMPACT OF OPTIMIZED TREATMENT PLANNING FOR TANDEM AND RING, AND TANDEM AND OVOIDS, USING HIGH-DOSE-RATE BRACHYTHERAPY FOR CERVICAL-CANCER
    NOYES, WR
    PETERS, NE
    THOMADSEN, BR
    FOWLER, JF
    BUCHLER, DA
    STITT, JA
    KINSELLA, TJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01): : 79 - 86
  • [17] A study of high-dose-rate intracavitary brachytherapy boost for curative treatment of uterine cervical cancer
    Okuma, Kae
    Yamashita, Hideomi
    Kobayashi, Reiko
    Nakagawa, Keiichi
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (02) : 128 - 134
  • [18] Biologic treatment planning for high-dose-rate brachytherapy
    Manning, MA
    Zwicker, RD
    Arthur, DW
    Arnfield, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 839 - 845
  • [19] High-dose-rate interstitial computed tomography-based brachytherapy for the treatment of cervical cancer: Early results
    Kannan, Neeta
    Beriwal, Sushil
    Kim, Hayeon
    Houser, Christopher
    Mogus, Robert
    Sukumvanich, Paniti
    Olawaiye, Alexander B.
    Richard, Scott
    Kelley, Joseph L.
    Edwards, Robert P.
    Krivak, Thomas C.
    BRACHYTHERAPY, 2012, 11 (05) : 408 - 412
  • [20] High-Dose-Rate Brachytherapy for the Treatment of Vaginal Intraepithelial Neoplasia
    Song, Jin Ho
    Lee, Joo Hwan
    Lee, Jong Hoon
    Park, Jong Sup
    Hong, Sook Hee
    Jang, Hong Seok
    Kim, Yeon Sil
    Choi, Byung Ock
    Yoon, Sei Chul
    CANCER RESEARCH AND TREATMENT, 2014, 46 (01): : 74 - 80