Improved quantification in 123I cardiac SPECT imaging with deconvolution of septal penetration

被引:14
作者
Chen, Ji
Garcia, Ernest V.
Galt, James R.
Folks, Russell D.
Carrio, Ignasi
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Hosp Santa Creu & Sant Pau, Barcelona, Spain
关键词
I-123; imaging; cardiac SPECT; quantification; septal penetration;
D O I
10.1097/00006231-200607000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives I-123 is becoming an important radionuclide for cardiac imaging. Multiple, low-abundance, high-energy photons associated with I-123 imaging can cause septal penetration in the collimators and degrade quantification of the I-123 cardiac uptake. This study presents a method for the deconvolution of septal penetration (DSP) for improving quantification in I-123 cardiac single photon emission computed tomography (SPECT). Methods Distance-dependent point spread functions were measured for low-energy high-resolution collimators on a dual-head SPECT system. The measured point spread functions were used in two-dimensional (2-D) and three-dimensional (3-D) models of the collimator response, respectively. 2-D DSP and 3-D DSP were then developed and implemented using iterative reconstruction. A cardiac torso phantom with an internal calibration source was designed with various heart-to-calibration ratios (HCRs) simulating different levels of a patient's uptake. SPECT acquisitions of the phantom were performed using optimized acquisition and processing parameters for I-123 cardiac SPECT. HCRs were calculated using planar projection and tomographic reconstructions. The paired Mest and regression analysis were used to compare the HCRs given by different calculation methods. Results SPECT produced more accurate HCRs than planar imaging. The slopes of the regression lines for SPECT using filtered back-projection were statistically significantly higher than those for planar imaging (0.2118 +/- 0.0297 vs. 0.0819 +/- 0.0070, P=0.0001). 2-D DSP and 3-D DSP yielded similar HCRs that were close to the true HCR. The slopes of the regression lines for 2-D DSP and 3-D DSP were 0.9203 +/- 0.0523 and 0.9101 +/- 0.0304, respectively. The DSP HCRs were significantly more accurate than those calculated without DSP (P < 0.0001). Conclusion DSP significantly improves quantification in I-123 cardiac SPECT imaging. 2-D DSP with its less computational burden shows promise for implementation in clinical practice so as to allow the use of the widely available low-energy, high-resolution collimators for quantitative I-123 cardiac SPECT imaging.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 27 条
  • [1] OBJECT SHAPE DEPENDENT PSF MODEL FOR SPECT IMAGING
    BEEKMAN, FJ
    EIJKMAN, EGJ
    VIERGEVER, MA
    BORM, GF
    SLIJPEN, ETP
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (01) : 31 - 39
  • [2] IMAGING I-123 WITH A SCINTILLATION CAMERA - STUDY OF DETECTION PERFORMANCE AND QUALITY FACTOR CONCEPTS
    BOLMSJO, MS
    PERSSON, BRR
    STRAND, SE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (02) : 266 - 277
  • [3] Optimized acquisition and processing protocols for 1-123 cardiac SPECT imaging
    Chen, J
    Garcia, EV
    Galt, JR
    Folks, RD
    Carrio, I
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (02) : 251 - 260
  • [4] Optimal collimator choice for sequential iodine-123 and technetium-99m imaging
    DeGeeter, F
    Franken, PR
    Defrise, M
    Andries, H
    Saelens, E
    Bossuyt, A
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (07): : 768 - 774
  • [5] Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators:: consequences for imaging with 123I-labelled compounds in clinical practice
    Dobbeleir, AA
    Hambye, ASE
    Franken, PR
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (06) : 655 - 658
  • [6] Dobbeleir AA, 1999, J NUCL MED, V40, P707
  • [7] Fleming JS, 1996, J NUCL MED, V37, P1832
  • [8] COMPENSATION FOR COLLIMATOR DIVERGENCE IN SPECT USING INVERSE MONTE-CARLO RECONSTRUCTION
    FLOYD, CE
    JASZCZAK, RJ
    MANGLOS, SH
    COLEMAN, RE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 784 - 787
  • [9] COMPENSATION OF SPATIAL SYSTEM RESPONSE IN SPECT WITH CONJUGATE-GRADIENT RECONSTRUCTION TECHNIQUE
    FORMICONI, AR
    PUPI, A
    PASSERI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (01) : 69 - 84
  • [10] FRANKEN PR, 1994, J NUCL MED, V35, P1758