Geometrical and Stress Analysis of Factors Associated With Stent Fracture After Melody Percutaneous Pulmonary Valve Implantation

被引:15
作者
Cosentino, Daria [1 ,2 ,3 ]
Quail, Michael A. [2 ,3 ]
Pennati, Giancarlo [4 ]
Capelli, Claudio [2 ,3 ]
Bonhoeffer, Philipp [5 ]
Diaz-Zuccarini, Vanessa [1 ]
Taylor, Andrew M. [2 ,3 ]
Schievano, Silvia [2 ,3 ]
机构
[1] UCL, Dept Mech Engn, London, England
[2] UCL, Inst Cardiovasc Sci, London, England
[3] UCL, Great Ormond St Hosp Children, London, England
[4] Politecn Milan, Dept Chem Engn, I-20133 Milan, Italy
[5] CNR Reg Toscana, Fdn G Monasterio, Pisa, Italy
基金
英国工程与自然科学研究理事会;
关键词
finite element analysis; pulmonary valve; stent; BARE METAL STENT; OUTFLOW TRACT; TRANSCATHETER; OUTCOMES; PLACEMENT; TRIAL;
D O I
10.1161/CIRCINTERVENTIONS.113.000631
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Patients treated with the Melody device (Medtronic) for percutaneous pulmonary valve implantation experience stent fractures in approximate to 25% of the cases. The aim of this study is to identify the risk factors associated with fracture using 3-dimensional (3D) analyses. Methods and Results-In situ 3D shape of the Melody stent was reconstructed from 42 patients using procedural biplane fluoroscopy images, after balloon inflation, at systole and diastole. Four geometric parameters at systole and their variation during balloon deflation and cardiac cycles were measured to describe the 3D strut, cell, section, and stent configuration. Furthermore, patient-specific computer simulations were set up to replicate the history of stent deformations for each patient. Maximum and minimum principal stresses resulting from these analyses were monitored during balloon deflation and cardiac cycle. Univariate logistic regression analyses of 21 geometric parameters and of 4 stress parameters respectively, identified the decreased stent circularity after balloon deflation (odds ratio 0.98; 95% confidence interval, 0.96-0.99; P=0.006) and large compressive stresses during balloon deflation (odds ratio, 0.98; 0.96-0.997; P=0.03), as associated with the risk of fracture. In a multivariable logistic regression model, the 2 covariates identified on univariate analysis (1 geometric and 1 stress) were found to be independently associated with the risk of fracture. The resultant statistical model correctly identified fracture/no fracture in 93% of patients. Conclusions-Changes in stent section shape after balloon deflation are important variables influencing fracture. This methodology could help design tailored follow-up for patients after percutaneous pulmonary valve implantation.
引用
收藏
页码:510 / 517
页数:8
相关论文
共 16 条
  • [1] Outcomes and safety of transcatheter pulmonary valve replacement in patients with large patched right ventricular outflow tracts
    Boudjemline, Younes
    Brugada, Georgia
    Van-Aerschot, Isabelle
    Patel, Mehul
    Basquin, Adeline
    Bonnet, Caroline
    Legendre, Antoine
    Bonnet, Damien
    Iserin, Laurence
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (8-9) : 404 - 413
  • [2] Melody transcatheter pulmonary valve implantation. Results from the registry of the Italian society of pediatric cardiology
    Butera, Gianfranco
    Milanesi, Ornella
    Spadoni, Isabella
    Piazza, Luciane
    Donti, Andrea
    Ricci, Christian
    Agnoletti, Gabriella
    Pangrazi, Alberta
    Chessa, Massimo
    Carminati, Mario
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (02) : 310 - 316
  • [3] Uncertainty assessment of imaging techniques for the 3D reconstruction of stent geometry
    Cosentino, Daria
    Zwierzak, Iwona
    Schievano, Silvia
    Diaz-Zuccarini, Vanessa
    Fenner, John W.
    Narracott, Andrew J.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (08) : 1062 - 1068
  • [4] Percutaneous Pulmonary Valve Implantation Preceded by Routine Prestenting With a Bare Metal Stent
    Demkow, Marcin
    Biernacka, Elzbieta Katarzyna
    Spiewak, Mateusz
    Kowalski, Miroslaw
    Siudalska, Hanna
    Wolski, Piotr
    Sondergaard, Lars
    Misko, Jolanta
    Hoffman, Piotr
    Ruzyllo, Witold
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (03) : 381 - 389
  • [5] Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients
    Eicken, Andreas
    Ewert, Peter
    Hager, Alfred
    Peters, Bjoern
    Fratz, Sohrab
    Kuehne, Titus
    Busch, Raymonde
    Hess, John
    Berger, Felix
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 (10) : 1260 - 1265
  • [6] Percutaneous pulmonary valve replacement
    Fleming, Gregory A.
    Hill, Kevin D.
    Green, Amanda S.
    Rhodes, John F.
    [J]. PROGRESS IN PEDIATRIC CARDIOLOGY, 2012, 33 (02) : 143 - 150
  • [7] Lurz Philipp, 2009, Expert Rev Cardiovasc Ther, V7, P823, DOI 10.1586/erc.09.57
  • [8] Stent Fracture, Valve Dysfunction, and Right Ventricular Outflow Tract Reintervention After Transcatheter Pulmonary Valve Implantation Patient-Related and Procedural Risk Factors in the US Melody Valve Trial
    McElhinney, Doff B.
    Cheatham, John P.
    Jones, Thomas K.
    Lock, James E.
    Vincent, Julie A.
    Zahn, Evan M.
    Hellenbrand, William E.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (06) : 602 - U130
  • [9] Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial
    McElhinney, Doff B.
    Hellenbrand, William E.
    Zahn, Evan M.
    Jones, Thomas K.
    Cheatham, John P.
    Lock, James E.
    Vincent, Julie A.
    [J]. CIRCULATION, 2010, 122 (05) : 507 - U132
  • [10] Percutaneous pulmonary valve-in-valve implantation: a successful treatment concept for early device failure
    Nordmeyer, Johannes
    Coats, Louise
    Lurz, Philipp
    Lee, Twin-Yen
    Derrick, Graham
    Rees, Philipp
    Cullen, Seamus
    Taylor, Andrew M.
    Khambadkone, Sachin
    Bonhoeffer, Philipp
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (06) : 810 - 815