Advanced single-slice rebinning in cone-beam spiral CT

被引:123
|
作者
Kachelriess, M [1 ]
Schaller, S
Kalender, WA
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[2] Siemens AG, Med Engn Grp, Forchheim, Germany
关键词
computed tomography (CT); spiral CT; multi-slice CT; cone-beam detector systems; 3D reconstruction;
D O I
10.1118/1.598938
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To achieve higher volume coverage at improved z-resolution in computed tomography (CT), systems with a large number of detector rows are demanded. However, handling an increased number of detector rows, as compared to today's four-slice scanners, requires to accounting for the cone geometry of the beams. Many so-called cone-beam reconstruction algorithms have been proposed during the last decade. None met all the requirements of the medical spiral cone-beam CT in regard to the need for high image quality, low patient dose and low reconstruction times. We therefore propose an approximate cone-beam algorithm which uses virtual reconstruction planes tilted to optimally fit 180 degrees spiral segments, i.e., the advanced single-slice rebinning (ASSR) algorithm. Our algorithm is a modification of the single-slice rebinning algorithm proposed by Noo et nl. [Phys. Med. Biol. 44, 561-570 (1999)] since we use tilted reconstruction slices instead of transaxial slices to approximate the spiral path. Theoretical considerations as well as the reconstruction of simulated phantom data in comparison to the gold standard 180 degrees LI (single-slice spiral CT) were carried out. Image artifacts, z-resolution as well as noise levels were evaluated for all simulated scanners. Even for a high number of detector rows the artifact level in the reconstructed images remains comparable to that of 180 degrees LI. Multiplanar reformations of the Defrise phantom show none of the typical cone-beam artifacts usually appearing when going to larger cone angles. Image noise as well as the shape of the respective slice sensitivity profiles are equivalent to the single-slice spiral reconstruction, z-resolution is slightly decreased. The ASSR has the potential to became a practical tool for medical spiral cone-beam CT. Its computational complexity lies in the order of standard single-slice CT and it allows to use available 2D backprojection hardware. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:754 / 772
页数:19
相关论文
共 50 条
  • [1] Advanced single-slice rebinning for tilted spiral cone-beam CT
    Kachelriess, M
    Fuchs, T
    Schaller, S
    Kalender, WA
    MEDICAL PHYSICS, 2001, 28 (06) : 1033 - 1041
  • [2] Advanced single-slice rebinning in cone-beam spiral CT: theoretical considerations and medical applications
    Kachelriess, M
    Schaller, S
    Kalender, WA
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 494 - 505
  • [3] Advanced Single-Slice Rebinning (ASSR) and misalignment correction for large cone-beam spiral CT
    Kachelriess, M
    Kalender, WA
    RADIOLOGY, 2000, 217 : 404 - 404
  • [4] Single-slice rebinning method for helical cone-beam CT
    Noo, F
    Defrise, M
    Clackdoyle, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02): : 561 - 570
  • [5] Single-slice rebinning reconstruction in spiral cone-beam computed tomography
    Bruder, H
    Kachelriess, M
    Schaller, S
    Stierstorfer, K
    Flohr, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 873 - 887
  • [6] Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    Kachelriess, M
    Watzke, O
    Kalender, WA
    MEDICAL PHYSICS, 2001, 28 (04) : 475 - 490
  • [7] Single-slice reconstruction method for helical cone-beam differential phase-contrast CT
    Fu, Jian
    Chen, Liyuan
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 45 - 51
  • [8] Rebinning-based algorithms for helical cone-beam CT
    Defrise, M
    Noo, F
    Kudo, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11): : 2911 - 2937
  • [9] Cone-beam spiral CT: First experimental results
    Karolczak, M
    Seibert, U
    Lutz, A
    Engelke, K
    Noo, F
    Kalender, WA
    RADIOLOGY, 2000, 217 : 404 - 404
  • [10] Single-slice rebinning reconstruction method for segmented helical computed tomography
    Wang, Zhisheng
    Cui, Junning
    Bian, Xingyuan
    Tang, Ran
    Li, Zongfeng
    Li, Sangyu
    Lin, Legeng
    Wang, Shunli
    OPTICS EXPRESS, 2023, 31 (19) : 30514 - 30528