A Novel Approach to Reduce Breast Radiation Exposure with Coronary CTA: Angled Axial Image Acquisition

被引:2
作者
Halpern, Ethan J. [1 ]
Takakuwa, Kevin M. [2 ]
Gingold, Eric L. [1 ]
Halpern, David J. [1 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ Hosp, Dept Emergency Med, Philadelphia, PA 19107 USA
关键词
Coronary CT angiography; computed tomography; radiation dose; breast radiation exposure; HELICAL MULTISLICE CT; COMPUTED-TOMOGRAPHY; FEMALE BREAST; BEAM CT; RECONSTRUCTION; ANGIOGRAPHY; QUALITY;
D O I
10.1016/j.acra.2009.02.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To determine whether angled gantry acquisition might be used to image the heart with a shorter scan length and reduced breast exposure during coronary computed tomography angiography. Materials and Methods. One hundred consecutive coronary computed tomography angiography examinations of female patients were retrospectively evaluated to define the angle between the long axis of the left heart and the axial imaging plane. The scan length required to image the entire left ventricle along with the coronary arteries was measured for an axial scan plane as well as for a scan plane parallel to the long axis of the left heart. The overlap between these imaging volumes and the lower portion of the breast was measured. Results. The long axis of the left heart varied from 7 degrees to 54 degrees off the axial plane (mean 32 degrees +/- 7 degrees). The required scan length to include the entire left ventricle and coronary arteries ranged from 8.2 to 12.4 cm (mean, 10.0 +/- 0.9 cm) for the axial scan plane and 5.6-10.1 cm (mean, 7.5 +/- 0.8 cm) for a scan plane parallel to the long axis of the heart (P < .001). cCTA in the axial plane required a 7.4 +/- 1.6 cm overlap with the lower breast, whereas cCTA in the long axis of the heart reduced the overlap to 4.5 +/- 1.8 cm (P < .001). Conclusions. Using an angled gantry approach, the coronary arteries can be fully imaged in a plane along the long axis of the left heart with a single 10-cm acquisition and with substantial reduction in amount of breast tissue within the irradiated field.
引用
收藏
页码:951 / 956
页数:6
相关论文
共 18 条
[1]  
Achenbach Stephan, 2007, J Cardiovasc Comput Tomogr, V1, P3, DOI 10.1016/j.jcct.2007.04.007
[2]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[3]  
EARLS JP, 2008, INT J CARDIOVAS 1125
[4]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[5]   Feldkamp-based cone-beam reconstruction for gantry-tilted helical multislice CT [J].
Hein, I ;
Taguchi, K ;
Silver, MD ;
Kazama, M ;
Mori, I .
MEDICAL PHYSICS, 2003, 30 (12) :3233-3242
[6]   Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: Assessment of image quality, stenosis, and radiation dose [J].
Hirai, Nobuhiko ;
Horiguchi, Jun ;
Fujioka, Chikako ;
Kiguchi, Masao ;
Yamamoto, Hideya ;
Matsuura, Noriaki ;
Kitagawa, Toshiro ;
Teragawa, Hiroki ;
Kohno, Nobuoki ;
Ito, Katsuhide .
RADIOLOGY, 2008, 248 (02) :424-430
[7]   Tomographic reconstruction for tilted helical multislice CT [J].
Hsieh, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) :864-872
[8]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152
[9]  
*INT COMM RAD PROT, 2004, ICRP PUBL, V92
[10]   Advanced single-slice rebinning for tilted spiral cone-beam CT [J].
Kachelriess, M ;
Fuchs, T ;
Schaller, S ;
Kalender, WA .
MEDICAL PHYSICS, 2001, 28 (06) :1033-1041