Analysis of Polarization-Depolarization Current, recorded from high voltage oil-paper insulation using insulation model is common among researchers. It is reported that paper insulation of power transformers undergoes non-uniform aging. Unlike Conventional Debye Model (CDM), Modified Debye Model (MDM) is capable of modeling such non-uniform aging. However, factors like insulation geometry affect the values of the MDM branch parameters. Therefore, model parameterized using data obtained from one insulation system finds limited use in assessing the condition of a different transformer, even with similar loading history and power rating. The present paper shows that a performance parameter, which is less sensitive to insulation geometry, can be evaluated from Transfer Function, TFM(s) of MDM. The parameter is the zero Z(1) of TFM(s) which is located farthest away from the origin in the Left Half Plane of s-plane. The capability of Z(1) as an insulation condition sensitive parameter is first tested on laboratory samples and then on data recorded from several real life power transformers. Results obtained for these transformers show that there is a good correlation between magnitude of Z(1) and paper moisture content obtained from Frequency Domain Spectroscopy (FDS) using IDAX 300.
引用
收藏
页码:2028 / 2036
页数:9
相关论文
共 50 条
  • [41] Condition Assessment of the Electrical Insulation in a High Voltage Current Transformer Using an Oil/Sand Mix
    Irelandes, Adam
    Saha, T. K.
    Jones, Colin
    IEEE ELECTRICAL INSULATION MAGAZINE, 2016, 32 (01) : 14 - 20
  • [42] Study on Quantitative Correlations between the Ageing Condition of Transformer Cellulose Insulation and the Large Time Constant Obtained from the Extended Debye Model
    Zhang, Yiyi
    Liu, Jiefeng
    Zheng, Hanbo
    Wei, Hua
    Liao, Ruijin
    ENERGIES, 2017, 10 (11):
  • [43] Condition assessment model for power transformer in service based on fuzzy synthetic evaluation
    Key Laboratory of Ministry of Education on High Voltage Engineering, Chongqing University, Chongqing 400044, China
    不详
    Dianli Xitong Zidonghue, 2008, 3 (70-75):
  • [44] Application of fuzzy set pair analysis model to power transformer condition assessment
    Yu, Qian
    Li, Weiguo
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2013, 44 (02): : 598 - 603
  • [45] Effect of Charge Accumulated at Oil-Paper Interface on Zero of Transfer Function Formulated Using Classical Debye Model Parameters
    Mishra, D.
    Pradhan, A. K.
    Baral, A.
    Haque, N.
    Chakravorti, S.
    2017 3RD INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2017, : 393 - 397
  • [46] Multi-fault Diagnosis Method for Insulation Condition of Power Transformer Based upon Cloud Model
    Wang, Jiyu
    Liao, Ruijin
    Zhang, Yiyi
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 564 - 567
  • [47] A Novel Method to Predict Moisture in Cellulosic Insulation of Power Transformer with Improved Accuracy Using Time Domain Spectroscopy Data
    Goel, R.
    Verma, H. C.
    Baral, A.
    Chakravorti, S.
    2017 6TH INTERNATIONAL CONFERENCE ON COMPUTER APPLICATIONS IN ELECTRICAL ENGINEERING - RECENT ADVANCES (CERA), 2017, : 205 - 208
  • [48] Aging Condition Assessment of Transformer Oil-paper Insulation Model based on Partial Discharge Analysis
    Liao, Rui-jin
    Yang, Li-jun
    Li, Jian
    Grzybowski, Stanislaw
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (01) : 303 - 311
  • [49] Insulation life assessment of power transformer thermal characteristics using Monte Carlo simulation
    Du, Lin
    Yuan, Lei
    Xiong, Hao
    Yang, Li-Jun
    Li, Jian
    Sun, Cai-Xin
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (04): : 856 - 861
  • [50] Expert system for the assessment of power transformer insulation condition based on type-2 fuzzy logic systems
    Flores, Wilfredo C.
    Mombello, Enrique E.
    Jardini, Jose A.
    Ratta, Giuseppe
    Corvo, Antonio M.
    EXPERT SYSTEMS WITH APPLICATIONS, 2011, 38 (07) : 8119 - 8127