Effect of thermocycling on the shear bond strength of a cyanoacrylate orthodontic adhesive

被引:51
作者
Bishara, SE [1 ]
Ajlouni, R [1 ]
Laffoon, JF [1 ]
机构
[1] Univ Iowa, Coll Dent, Dept Orthodont, Iowa City, IA 52242 USA
关键词
D O I
10.1067/mod.2003.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to evaluate the effects of thermocycling on the shear bond strength of a cyanoacrylate adhesive system, specifically 24 hours after bonding when the adhesive has achieved most of its bond strength and after thermocycling. Forty freshly extracted human molars were collected and stored in a solution of 0.1% (weight/volume) thymol. The teeth were cleaned, polished, and randomly separated into 2 groups: group 1, cyanoacrylate adhesive debonded after 24 hours immersion in deionized water at 37degreesC; and group 11, cyanoacrylate adhesive debonded after thermocycling at 5degreesC and 55degreesC. The results of the t test comparing the 2 groups (t = 6.84) indicated significant differences between them (P =.0001). The cyanoacrylate adhesive at 24 hours had significantly greater shear bond strength (R = 7.1 +/- 3.3 MPa) than after thermocycling 500 times between 5degreesC and 55degreesC (k = 1.5 +/- 1.4 MPa). The findings indicated that the cyanoacrylate adhesive tested has clinically adequate shear bond strength at 24 hours after initial bonding but loses about 80% of its strength after thermocycling. The clinician should consider all properties of the adhesive, including no need for a curing light, working time of 5 seconds before the adhesive starts to set, and the significant decrease in bond strength after thermocycling.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 23 条
[1]   SHEAR BOND STRENGTH OF CERAMIC ORTHODONTIC BRACKETS TO ENAMEL [J].
BRITTON, JC ;
MCINNES, P ;
WEINBERG, R ;
LEDOUX, WR ;
RETIEF, DH .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1990, 98 (04) :348-353
[2]  
Ferracane JL, 1998, J BIOMED MATER RES, V42, P465, DOI 10.1002/(SICI)1097-4636(19981205)42:3<465::AID-JBM17>3.0.CO
[3]  
2-F
[4]   Thermal cycling procedures for laboratory testing of dental restorations [J].
Gale, MS ;
Darvell, BW .
JOURNAL OF DENTISTRY, 1999, 27 (02) :89-99
[5]   BONDING METAL BRACKETS WITH A SELF-POLYMERIZING SEALANT-COMPOSITE - 12-MONTH ASSESSMENT [J].
GORELICK, L .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1977, 71 (05) :542-553
[6]  
JENKINS GN, 1963, PHYSL MOUTH, P422
[7]   CRANIOFACIAL MORPHOLOGY OCCLUSAL TRAITS, AND BITE FORCE IN PERSONS WITH ADVANCED OCCLUSAL TOOTH WEAR [J].
KILIARIDIS, S ;
JOHANSSON, A ;
HARALDSON, T ;
OMAR, R ;
CARLSSON, GE .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1995, 107 (03) :286-292
[8]  
Mizrahi E, 1969, Br Dent J, V127, P371
[9]  
MULHOLLAND RD, 1968, ANGLE ORTHOD, V38, P236
[10]   ADHESION AND ORTHODONTIC PLASTIC ATTACHMENTS [J].
NEWMAN, GV .
AMERICAN JOURNAL OF ORTHODONTICS, 1969, 56 (06) :573-&