Hemodynamic Monitoring in Sepsis

被引:24
作者
Casserly, Brian [2 ]
Read, Richard [1 ]
Levy, Mitchell M. [1 ]
机构
[1] Rhode Isl Hosp, Div Pulm & Crit Care Med, Providence, RI 02903 USA
[2] Brown Univ, Mem Hosp Rhode Isl, Div Pulm & Crit Care Med, Pawtucket, RI 02860 USA
关键词
Hemodynamic; Monitoring; Sepsis; Goal-directed; Intensive care; Physiologic; PULMONARY-ARTERY CATHETER; CRITICALLY-ILL PATIENTS; INTRATHORACIC BLOOD-VOLUME; RANDOMIZED CONTROLLED-TRIAL; GOAL-DIRECTED THERAPY; PREDICTS FLUID RESPONSIVENESS; CARDIAC-OUTPUT MEASUREMENT; EXTRAVASCULAR LUNG WATER; VENOUS OXYGEN-SATURATION; CARE NURSES KNOWLEDGE;
D O I
10.1016/j.ccc.2009.08.006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Tissue hypoperfusion is an important factor in the development of multiple organ failure. Therefore, recognition of sepsis-induced tissue hypoperfusion and timely clinical intervention to prevent and correct this are fundamental aspects of managing patients with sepsis and septic shock. Hemodynamic monitoring plays a key role in the management of the critically ill and is used to identify hemodynamic instability and its cause and to monitor response to therapy. However, the utility of many forms of hemodynamic monitoring that are used in management of sepsis and septic shock remain controversial and unproven. This article examines emerging technologies as well as more established techniques used to monitor hemodynamics in sepsis and assesses their potential roles in optimization of sepsis-induced tissue hypoperfusion.
引用
收藏
页码:803 / +
页数:22
相关论文
共 132 条
[1]  
Albrecht R, 2002, AM J SURG, V184, P559
[2]  
ASTIZ ME, 1986, CIRC SHOCK, V20, P281
[3]   RELATIONSHIP OF OXYGEN DELIVERY AND MIXED VENOUS OXYGENATION TO LACTIC-ACIDOSIS IN PATIENTS WITH SEPSIS AND ACUTE MYOCARDIAL-INFARCTION [J].
ASTIZ, ME ;
RACKOW, EC ;
KAUFMAN, B ;
FALK, JL ;
WEIL, MH .
CRITICAL CARE MEDICINE, 1988, 16 (07) :655-658
[4]   Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients [J].
Barbier, C ;
Loubières, Y ;
Schmit, C ;
Hayon, J ;
Ricôme, JL ;
Jardin, FO ;
Vieillard-Baron, A .
INTENSIVE CARE MEDICINE, 2004, 30 (09) :1740-1746
[5]   Significance of venous oximetry in the critically ill [J].
Bauer, P. ;
Reinhart, K. ;
Bauer, M. .
MEDICINA INTENSIVA, 2008, 32 (03) :134-142
[6]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[7]   Equipment review: New techniques for cardiac output measurement - oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis [J].
Berton, C ;
Cholley, B .
CRITICAL CARE, 2002, 6 (03) :216-221
[8]   Transoesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilution [J].
Bettex, DA ;
Hinselmann, V ;
Hellermann, JP ;
Jenni, R ;
Schmid, ER .
ANAESTHESIA, 2004, 59 (12) :1184-1192
[9]  
Bilkovski Robert N, 2004, Curr Opin Crit Care, V10, P529, DOI 10.1097/01.ccx.0000144771.96342.2c
[10]   HEMODYNAMIC AND OXYGEN-TRANSPORT PATTERNS IN SURVIVING AND NONSURVIVING POSTOPERATIVE-PATIENTS [J].
BLAND, RD ;
SHOEMAKER, WC ;
ABRAHAM, E ;
COBO, JC .
CRITICAL CARE MEDICINE, 1985, 13 (02) :85-90