Thermal response of wall implanted with heat pipes: Experimental analysis

被引:17
作者
Liu, Chang [1 ]
Zhang, Zhigang [1 ]
机构
[1] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
关键词
Wall implanted with heat pipes; Thermal response; Time lag; Decrement factor; Temperature rise coefficient; TIME-LAG; THERMOPHYSICAL PROPERTIES; DECREMENT FACTOR; BUILDING WALLS; TROMBE WALL; PERFORMANCE; TEMPERATURE;
D O I
10.1016/j.renene.2019.05.123
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A wall implanted with heat pipes (WIHP) features effective heat transfer between indoor and outdoor environments due to the pipe's unidirectional thermal conductivity: the implant also resolves the contradiction between the wall's insulation and solar energy utilization. The thermal performance of walls is crucial in terms of reducing a building's energy consumption and improving its indoor thermal environment. The heat transfer process of the condensing section is the focus of the present study. We establish a dynamic heat transfer model of the condensing section based on the Z-transfer function, and introduces the temperature rise coefficient (TRC) concept. The thermal response characteristics of an ordinary wall and WIHP are determined via theoretical analysis and experimentation. The WIHP shows a faster thermal response to weather variations than the ordinary wall. In a typical day, the efficient heat transfer and long running time (7 h 30 min) of the heat pipe improve the average inside-surface temperature of the WIHP by 0.5 degrees C and the average TRC by 0.16. A portion of the heat released from the pipe is also stored by the wall, which staves off temperature attenuation and minimizes temperature fluctuations in the inside surface, thereby creating a more comfortable indoor thermal environment. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1687 / 1697
页数:11
相关论文
共 26 条
[1]   Lightweight composite timber facade wall with improved thermal response [J].
Arkar, Ciril ;
Domjan, Suzana ;
Medved, Saso .
SUSTAINABLE CITIES AND SOCIETY, 2018, 38 :325-332
[2]   Effects of Wall's thermophysical properties on time lag and decrement factor [J].
Asan, H ;
Sancaktar, YS .
ENERGY AND BUILDINGS, 1998, 28 (02) :159-166
[3]   Analytical solution for the study of time lag and decrement factor for building walls in climate of Iran [J].
Fathipour, Reza ;
Hadidi, Amin .
ENERGY, 2017, 134 :167-180
[4]   TRANSIENT-RESPONSE OF THE TROMBE WALL TEMPERATURE DISTRIBUTION APPLICABLE TO PASSIVE SOLAR HEATING-SYSTEMS [J].
HSIEH, SS ;
TSAI, JT .
ENERGY CONVERSION AND MANAGEMENT, 1988, 28 (01) :21-25
[5]   A review on the application of Trombe wall system in buildings [J].
Hu, Zhongting ;
He, Wei ;
Ji, Jie ;
Zhang, Shengyao .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 70 :976-987
[6]   Passive thermal behaviour of buildings: Performance of external multi-layered walls and influence of internal walls [J].
Leccese, Francesco ;
Salvadori, Giacomo ;
Asdrubali, Francesco ;
Gori, Paola .
APPLIED ENERGY, 2018, 225 :1078-1089
[7]  
Mitalas G.P., 1978, ASHRAE Transformations, Vol, V84, P667
[8]   Some prospects of energy savings in buildings [J].
Mohsen, MS ;
Akash, BA .
ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (11) :1307-1315
[9]   TRANSWALL VERSUS TROMBE WALL - RELATIVE PERFORMANCE STUDIES [J].
NAYAK, JK .
ENERGY CONVERSION AND MANAGEMENT, 1987, 27 (04) :389-393
[10]   A new parameter for the dynamic analysis of building walls using the harmonic method [J].
Oliveti, G. ;
Arcuri, N. ;
Mazzeo, D. ;
De Simone, M. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 88 :96-109