Direct glucose sensing and biocompatible properties of a zinc oxide - multiwalled carbon nanotube-poly(vinyl chloride) ternary composite

被引:15
作者
Manikandan, Palinci Nagarajan [1 ]
Imran, Habibulla [1 ]
Dharuman, Venkataraman [1 ]
机构
[1] Alagappa Univ, Dept Bioelect & Biosensors, Mol Elect Lab, Karaikkudi 630003, Tamil Nadu, India
关键词
ELECTROCHEMICAL-BEHAVIOR; PASTE ELECTRODE; ZNO NANORODS; DOPED ZNO; NANOTUBES; SENSOR; NANOPARTICLES; BIOSENSOR; GRAPHENE; ARRAYS;
D O I
10.1039/c6ay00055j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Zinc oxide (ZnO), multi-walled carbon nanotubes (functionalized: fMWCNT and purified: pMWCNT), and poly(vinyl chloride) (PVC) (PVC-ZnO-MWCNT) are used for fabricating a ternary composite on a glassy carbon surface for direct glucose sensing. Enhanced glucose sensing is noticed with the PVC-ZnO-pMWCNT ternary composite in neutral (7.4) pH rather than in acid and alkaline pHs and not with the PVC-ZnO-fMWCNT and PVC-ZnO-MWCNT composites. The reasons for the highest activity of the PVC-ZnO-pMWCNT are examined using cyclic voltammetry (CV), chronoamperometry (CA), flow injection analysis (FIA), quartz crystal microbalance (QCM), Scanning Electron Microscopy (SEM), Fourier Infrared Spectroscopy (FTIR), X-ray diffraction (XRD), Raman spectroscopic and Transmission Electron Microscopic (TEM) techniques. The results suggest more interactions of ZnO with the pMWCNT rather than with the fMWCNT and MWCNT in the presence of PVC. Excellent selectivity of glucose in the presence of potential interferences, biocompatibility in the presence of blood proteins (bovine serum albumin and bilirubin) and antibacterial (Staphylococcus aureus and Keblisa pneumonia) activities are observed for ZnO in the presence of the MWCNT and PVC. The PVC-ZnO-pMWCNT composite shows the highest Michaelis-Menten kinetic constant k(M) of 21.9 mM compared to ZnO-glucose oxidase and copper oxide-ZnO systems which exhibit 10 times lower kM values. Blood glucose in different diabetic persons is discriminated very well without affecting the sensor performance.
引用
收藏
页码:2691 / 2697
页数:7
相关论文
共 49 条
[1]   Electrochemical behavior of morphine at ZnO/CNT nanocomposite room temperature ionic liquid modified carbon paste electrode and its determination in real samples [J].
Afsharmanesh, Elahe ;
Karimi-Maleh, Hassan ;
Pahlavan, Ali ;
Vahedi, Javad .
JOURNAL OF MOLECULAR LIQUIDS, 2013, 181 :8-13
[2]  
Aoun S.B., 2004, J ELECTROANAL CHEM, V567, P175, DOI DOI 10.1016/J.JELECHEM.2003.12.022
[3]  
Azdic R.R., 1986, J ELECTROANAL CHEM, V260, P475
[4]   SiO2 coated Fe3O4 magnetic nanoparticle dispersed multiwalled carbon nanotubes based amperometric glucose biosensor [J].
Baby, Tessy Theres ;
Ramaprabhu, S. .
TALANTA, 2010, 80 (05) :2016-2022
[5]   Nonenzymatic Glucose Sensor Based on Platinum Nanoflowers Decorated Multiwalled Carbon Nanotubes-Graphene Hybrid Electrode [J].
Badhulika, Sushmee ;
Paul, Rajat Kanti ;
Rajesh ;
Terse, Trupti ;
Mulchandani, Ashok .
ELECTROANALYSIS, 2014, 26 (01) :103-108
[6]   Ultraviolet-light-emitting ZnO nanosheets prepared by a chemical bath deposition method [J].
Cao, BQ ;
Cai, WP ;
Li, Y ;
Sun, FQ ;
Zhang, LD .
NANOTECHNOLOGY, 2005, 16 (09) :1734-1738
[7]   Nanosensors and nanomaterials for monitoring glucose in diabetes [J].
Cash, Kevin J. ;
Clark, Heather A. .
TRENDS IN MOLECULAR MEDICINE, 2010, 16 (12) :584-593
[8]   Electrochemical growth of nanopillar zinc oxide films by applying a low concentration of zinc nitrate precursor [J].
Chen, QP ;
Xue, MZ ;
Sheng, QR ;
Liu, YG ;
Ma, ZF .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2006, 9 (03) :C58-C61
[9]   Zinc Oxide/Reduced Graphene Oxide Composites and Electrochemical Capacitance Enhanced by Homogeneous Incorporation of Reduced Graphene Oxide Sheets in Zinc Oxide Matrix [J].
Chen, Yan-Li ;
Hu, Zhong-Ai ;
Chang, Yan-Qin ;
Wang, Huan-Wen ;
Zhang, Zi-Yu ;
Yang, Yu-Ying ;
Wu, Hong-Ying .
JOURNAL OF PHYSICAL CHEMISTRY C, 2011, 115 (05) :2563-2571
[10]  
Clark J. L. C., 1962, SCIENCE, V102, P29