Sizing of bubbles by incoherent imaging: Defocus bias

被引:35
作者
Bongiovanni, C [1 ]
Chevaillier, JP [1 ]
Fabre, J [1 ]
机构
[1] INST MECAN FLUIDES TOULOUSE,F-31400 TOULOUSE,FRANCE
关键词
D O I
10.1007/s003480050104
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Digitized images of millimeter bubbles are obtained with backlighting from a diffuse source. In order to investigate how the measured and real sizes of a bubble in or out of focus relate, a Ray Tracing Model of image formation, based on geometrical optics and photometric laws is developed. It emphasizes the contribution of direct, reflected and refracted rays. The model shows that the size of the source has a major role in the image formation. Moreover no reliable information on the defocus sign can be found in the image. A method for sizing blurred bubbles is suggested.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 14 条
[1]  
Born M., 1986, PRINCIPLES OPTICS
[2]  
CHARMAN WN, 1963, J ROYAL MICROSCOPICA, V82, P81
[3]   SCATTERING OF LIGHT BY AN AIR BUBBLE IN WATER [J].
DAVIS, GE .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1955, 45 (07) :572-581
[4]  
EPPINGER K, 1985, BUBBLE DISPERSION HO
[5]  
Goodman J. W., 2005, INTRO FOURIER OPTICS
[6]  
LEBRUN D, 1994, LINE PARTICLES SIZE
[7]   LINEWIDTH MEASUREMENT WITH AN OPTICAL MICROSCOPE - EFFECT OF OPERATING-CONDITIONS ON IMAGE PROFILE [J].
NYYSSONEN, D .
APPLIED OPTICS, 1977, 16 (08) :2223-2230
[8]   A NEW SENSE FOR DEPTH OF FIELD [J].
PENTLAND, AP .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (04) :523-531
[9]  
RISSO F, 1995, 12 EME C FRANC MEC
[10]   A STUDY OF ERRORS IN MEASUREMENT OF MICROSCOPIC SPHERES [J].
SAYLOR, CP .
APPLIED OPTICS, 1965, 4 (04) :477-&