Quantitative Determination of Spermidine in 50 German Cheese Samples on a Core-Shell Column by High-Performance Liquid Chromatography with a Photodiode Array Detector Using a Fully Validated Method

被引:17
|
作者
Esatbeyoglu, Tuba [1 ]
Ehmer, Andreas [1 ]
Chaize, Delphine [1 ]
Rimbach, Gerald [1 ]
机构
[1] Univ Kiel, Inst Human Nutr & Food Sci, Olshaussenstr 40, D-24118 Kiel, Germany
关键词
biogenic amines; cheese; HPLC-PDA; spermidine; validation; BIOGENIC-AMINES; POLYAMINES; AUTOPHAGY; FOODS;
D O I
10.1021/acs.jafc.6b00078
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
In the current study, the spermidine (8) contents of 51 German and 9 international cheese samples (from France, Ireland, Italy, The Netherlands, and Switzerland) were analyzed by a modified and fully validated method using high-performance liquid chromatography with photodiode array detection. After precolumn derivatization of biogenic amines with dansyl chloride (11), the compounds were separated on a Kinetex C18 column and detected at lambda = 254 nm. This method for compound 8 analysis in cheese was validated for the first time according to U.S. Food and Drug Administration (FDA) guidelines for bioanalytical method validation with regard to selectivity, precision, accuracy, recovery, linearity, lower limit of detection (LOD), lower limit of quantitation (LOQ), standard solution stability, short- and long-term stability, freeze thaw stability, and benchtop stability. The detector response was linear from 0.002 to 8 mg/L 8 (R-2 > 0.999). Low LOD and LOQ values of 1 and 2 mu g/L, respectively, reflected the high sensitivity of the method. The intra- and interday recoveries of the 8 spiked cheese samples ranged between 87.7 and 102.6%. This validated method was selective, accurate, and precise and was successfully applied for the quantitative analysis of compound 8 in 60 cheese samples. Furthermore, the simultaneous detection of eight additional biogenic amines is possible but not validated.
引用
收藏
页码:2105 / 2111
页数:7
相关论文
共 35 条
  • [1] A Fast and Validated Method for the Determination of Malondialdehyde in Fish Liver Using High-Performance Liquid Chromatography with a Photodiode Array Detector
    Faizan, Mohammad
    Esatbeyoglu, Tuba
    Bayram, Banu
    Rimbach, Gerald
    JOURNAL OF FOOD SCIENCE, 2014, 79 (04) : C484 - C488
  • [2] Emerging contaminant determination in water samples by liquid chromatography using a monolithic column coupled with a photodiode array detector
    Salvatierra-Stamp, Vilma del C.
    Ceballos-Magana, Silvia G.
    Gonzalez, Jorge
    Jurado, Jose M.
    Muniz-Valencia, Roberto
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (16) : 4661 - 4670
  • [3] Core shell column in high-performance liquid chromatography for the determination of polar compounds; troxerutin and carbazochrome
    Arslan, Merve Keskek
    Unal, Durisehvar Ozer
    ISTANBUL JOURNAL OF PHARMACY, 2020, 50 (01): : 16 - 20
  • [4] Rapid method for the quantification of 13 sulphonamides in milk by conventional high-performance liquid chromatography with diode array ultraviolet detection using a column packed with core-shell particles
    Armentano, Antonio
    Summa, Simona
    Lo Magro, Sonia
    Palermo, Carmen
    Nardiello, Donatella
    Centonze, Diego
    Muscarella, Marilena
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1531 : 46 - 52
  • [5] Development and Validation of a High-Performance Liquid Chromatography Method for the Determination of Histamine in Fish Samples Using Fluorescence Detection with Pre-column Derivatization
    Kounnoun, Ayoub
    El Maadoud, Mohamed
    Cacciola, Francesco
    Mondello, Luigi
    Bougtaib, Hajar
    Alahlah, Naoual
    Amajoud, Nadia
    El Baaboua, Aicha
    Louajri, Adnane
    CHROMATOGRAPHIA, 2020, 83 (07) : 893 - 901
  • [6] DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR
    Ijaz, Qazi Amir
    Abbas, Nasir
    Latif, Sumera
    Hussain, Amjad
    Arshad, Muhammad Sohail
    Ali, Ejaz
    Rashid, Memoona
    Sohail, Kashif
    Riaz, Sohail
    Bukhari, Nadeem Irfan
    ACTA POLONIAE PHARMACEUTICA, 2020, 77 (06): : 841 - 847
  • [7] Validated Bio-Analytical Method for Cinacalcet Concentrations in Rat Plasma by Reversed Phase-High Performance Liquid Chromatography- Photodiode Array Detector Method
    Rao, N. Mallikarjuna
    Mahammad, I. B.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 85 (01) : 83 - 92
  • [8] QUANTITATIVE SIMULTANEOUS DETERMINATION OF FENOFIBRATE, ATORVASTATIN, AND EZETIMIBE IN TABLETS USING GRADIENT HIGH-PERFORMANCE COLUMN LIQUID CHROMATOGRAPHY AND HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY
    Varghese, Susheel John
    Ravi, Thengungal Kochupappy
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (19) : 2784 - 2799
  • [9] Simultaneous Determination of the Five Marker Compounds in Melandrium firmum using High-Performance Liquid Chromatography with Photodiode-Array Detection
    Seo, Chang-Seob
    Shin, Hyeun-Kyoo
    NATURAL PRODUCT COMMUNICATIONS, 2016, 11 (11) : 1667 - 1669
  • [10] Development and Validation of a High-Performance Liquid Chromatography Method for the Determination of Histamine in Fish Samples Using Fluorescence Detection with Pre-column Derivatization
    Ayoub Kounnoun
    Mohamed EL Maadoudi
    Francesco Cacciola
    Luigi Mondello
    Hajar Bougtaib
    Naoual Alahlah
    Nadia Amajoud
    Aicha EL Baaboua
    Adnane Louajri
    Chromatographia, 2020, 83 : 893 - 901