The aim of the study was to see whether anew technique of a neck dissection applying an ultrasonic activated (harmonic) scalpel would improve patient recovery. Material and methods: A prospective, non-randomized study was undertaken on 40 supraomohyoid neck dissections performed using a harmonic scalpel (20 pts) or electrocoagulation (20 pts). The evaluation included: operation time, intraoperative blood loss, postoperative seroma formation and pattern of wound healing. Results: The operative time (mean +/- SD) using a harmonic scalpel was significantly shorter (52 +/- 10 min vs. 86 +/- 22 min; p <= 0.001) and the blood loss was less (13 +/- 7 ml vs. 85 +/- 58 ml; p <= 0.001), neck drainage on the first and second postoperative days were significantly smaller after using the ultrasonic scalpel (30 +/- 26 ml; 44 +/- 23 ml vs. 77 +/- 65 ml; 118 +/- 66 ml, p <= 0.001). Wound healing complications amounted to only 5% (20% in the control group). Conclusion: The use of the harmonic scalpel during neck dissection led to diminished bleeding, shorter operative time, lesser seroma formation and better wound healing in the postoperative period. (c) 2007 European Association for Cranio-Maxillofacial Surgery.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 19 条
  • [1] NON-SIMULTANEOUS BILATERAL RADICAL NECK DISSECTION
    BAFFI, R
    RAZACK, MS
    SAKO, K
    [J]. HEAD & NECK SURGERY, 1980, 2 (04): : 272 - 275
  • [2] Cabra Duenas J, 1994, Acta Otorrinolaringol Esp, V45, P447
  • [3] Crile G, 1906, J AMER MED ASSOC, V47, P1780
  • [4] Emam TA, 2003, ANN SURG, V237, P186
  • [5] Haegner U, 2002, HNO, V50, P836, DOI 10.1007/s00106-001-0607-3
  • [6] WOUND-HEALING OF SKIN INCISIONS PRODUCED BY ULTRASONICALLY VIBRATING KNIFE, SCALPEL, ELECTROSURGERY, AND CARBON-DIOXIDE LASER
    HAMBLEY, R
    HEBDA, PA
    ABELL, E
    COHEN, BA
    JEGASOTHY, BV
    [J]. JOURNAL OF DERMATOLOGIC SURGERY AND ONCOLOGY, 1988, 14 (11): : 1213 - 1217
  • [7] Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery
    Kinoshita, T
    Kanehira, E
    Omura, K
    Kawakami, K
    Watanabe, Y
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (06): : 621 - 625
  • [8] Ultrasonic energy in endoscopic surgery
    Lee, SJ
    Park, KH
    [J]. YONSEI MEDICAL JOURNAL, 1999, 40 (06) : 545 - 549
  • [9] Magrin J, 2000, J SURG ONCOL, V75, P232, DOI 10.1002/1096-9098(200012)75:4<232::AID-JSO2>3.3.CO
  • [10] 2-4