Comparison of haemocompatibility improvement of four polymeric biomaterials by two heparinization techniques

被引:55
作者
Michanetzis, GPA [1 ]
Katsala, N [1 ]
Missirlis, YF [1 ]
机构
[1] Univ Patras, Biomed Engn Lab, Dept Mech Engn & Aeronaut, GR-26500 Patras, Greece
关键词
heparinization; covalent binding; haemocompatibility; atomic force microscopy; scanning electron microscopy;
D O I
10.1016/S0142-9612(02)00382-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two surface heparinization procedures, introduced by Bamford and Al-Lamee (Polymer 22 (1996) 4885; 13 (1994) 2844) and Seifert et al. (J. Mater. Sci.: Mater. Med. 7 (1996) 465), respectively, were applied to four commercially available biomaterials (silicone rubber, polyethylene, polypropylene and polyvinylchloride) in order to compare their efficiency in improving haemocompatibility. The indirect method (Bamford and Al-Lamee) produced a much better heparinization yield-10.5%,, maximum, compared to the direct one (Seifert et al.), of only 0.20% maximum. Both methods provided a better response of the heparinized biomaterials compared to the uncoated ones in terms of platelet retention and a significantly better response in terms of activation of the coagulation system, suggesting that heparin molecules remained biologically functional in both cases. The results were particularly interesting in the case of polyvinylchloride where the maximum immobilization yield was obtained by the indirect method resulting also to a pronounced haeoocompatibility improvement. Scanning electron microscopy studies confirmed adhered platelet morphology whereas atonmic force microscopy was used to examine surface morphology of heparinized and reference materials surface. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:677 / 688
页数:12
相关论文
共 67 条
[1]  
[Anonymous], 1994, Hemostasis and thrombosis: basic principle and clinical practice
[2]   STUDIES IN POLYMER SURFACE FUNCTIONALIZATION AND GRAFTING FOR BIOMEDICAL AND OTHER APPLICATIONS [J].
BAMFORD, CH ;
ALLAMEE, KG .
POLYMER, 1994, 35 (13) :2844-2852
[3]   Studies in polymer surface modification and grafting for biomedical uses .2. Application to arterial blood filters and oxygenators [J].
Bamford, CH ;
AlLamee, KG .
POLYMER, 1996, 37 (22) :4885-4889
[4]   Cell activation and thrombin generation in heparin bonded cardiopulmonary bypass circuits using a novel in vitro model [J].
Bannan, S ;
Danby, A ;
Cowan, D ;
Ashraf, S ;
Gesinde, M ;
Martin, P .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 12 (02) :268-275
[5]   CONFORMATION OF HUMAN PLASMA-PROTEINS AT POLYMER SURFACES - THE EFFECTIVENESS OF SURFACE HEPARINIZATION [J].
BARBUCCI, R ;
MAGNANI, A .
BIOMATERIALS, 1994, 15 (12) :955-962
[6]   Which glycosaminoglycans are suitable for antithrombogenic or athrombogenic coatings of biomaterials? Part II: Covalently immobilized endothelial cell surface heparan sulfate (ESHS) and heparin (HE) on synthetic polymers and results of animal experiments [J].
Baumann, H ;
Keller, R .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 1997, 23 (02) :215-223
[7]   Biocompatibility reflected by haemostasis variables during cardiopulmonary bypass using heparin-coated circuits [J].
Borowiec, J ;
Bagge, L ;
Saldeen, T ;
Thelin, S .
THORACIC AND CARDIOVASCULAR SURGEON, 1997, 45 (04) :163-167
[8]   Pulsatile local delivery of thrombolytic and antithrombotic agents using poly(N-isopropylacrylamide-co-methacrylic acid) hydrogels [J].
Brazel, CS ;
Peppas, NA .
JOURNAL OF CONTROLLED RELEASE, 1996, 39 (01) :57-64
[9]  
Brynda E, 2000, J BIOMED MATER RES, V51, P249, DOI 10.1002/(SICI)1097-4636(200008)51:2<249::AID-JBM14>3.0.CO
[10]  
2-X