Visual Acuity Outcomes of the Boston Keratoprosthesis Type 1: Multicenter Study Results

被引:35
作者
Rudnisky, Christopher J. [1 ]
Belin, Michael W. [2 ]
Guo, Rong [3 ]
Ciolino, Joseph B. [3 ]
机构
[1] Univ Alberta, Dept Ophthalmol, Edmonton, AB, Canada
[2] Univ Arizona, Dept Ophthalmol & Vis Sci, Tucson, AZ USA
[3] Harvard Univ, Massachusetts Eye & Ear Infirm, Sch Med, Dept Ophthalmol, Boston, MA USA
基金
美国国家卫生研究院;
关键词
COUNTING FINGERS; HAND MOTION; GLAUCOMA; ENDOPHTHALMITIS; COMPLICATIONS; CATEGORIES; VISION;
D O I
10.1016/j.ajo.2015.10.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To report logarithm of the minimal angle of resolution (logMAR) visual outcomes of the Boston keratoprosthesis type 1. DESIGN: Prospective cohort study. METHODS: Preoperative, intraoperative, and postoperative parameters of 300 eyes of 300 patients who underwent implantation of a Boston keratoprosthesis type 1 device between January 2003 and July 2008 by 1 of 19 surgeons at 18 medical centers were collected. RESULTS: After an average of 17.1 +/- 14.8 months, visual acuity improved significantly (P < .0001) to a mean final value of 0.89 +/- 0.64 (20/150). There were also significantly fewer eyes with light perception (6.7%; n = 19; P < .0001), although 3.1% (n = 9) progressed to no light perception. There was no association between age (P = .08), sex (P = .959), operative side (P = .167), or failure (P = .494) and final visual acuity. The median time to achieve 20/200 visual acuity was 1 month (95% confidence interval 1.0-6.0) and it was retained for an average of 47.8 months. Multivariate analysis, controlling for preoperative visual acuity, demonstrated 2 factors associated with final visual outcome: chemical injury was associated with better final vision (P = .007), whereas age-related macular degeneration was associated with poorer vision (P < .0001). CONCLUSIONS: The Boston keratoprosthesis type 1 is an effective device for rehabilitation in advanced ocular surface disease, resulting in a significant improvement in visual acuity. Eyes achieved a mean value of 20/150 (0.89 0.64 IogMAR units) after 6 months and this was relatively stable thereafter. The best visual prognosis is observed in chemical injury eyes, whereas the worst prognosis is in aniridia, although the latter has limited visual potential. (C) 2016 by Elsevier Inc. All rights reserved.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 25 条
[1]  
Baker A, 1889, AM J OPHTHAL 2, V6, P1
[2]   Evaluation and management of glaucoma after keratoprosthesis [J].
Banitt, Michael .
CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (02) :133-136
[3]   Boston Keratoprosthesis Outcomes and Complications [J].
Chew, Hall F. ;
Ayres, Brandon D. ;
Hammersmith, Kristin M. ;
Rapuano, Christopher J. ;
Laibson, Peter R. ;
Myers, Jonathan S. ;
Jin, Ya-Ping ;
Cohen, Elisabeth J. .
CORNEA, 2009, 28 (09) :989-996
[4]   Retention of the Boston Keratoprosthesis Type 1: Multicenter Study Results [J].
Ciolino, Joseph B. ;
Belin, Michael W. ;
Todani, Amit ;
Al-Arfaj, Khalid ;
Rudnisky, Christopher J. .
OPHTHALMOLOGY, 2013, 120 (06) :1195-1200
[5]  
Dimmer F, 1889, BER OPHTHAL GES HEID, V20, P147
[6]   Short-Term Visual Outcomes of Boston Type 1 Keratoprosthesis Implantation [J].
Dunlap, Karen ;
Chak, Garrick ;
Aquavella, James V. ;
Myrowitz, Elliott ;
Utine, Canan Asli ;
Akpek, Esen .
OPHTHALMOLOGY, 2010, 117 (04) :687-692
[7]   Successful Prevention of Bacterial Endophthalmitis in Eyes with the Boston Keratoprosthesis [J].
Durand, Marlene L. ;
Dohlman, Claes H. .
CORNEA, 2009, 28 (08) :896-901
[8]   Characteristics of Endophthalmitis in Patients With the Boston Keratoprosthesis [J].
Fintelmann, Robert E. ;
Maguire, Joseph I. ;
Ho, Allen C. ;
Chew, Hall F. ;
Ayres, Brandon D. .
CORNEA, 2009, 28 (08) :877-878
[9]   Longer-Term Vision Outcomes and Complications with the Boston Type 1 Keratoprosthesis at the University of California, Davis [J].
Greiner, Mark A. ;
Li, Jennifer Y. ;
Mannis, Mark J. .
OPHTHALMOLOGY, 2011, 118 (08) :1543-1550
[10]  
HALL WJ, 1980, BIOMETRIKA, V67, P133