Wireless Power and Data Transmission with ASK Demodulator and Power Regulator for a Biomedical Implantable SOC

被引:15
作者
Kao, Chen-Hua [1 ]
Tang, Kea-Tiong [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
来源
2009 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP | 2009年
关键词
DEFIBRILLATOR; STIMULATION;
D O I
10.1109/LISSA.2009.4906740
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bio-medical implantable devices have appeared for more than fifty years. With more understandings of neuroscience, some diseases caused by neural abnormal discharge or disable may be cured or improved by neural stimulation techniques. Most of the wireless implantable devices transmit power and data into the no-battery implantable device by magnetic coupling. This paper presents an efficient power and data transmission, including LDO power regulator and ASK demodulator for biomedical implantable devices. The modulation index and rate are relative to power transmission efficiency. Results show that with a 2MHz carrier, the proposed ASK demodulator structure has a maximum modulation index up to 2.86% and a 50% maximum modulation rate. The modulation index is also tunable for different applications. The power regulator provides a stable 1.8V for the ASK demodulation. This design uses TSMC 0.18um 1P6M CMOS technology.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 22 条
[1]  
Berruecos P, 2000, AUDIOLOGY, V39, P221
[2]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[3]   Visual prosthetic device for bilateral end-stage macular degeneration [J].
Chun, Dal W. ;
Heier, Jeffrey S. ;
Raizman, Michael B. .
EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (06) :657-665
[4]  
DJEMOUAI A, 2003, 46 IEEE MIDW S CIRC
[5]   Reconstruction of Hyman's second pacemaker [J].
Furman, S ;
Szarka, G ;
Layvand, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (05) :446-453
[6]   A Truly Low-Cost High-Efficiency ASK Demodulator Based on Self-Sampling Scheme for Bioimplantable Applications [J].
Gong, Cihun-Siyong Alex ;
Shiue, Muh-Tian ;
Yao, Kai-Wen ;
Chen, Tong-Yi ;
Chang, Yin ;
Su, Chun-Hsien .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2008, 55 (06) :1464-1477
[7]  
Gudnason GA, 2000, IEEE INT SOL STAT CI, P385
[8]  
HMIDA GB, 2006, 2006 INT C DES TEST, P374
[9]  
ITOVSKY RY, 2006, EAR HEARING, V27, P43
[10]   The implantable miniature telescope for macular degeneration [J].
Lane, SS ;
Kuppermann, BD .
CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (01) :94-98