Using gold nanoparticles to improve the recovery and the limits of detection for the analysis of monohydroxy-polycyclic aromatic hydrocarbons in urine samples

被引:29
作者
Wang, Huiyong [1 ]
Wilson, Walter B. [1 ]
Campiglia, Andres D. [1 ]
机构
[1] Univ Cent Florida, Dept Chem, Orlando, FL 32816 USA
关键词
Monohydroxy-polycyclic aromatic hydrocarbons; Gold nanoparticles; SPE-HPLC; Urine; Fluorescence; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE MICROEXTRACTION; DRINKING-WATER SAMPLES; FLUORESCENCE DETECTION; MASS-SPECTROMETRY; METABOLITES; EXTRACTION; EXPOSURE; 1-HYDROXYPYRENE; QUANTIFICATION;
D O I
10.1016/j.chroma.2009.06.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a novel approach to improve the analytical figures of merit of solid-phase extraction high-performance liquid chromatography (SPE-HPLC) for the analysis of monohydroxy-polycyclic aromatic hydrocarbons in urine samples. The novel alternative substitutes the evaporation step that is currently used in SPE-HPLC methodology with a pre-concentration procedure that extracts metabolites with gold nanoparticles. The analytical potential of the new approach is evaluated with the following six metabolites: 9-hydroxyphenanthrene, 2-hydroxyfluorene, 1-hydroxypyrene, 6-hydroxychrysene, 3-hydroxybenzo[a]pyrene and 4-hydroxybenzo[a]pyrene. We demonstrate that the substitution of the evaporation step with the gold nanoparticles procedure improves the overall recoveries, the relative standard deviations of the average recoveries and the limits of detection of SPE-HPLC analysis. The overall recoveries of the studied metabolites varied from 59.7 +/- 3.6% (2-hydroxyfluorene) to 92.3 +/- 2.5% (6-hydroxychrysene). The relative standard deviations of the average recoveries were lower than 6%. The limits of detection were at the parts-per-trillion levels and varied from similar to 2 pg mL(-1) (6-hydroxychrysene) to similar to 18 pg mL(-1) (2-hydroxyfluorene). Published by Elsevier B.V.
引用
收藏
页码:5793 / 5799
页数:7
相关论文
共 18 条
[1]   Solid-liquid extraction laser excited time resolved Shpol'skii spectrometry: A facile method for the direct detection of 15 priority pollutants in water samples [J].
Bystol, AJ ;
Whitcomb, JL ;
Campiglia, AD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (12) :2566-2571
[2]   Fast screening method for the profile analysis of polycyclic aromatic hydrocarbon metabolites in urine using derivatisation - solid-phase microextraction [J].
Gmeiner, G ;
Krassnig, C ;
Schmid, E ;
Tausch, H .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 705 (01) :132-138
[3]   URINARY AND FECAL EXCRETION OF CHRYSENE AND CHRYSENE METABOLITES BY RATS AFTER ORAL, INTRAPERITONEAL, INTRATRACHEAL OR INTRAPULMONARY APPLICATION [J].
GRIMMER, G ;
BRUNE, H ;
DETTBARN, G ;
HEINRICH, U ;
JACOB, J ;
MOHTASHAMIPUR, E ;
NORPOTH, K ;
POTT, F ;
WENZELHARTUNG, R .
ARCHIVES OF TOXICOLOGY, 1988, 62 (06) :401-405
[4]   High-performance liquid chromatographic method with fluorescence detection for the determination of 3-hydroxybenzo[a]pyrene and 3-hydroxybenz[a]anthracene in the urine of polycyclic aromatic hydrocarbon-exposed workers [J].
Gündel, J ;
Angerer, J .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (01) :47-55
[5]   1-HYDROXYPYRENE IN HUMAN-URINE AFTER EXPOSURE TO COAL-TAR AND A COAL-TAR DERIVED PRODUCT [J].
JONGENEELEN, FJ ;
ANZION, RBM ;
LEIJDEKKERS, CM ;
BOS, RP ;
HENDERSON, PT .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1985, 57 (01) :47-55
[6]   Determination of 1-hydroxypyrene in children urine using column-switching liquid chromatography and fluorescence detection [J].
Kuo, CT ;
Chen, HW ;
Chen, JL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02) :187-193
[7]   Urinary hydroxy-metabolites of naphthalene, phenanthrene and pyrene as markers of exposure to diesel exhaust [J].
Kuusimäki, L ;
Peltonen, Y ;
Mutanen, P ;
Peltonen, K ;
Savela, K .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2004, 77 (01) :23-30
[8]  
Miller Miller J, 2000, STAT CHEMOMETRICS AN, Vfourth
[9]   Automated solid-phase extraction method for measuring urinary polycyclic aromatic hydrocarbon metabolites in human biomonitoring using isotope-dilution gas chromatography high-resolution mass spectrometry [J].
Romanoff, LC ;
Li, Z ;
Young, KJ ;
Blakely, NC ;
Patterson, DG ;
Sandau, CD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 835 (1-2) :47-54
[10]   Urinary biomarkers of exposure to jet fuel (JP-8) [J].
Serdar, B ;
Egeghy, PP ;
Waidyanatha, S ;
Gibson, R ;
Rappaport, SM .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2003, 111 (14) :1760-1764