Purpose: To study the relationship between retinal nerve fiber layer (RNFL) thickness measured by time domain (Stratus) and spectral domain (Cirrus HD) optical coherence tomography (OCT). Design: Cross-sectional study. Participants: Sixty healthy participants, 48 glaucoma suspects, and 55 subjects with glaucoma. Methods: Participants were imaged by a single trained operator using the Stratus OCT (fast RNFL scan mode) and Cirrus HD-OCT (optic disc cube mode) at the same visit. Main Outcome Measures: The RNFL thickness as measured by the Stratus OCT (fast RNFL scan mode) and Cirrus HD-OCT (optic disc cube mode) was compared (paired t test). The relationship between RNFL thickness measurements of the 2 OCTs were evaluated using a Pearson correlation analysis. The presence of abnormal classification, as determined by using an internal normative data base in each machine was compared (chi-square test). The sensitivity and specificity of normative classification of 2 OCT measurements were calculated. Results: Average RNFL thickness as determined by the 2 OCT machines was correlated (r = 0.94; P<0.001), but was significantly different with the 2 machines (Stratus, 98.0 mu m, standard deviation [SD] 18.0; Cirrus, 85.6 mu m, SD 14.6; P<0.001). The Cirrus HD-OCT classified a significantly higher percentage of eyes as abnormal (Stratus, 12.9%; Cirrus, 23.3%; P<0.001) in average RNFL thickness. Cirrus OCT demonstrated higher sensitivity and specificity (63.6% and 100%) than Stratus OCT (40.0% and 96.7%) in normative classification of average RNFL thickness. Conclusions: There were significant differences in RNFL thickness and normative classification as determined by Stratus OCT and Cirrus HD-OCT despite an excellent correlation of RNFL thickness measurement. Overall sensitivity and specificity were higher with Cirrus OCT. These findings are particularly relevant when an individual undergoes longitudinal follow-up with different OCTs. Financial Disclosure(s): The authors have no commercial or proprietary interest in any of the materials discussed in this article. Ophthalmology 2009,116:1264-1270 (C) 2009 by the American Academy of Ophthalmology.
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 25 条
  • [11] Baseline optical coherence tomography predicts the development of glaucomatous change in glaucoma suspects
    Lalezary, Maziar
    Medeiros, Felipe A.
    Weinreb, Robert N.
    Bowd, Christopher
    Sample, Pamela A.
    Tavares, Ivan M.
    Tafreshi, Ali
    Zangwill, Linda M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (04) : 576 - 582
  • [12] Comparison of macular and peripapillary measurements for the detection of glaucoma - An optical coherence tomography study
    Leung, CKS
    Chan, WM
    Yung, WH
    Ng, ACK
    Woo, J
    Tsang, MK
    Tse, RKK
    [J]. OPHTHALMOLOGY, 2005, 112 (03) : 391 - 400
  • [13] Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma
    Manassakorn, A
    Nouri-Mahdavi, K
    Caprioli, J
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) : 105 - 115
  • [14] Mayoral F., 2006, Arch Soc Esp Oftalmol, V81, P537
  • [15] Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography
    Medeiros, FA
    Zangwill, LM
    Bowd, C
    Vessani, RM
    Susanna, R
    Weinreb, RN
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) : 44 - 55
  • [16] Evaluation of optical coherence tomography and Heidelberg retinal tomography parameters in detecting early and moderate glaucoma
    Naithani, Prashant
    Sihota, Ramanjit
    Sony, Parul
    Dada, Tanuj
    Gupta, Viney
    Kondal, Dimple
    Pandey, Ravindra M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) : 3138 - 3145
  • [17] Detection of early glaucoma with optical coherence tomography (StratusOCT)
    Nouri-Mahdavi, Kouros
    Nikkhou, Kiavash
    Hoffman, Douglas C.
    Law, Simon K.
    Caprioli, Joseph
    [J]. JOURNAL OF GLAUCOMA, 2008, 17 (03) : 183 - 188
  • [18] Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma
    Parikh, Raiul S.
    Parikh, Shefali
    Sekhar, G. Chandra
    Kumar, Rajesh S.
    Prabakaran, S.
    Babu, J. Ganesh
    Thomas, Ravi
    [J]. OPHTHALMOLOGY, 2007, 114 (12) : 2238 - 2243
  • [19] Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT
    Paunescu, LA
    Schuman, JS
    Price, LL
    Stark, PC
    Beaton, S
    Ishikawa, H
    Wollstein, G
    Fujimoto, JG
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (06) : 1716 - 1724
  • [20] Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry
    Poinoosawmy, D
    Fontana, L
    Wu, JX
    Fitzke, FW
    Hitchings, RA
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (05) : 350 - 354