Comparison of Retinal Nerve Fiber Layer Thickness Measured by Cirrus HD and Stratus Optical Coherence Tomography

被引:174
作者
Sung, Kyung Rim [1 ]
Kim, Dong Yoon [1 ]
Park, Sung Bae [1 ]
Kook, Michael S. [1 ]
机构
[1] Univ Ulsan, Coll Med, Dept Ophthalmol, Asan Med Ctr, Seoul 138736, South Korea
关键词
SCANNING LASER POLARIMETRY; EARLY GLAUCOMA; OCULAR HYPERTENSION; MACULAR THICKNESS; EYES; REPRODUCIBILITY; DISK; OCT; CLASSIFIERS; PROGRESSION;
D O I
10.1016/j.ophtha.2008.12.045
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the relationship between retinal nerve fiber layer (RNFL) thickness measured by time domain (Stratus) and spectral domain (Cirrus HD) optical coherence tomography (OCT). Design: Cross-sectional study. Participants: Sixty healthy participants, 48 glaucoma suspects, and 55 subjects with glaucoma. Methods: Participants were imaged by a single trained operator using the Stratus OCT (fast RNFL scan mode) and Cirrus HD-OCT (optic disc cube mode) at the same visit. Main Outcome Measures: The RNFL thickness as measured by the Stratus OCT (fast RNFL scan mode) and Cirrus HD-OCT (optic disc cube mode) was compared (paired t test). The relationship between RNFL thickness measurements of the 2 OCTs were evaluated using a Pearson correlation analysis. The presence of abnormal classification, as determined by using an internal normative data base in each machine was compared (chi-square test). The sensitivity and specificity of normative classification of 2 OCT measurements were calculated. Results: Average RNFL thickness as determined by the 2 OCT machines was correlated (r = 0.94; P<0.001), but was significantly different with the 2 machines (Stratus, 98.0 mu m, standard deviation [SD] 18.0; Cirrus, 85.6 mu m, SD 14.6; P<0.001). The Cirrus HD-OCT classified a significantly higher percentage of eyes as abnormal (Stratus, 12.9%; Cirrus, 23.3%; P<0.001) in average RNFL thickness. Cirrus OCT demonstrated higher sensitivity and specificity (63.6% and 100%) than Stratus OCT (40.0% and 96.7%) in normative classification of average RNFL thickness. Conclusions: There were significant differences in RNFL thickness and normative classification as determined by Stratus OCT and Cirrus HD-OCT despite an excellent correlation of RNFL thickness measurement. Overall sensitivity and specificity were higher with Cirrus OCT. These findings are particularly relevant when an individual undergoes longitudinal follow-up with different OCTs. Financial Disclosure(s): The authors have no commercial or proprietary interest in any of the materials discussed in this article. Ophthalmology 2009,116:1264-1270 (C) 2009 by the American Academy of Ophthalmology.
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 25 条
[11]   Baseline optical coherence tomography predicts the development of glaucomatous change in glaucoma suspects [J].
Lalezary, Maziar ;
Medeiros, Felipe A. ;
Weinreb, Robert N. ;
Bowd, Christopher ;
Sample, Pamela A. ;
Tavares, Ivan M. ;
Tafreshi, Ali ;
Zangwill, Linda M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (04) :576-582
[12]   Comparison of macular and peripapillary measurements for the detection of glaucoma - An optical coherence tomography study [J].
Leung, CKS ;
Chan, WM ;
Yung, WH ;
Ng, ACK ;
Woo, J ;
Tsang, MK ;
Tse, RKK .
OPHTHALMOLOGY, 2005, 112 (03) :391-400
[13]   Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma [J].
Manassakorn, A ;
Nouri-Mahdavi, K ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) :105-115
[14]  
Mayoral F., 2006, Arch Soc Esp Oftalmol, V81, P537
[15]   Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Vessani, RM ;
Susanna, R ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) :44-55
[16]   Evaluation of optical coherence tomography and Heidelberg retinal tomography parameters in detecting early and moderate glaucoma [J].
Naithani, Prashant ;
Sihota, Ramanjit ;
Sony, Parul ;
Dada, Tanuj ;
Gupta, Viney ;
Kondal, Dimple ;
Pandey, Ravindra M. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3138-3145
[17]   Detection of early glaucoma with optical coherence tomography (StratusOCT) [J].
Nouri-Mahdavi, Kouros ;
Nikkhou, Kiavash ;
Hoffman, Douglas C. ;
Law, Simon K. ;
Caprioli, Joseph .
JOURNAL OF GLAUCOMA, 2008, 17 (03) :183-188
[18]   Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma [J].
Parikh, Raiul S. ;
Parikh, Shefali ;
Sekhar, G. Chandra ;
Kumar, Rajesh S. ;
Prabakaran, S. ;
Babu, J. Ganesh ;
Thomas, Ravi .
OPHTHALMOLOGY, 2007, 114 (12) :2238-2243
[19]   Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT [J].
Paunescu, LA ;
Schuman, JS ;
Price, LL ;
Stark, PC ;
Beaton, S ;
Ishikawa, H ;
Wollstein, G ;
Fujimoto, JG .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (06) :1716-1724
[20]   Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry [J].
Poinoosawmy, D ;
Fontana, L ;
Wu, JX ;
Fitzke, FW ;
Hitchings, RA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (05) :350-354