Real-time kinetic binding studies at attomolar concentrations in solution phase using a single-stage opto-biosensing platform based upon infrared surface plasmons

被引:11
作者
Allsop, T. [1 ]
Mou, C. [2 ]
Neal, R. [3 ]
Mariani, S. [4 ,5 ]
Nagel, D. [6 ]
Tombelli, S. [7 ]
Poole, A. [6 ]
Kalli, K. [8 ]
Hine, A. [6 ]
Webb, D. J. [1 ]
Culverhouse, P. [3 ]
Mascini, M. [4 ,5 ]
Minunni, M. [4 ,5 ]
Bennion, I. [1 ]
机构
[1] Aston Univ, Aston Inst Photon Technol, Birmingham B4 7ET, W Midlands, England
[2] Shanghai Univ, Key Lab Special Fiber Opt & Opt Access Network, Shanghai 200072, Peoples R China
[3] Univ Plymouth, Fac Sci & Technol, Dept Maths & Comp, Plymouth PL4 8AA, Devon, England
[4] Univ Florence, Dipartimento Chim Ugo Schiff, Via Lastruccia 3, I-50019 Sesto Fiorentino, Italy
[5] Univ Florence, CSGI, Via Lastruccia 3, I-50019 Sesto Fiorentino, Italy
[6] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
[7] CNR, Ist Fis Applicata Nello Carrara, Via Madonna Piano 10, I-50126 Sesto Fiorentino, Italy
[8] Cyprus Univ Technol, Dept Elect Engn Comp Engn & Informat, Nanophoton Res Lab, 31 Archbishop Kyprianos, CY-3036 Lemessos, Cyprus
基金
英国工程与自然科学研究理事会;
关键词
THROMBIN GENERATION; RESONANCE BIOSENSORS; SENSORS; APTAMERS; FIBER; ASSAY; TRANSMISSION; MOLECULES; AFFINITY; LIGANDS;
D O I
10.1364/OE.25.000039
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Here we present a new generic opto-bio-sensing platform combining immobilised aptamers on an infrared plasmonic sensing device generated by nano-structured thin film that demonstrates amongst the highest index spectral sensitivities of any optical fibre sensor yielding on average 3.4 x 10(4) nm/RIU in the aqueous index regime (with a figure of merit of 330) This offers a single stage, solution phase, atto-molar detection capability, whilst delivering real-time data for kinetic studies in water-based chemistry. The sensing platform is based upon optical fibre and has the potential to be multiplexed and used in remote sensing applications. As an example of the highly versatile capabilities of aptamer based detection using our platform, purified thrombin is detected down to 50 attomolar concentration using a volume of 1mm3 of solution without the use of any form of enhancement technique. Moreover, the device can detect nanomolar levels of thrombin in a flow cell, in the presence of 4.5% w/v albumin solution. These results are important, covering all concentrations in the human thrombin generation curve, including the problematic initial phase. Finally, selectivity is confirmed using complementary and non-complementary DNA sequences that yield performances similar to those obtained with thrombin. (C) 2016 Optical Society of America
引用
收藏
页码:39 / 58
页数:20
相关论文
共 53 条
[1]   A simple and accurate mathematical method for calculation of the EC50 [J].
Alexander, B ;
Browse, DJ ;
Reading, SJ ;
Benjamin, IS .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1999, 41 (2-3) :55-58
[2]   Exploitation of multilayer coatings for infrared surface plasmon resonance fiber sensors [J].
Allsop, T. ;
Neal, R. ;
Mou, C. ;
Brown, P. ;
Saied, S. ;
Rehman, S. ;
Kalli, K. ;
Webb, D. J. ;
Sullivan, J. ;
Mapps, D. ;
Bennion, I. .
APPLIED OPTICS, 2009, 48 (02) :276-286
[3]  
Allsop T, 2006, OFS 18 CANCUN MEXICO, pWA4
[4]   Formation and Characterization of Ultra-Sensitive Surface Plasmon Resonance Sensor Based Upon a Nano-Scale Corrugated Multi-Layered Coated D-Shaped Optical Fiber [J].
Allsop, Thomas D. P. ;
Neal, Ronald ;
Mou, Chengbo ;
Kalli, Kyriacos ;
Saied, Sayah ;
Rehman, Saeed ;
Webb, David J. ;
Culverhouse, P. F. ;
Sullivan, John L. ;
Bennion, Ian .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 2012, 48 (03) :394-405
[5]   ANALYSIS OF RECEPTOR-LIGAND INTERACTIONS [J].
ATTIE, AD ;
RAINES, RT .
JOURNAL OF CHEMICAL EDUCATION, 1995, 72 (02) :119-124
[6]   Quantification of cytokines involved in wound healing using surface plasmon resonance [J].
Battaglia, TM ;
Masson, JF ;
Sierks, MR ;
Beaudoin, SP ;
Rogers, J ;
Foster, KN ;
Holloway, GA ;
Booksh, KS .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :7016-7023
[7]   Surface plasmon resonance imaging measurements of ultrathin organic films [J].
Brockman, JM ;
Nelson, BP ;
Corn, RM .
ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 2000, 51 :41-63
[8]   Surface plasmon sensor based on the enhanced light transmission through arrays of nanoholes in gold films [J].
Brolo, AG ;
Gordon, R ;
Leathem, B ;
Kavanagh, KL .
LANGMUIR, 2004, 20 (12) :4813-4815
[9]  
Bronstein AM, 2008, MONOGR COMPUT SCI, P1, DOI 10.1007/978-0-387-73301-2_1
[10]   Different approaches for the detection of thrombin by an electrochemical aptamer-based assay coupled to magnetic beads [J].
Centi, S. ;
Messina, G. ;
Tombelli, S. ;
Palchetti, I. ;
Mascini, M. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1602-1609