An improved method for liquid density measurement using NaI(Tl) detector and low-strength source

被引:11
作者
Hoang Duc Tam [1 ]
Nguyen Thi My Le [2 ]
机构
[1] Ho Chi Minh City Univ Educ, Dept Nucl Phys, Fac Phys, 280 Duong Vuong St,Dist 5, Ho Chi Minh City, Vietnam
[2] VNUHCM Univ Sci, Dept Nucl Phys, Fac Phys & Engn Phys, 227 Nguyen Cu St,Dist 5, Ho Chi Minh City, Vietnam
关键词
Liquid density; Gamma scattering; NaI(Tl); Monte Carlo; COMPTON-SCATTERING TECHNIQUE; MONTE-CARLO-SIMULATION; FLUID-FLUID; GAMMA-RAYS; BACKSCATTERING; INSPECTION; THICKNESS; CONCRETE; SAMPLES;
D O I
10.1007/s10967-018-5878-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The current work focuses on using low-strength radiation source and NaI(Tl) detector in liquid density measurement. To do this, the detector collimator is enlarged, which has resulted in the increased multiple scattered events. The scattering spectrum analysis method was applied successfully in removing the multiple scattered component. The obtained single scattering component corresponding to different liquid densities was used to build the linear standard curve which shows the linear dependence between of them with the R (2) values of 0.968 and 0.982 for the collimator diameters of 3.0 and 9.5 cm, respectively. Besides, the Monte Carlo method was used in the current work which the obtained results also support for experimental ones.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 22 条
[1]   Monte Carlo simulation of the NaI(Tl) detector response to measure gold activated foils [J].
Amgarou, K. ;
Domingo, C. ;
Bouassoule, T. ;
Fernandez, F. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (17) :2944-2951
[2]   Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples [J].
Baccouche, S. ;
Al-Azmi, D. ;
Karunakara, N. ;
Trabelsi, A. .
APPLIED RADIATION AND ISOTOPES, 2012, 70 (01) :227-232
[3]   Inspection of reinforced concrete samples by Compton backscattering technique [J].
Boldo, E. M. ;
Appoloni, C. R. .
RADIATION PHYSICS AND CHEMISTRY, 2014, 95 :392-395
[4]   NEW METHOD FOR MEASUREMENT OF BONE MINERAL CONTENT USING BOTH TRANSMITTED AND SCATTERED BEAMS OF GAMMA-RAYS [J].
CLARKE, RL ;
VANDYK, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (04) :532-539
[5]   COMPTON AND RAYLEIGH DOUBLE SCATTERING OF UNPOLARIZED RADIATION [J].
FERNANDEZ, JE .
PHYSICAL REVIEW A, 1991, 44 (07) :4232-4248
[6]   Advanced gamma spectrum processing technique applied to the analysis of scattering spectra for determining material thickness [J].
Hoang Duc Tam ;
Huynh Dinh Chuong ;
Tran Thien Thanh ;
Vo Hoang Nguyen ;
Hoang Thi Kieu Trang ;
Chau Van Tao .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 303 (01) :693-699
[7]   Detection of debonding in composite-aluminum joints using gamma-ray Compton scattering [J].
Jama, HA ;
Hussein, EMA ;
Lee-Sullivan, P .
NDT & E INTERNATIONAL, 1998, 31 (02) :99-103
[8]   Thickness measurement of organic films using Compton scattering of characteristic X-rays [J].
Kim, Jong-Yun ;
Choi, Yong Suk ;
Park, Yong Joon ;
Song, Kyuseok ;
Jung, Sung-Hee ;
Hussein, Esam M. A. .
APPLIED RADIATION AND ISOTOPES, 2011, 69 (09) :1241-1245
[9]  
Knoll G.G., 2010, RAD DETECTION MEASUR, Vfourth
[10]   Monte Carlo simulations of response functions for gas filled and scintillator detectors with MCNPX code [J].
Kovaltchouk, V. ;
Machrafi, R. .