Mesoporous CeO2 nanoparticles modified Glassy carbon electrode for individual and simultaneous determination of Cu(II) and Hg(II): Application to environmental samples

被引:21
|
作者
Adarakatti, Prashanth Shivappa [1 ]
Gangaiah, Vijayakumar [2 ]
Siddaramanna, Ashoka [3 ]
机构
[1] Indian Inst Sci, Solid State & Struct Chem Unit, Bengaluru, India
[2] Bangalore Univ, Cent Coll Campus, Dept Chem, Bengaluru, India
[3] Dayananda Sagar Univ, Sch Engn, Kudlu Gate, Bengaluru, India
关键词
CeO2; nanoparticles; Modified electrode; Anodic stripping voltammetry; Quantification; SIMULTANEOUS ELECTROCHEMICAL DETECTION; PASTE ELECTRODE; SENSITIVE DETERMINATION; COPPER; LEAD; SENSOR; MERCURY; PERFORMANCE; IONS; ZINC;
D O I
10.1016/j.mssp.2018.05.010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An electrochemical sensor based on the use of CeO2 nanoparticles modified glassy carbon electrode (CeO2/GCE) was prepared and applied for determination of Cu(II) and Hg(II) individually and simultaneously. The differential pulse anodic stripping voltammetry (DPASV) results indicates that the CeO2 NPs based sensor exhibits good electroanalytical performance with two well-resolved voltammetric stripping peaks for Cu(II) and Hg(II). The proposed CeO2 NPs based sensor shows a wide linear range from 10 to 350 mu g/L and a lower detection limit (3o) 2.9 for Cu(II) and 3.3 mu g/L for Hg(II) under optimized conditions. The developed sensor was successfully applied for the quantification of Cu(II) and Hg(II) in real sample matrices, and satisfactory results were obtained.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [41] Application of Novel Zn-Ferrite Modified Glassy Carbon Paste Electrode as a Sensor for Determination of Cd(II) in Waste Water
    Stankovic, Dalibor M.
    Skrivanj, Sandra
    Savic, Nenad
    Nikolic, Aleksandar S.
    Vulic, Predrag
    Manojlovic, Dragan D.
    ELECTROANALYSIS, 2014, 26 (07) : 1536 - 1543
  • [43] Electrochemical Determination of Cu(II) Using a Glassy Carbon Electrode Modified with Multiwall Carbon Nanotubes Dispersed in Polyhistidine
    Dalmasso, Pablo R.
    Pedano, Maria L.
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2015, 27 (09) : 2164 - 2170
  • [44] Electrochemical performance of a three-layer electrode based on Bi nanoparticles, multi-walled carbon nanotube composites for simultaneous Hg(II) and Cu(II) detection
    Bao, Qiwen
    Li, Gang
    Yang, Zhengchun
    Pan, Peng
    Liu, Jun
    Chang, Jiayuan
    Wei, Jun
    Lin, Ling
    CHINESE CHEMICAL LETTERS, 2020, 31 (10) : 2752 - 2756
  • [45] Nonenzymatic glucose sensor based on nickel(II)oxide/ordered mesoporous carbon modified glassy carbon electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Ding, Yaping
    Zhang, Zhao
    Deng, Dongmei
    Lu, Bo
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 102 : 307 - 311
  • [46] Calix[4]arene Derivative-Modified Glassy Carbon Electrode: A New Sensing Platform for Rapid, Simultaneous, and Picomolar Detection of Zn(II), Pb(II), As(III), and Hg(II)
    Sultan, Sundus
    Shah, Afzal
    Khan, Burhan
    Nisar, Jan
    Shah, Muhammad Raza
    Ashiq, Muhammad Naeem
    Akhter, Mohammad Salim
    Shah, Aamir Hassan
    ACS OMEGA, 2019, 4 (16): : 16860 - 16866
  • [47] Effect of different copper salts on the electrochemical determination of Cu (II) by the application of the graphene oxide-modified glassy carbon electrode
    Incebay, Hilal
    Yazicigil, Zafer
    SURFACES AND INTERFACES, 2017, 9 : 160 - 166
  • [48] Highly selective simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in water samples using microfluidic paper-based analytical devices
    Kamnoet, Pornphimon
    Aeungmaitrepirom, Wanlapa
    Menger, Ruth F.
    Henry, Charles S.
    ANALYST, 2021, 146 (07) : 2229 - 2239
  • [49] Simultaneous determination of trace Cd(II), Pb(II) and Cu(II) by differential pulse anodic stripping voltammetry using a reduced graphene oxide-chitosan/poly-L-lysine nanocomposite modified glassy carbon electrode
    Guo, Zhuo
    Li, Dong-di
    Luo, Xian-ke
    Li, Ya-hui
    Zhao, Qi-Nai
    Li, Meng-meng
    Zhao, Yang-ting
    Sun, Tian-shuai
    Ma, Chi
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 490 : 11 - 22
  • [50] Simultaneous detection of Cu(II) and Pb(II) in the Danube river using a bismuth film modified glassy carbon rotating disk electrode
    Bounegru, Alexandra Virginia
    Georgescu, Lucian P.
    Iticescu, Catalina
    Apetrei, Constantin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2025, 979