Determination of artesunate using reversed-phase HPLC at increased temperature and ELSD detection

被引:10
作者
Gaudin, Karen [1 ]
Kauss, Tina [1 ]
Lagueny, Anne-Marie [1 ]
Millet, Pascal [1 ]
Fawaz, Fawaz [1 ]
Dubost, Jean-Pierre [1 ]
机构
[1] Univ Bordeaux 2, Fac Pharm, Chim Analyt Lab, PPF Parasitol Pharm, F-33076 Bordeaux, France
关键词
Artesunate; Dihydroartemisinin; FLSD; Increased temperature HPLC; Rectal formulations; PERFORMANCE LIQUID-CHROMATOGRAPHY; LIGHT-SCATTERING DETECTOR; ARTEMISIA-ANNUA L; ANTIMALARIAL-DRUG; PEDIATRIC USE; HUMAN PLASMA; STABILITY; DIHYDROARTEMISININ; OPTIMIZATION; MEFLOQUINE;
D O I
10.1002/jssc.200800437
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Artesunate (ART) determination can be performed by evaporative light scattering detection with mobile phase composed of CH(3)CN/HCOOH 0.01 M (40:60 v/v; pH 2.85). Evaporative light scattering detection instead of ILTV detection allowed to improve the sensitivity and the 1,01). However, the evaporative light scattering detection response of dihydro-artemisinin appears weaker than for ART, whereas with UV detection the response of ART and dihydroartemisinin seemed similar. Constant analysis time was obtained on using the mobile phase with a flow rate of 0.5 mL/min and column temperature at 60 degrees C instead of 0.7 mL/min at room temperature. This led to less solvent consumption. Moreover, decrease in the flow rate and increase in the column temperature were advantageous for higher sensitivity with both evaporative light scattering detection and UV detection. ART determination in rectal gel and suppositories were compared with these different detection modes and similar results were obtained.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 20 条
  • [1] Rapid determination of artemisinin and related analogues using high-performance liquid chromatography and an evaporative light scattering detector
    Avery, BA
    Venkatesh, KK
    Avery, MA
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 730 (01): : 71 - 80
  • [2] Chemical stability of artesunate injection and proposal for its administration by intravenous infusion
    Batty, KT
    Ilett, KF
    Davis, T
    Davis, ME
    [J]. JOURNAL OF PHARMACY AND PHARMACOLOGY, 1996, 48 (01) : 22 - 26
  • [3] Plasmodium falciparum antimalarial drug susceptibility on the north-western border of Thailand during five years of extensive use of artesunate-mefloquine
    Brockman, A
    Price, RN
    van Vugt, M
    Heppner, DG
    Walsh, D
    Sookto, P
    Wimonwattrawatee, T
    Looareesuwan, S
    White, NJ
    Nosten, F
    [J]. TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2000, 94 (05) : 537 - 544
  • [4] New trends in extraction, identification and quantification of artemisinin and its derivatives
    Christen, P
    Veuthey, JL
    [J]. CURRENT MEDICINAL CHEMISTRY, 2001, 8 (15) : 1827 - 1839
  • [5] Response enhancement for the evaporative light scattering detection for the analysis of lipid classes and molecular species
    Deschamps, FS
    Gaudin, K
    Lesellier, E
    Tchapla, A
    Ferrier, D
    Baillet, A
    Chaminade, P
    [J]. CHROMATOGRAPHIA, 2001, 54 (9-10) : 607 - 611
  • [6] Experimental designed optimisation and stability evaluation of dry suspensions with artemisinin derivatives for paediatric use
    Gabriëls, M
    Plaizier-Vercammen, J
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 283 (1-2) : 19 - 34
  • [7] Adaptation of an evaporative light-scattering detector to micro and capillary liquid chromatography and response assessment
    Gaudin, K
    Baillet, A
    Chaminade, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) : 43 - 51
  • [8] In vitro release and stability of an artesunate rectal gel suitable for pediatric use
    Gaudin, Karen
    Barbaud, Anne
    Boyer, Chantal
    Langlois, Marie-Helene
    Lagueny, Anne-Marie
    Dubost, Jean-Pierre
    Millet, Pascal
    Fawaz, Fawaz
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2008, 353 (1-2) : 1 - 7
  • [9] Stability of artesunate in pharmaceutical solvents
    Gaudin, Karen
    Langlois, Marie-Helene
    Barbaud, Anne
    Boyer, Chantal
    Millet, Pascal
    Fawaz, Fawaz
    Dubost, Jean-Pierre
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (03) : 1019 - 1024
  • [10] Micro liquid chromatography coupled with evaporative light scattering detector at ambient and high temperature: Optimization of the nebulization cell geometry
    Guillarme, D.
    Rudaz, S.
    Schelling, C.
    Dreux, M.
    Veuthey, J. -L.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1192 (01) : 103 - 112