Analysis of oxytetracycline residue in salmon muscle using a portable analyzer based on EuIII luminescence

被引:3
作者
Chen, G. [1 ]
Liu, G. [2 ]
机构
[1] ARS, USDA, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
[2] Shanghai Inst Food & Drug Control, Shanghai 201203, Peoples R China
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2009年 / 26卷 / 08期
关键词
extraction; screening assays; veterinary drug residues; tetracycline; fish; PERFORMANCE LIQUID-CHROMATOGRAPHY; EUROPIUM-SENSITIZED LUMINESCENCE; MASS-SPECTROMETRY; FLUORESCENCE DETECTION; TETRACYCLINE; HONEY; ASSAY; FISH; CHLORTETRACYCLINE; CHEMILUMINESCENCE;
D O I
10.1080/02652030903013302
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In the United States, oxytetracycline (OTC) was approved by the Food and Drug Administration (FDA) for use in salmon, catfish and lobster; worldwide, it is the most prominent therapeutant in aquaculture. In this study, OTC and 4-epiOTC residues in salmon muscle were determined using a portable analyzer based on europium-sensitized luminescence (ESL). Extraction was performed first in EDTA/metaphosphoric acid/NaCl/hexane and then in metaphosphoric acid. After centrifugation, cleanup was carried out using hydrophilic-lipophilic balance cartridges. The ESL intensity, integrated over a 25-1000 mu s interval, was linear (r(2) = 0.9999) over three orders of magnitude. In comparison to xenon flashlamp, light-emitting diode (LED) excitation reduced background noise by sixfold to 6.4 ng g(-1). Without prior chromatographic separation, this ESL method/instrument combination achieved 10.9 ng g(-1) limit of detection and <2% average relative standard deviation. Average recovery was 82.0, 83.6 and 86.8% at 50, 100 and 2000 ng g(-1), respectively.
引用
收藏
页码:1172 / 1179
页数:8
相关论文
共 33 条
[1]   ONLINE DIALYSIS, LIQUID-CHROMATOGRAPHY AND POSTCOLUMN REACTION DETECTION OF OXYTETRACYCLINE IN SALMON MUSCLE EXTRACTS [J].
AGASOSTER, T ;
RASMUSSEN, KE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (05) :349-354
[2]   Complexities in tetracycline analysis - chemistry, matrix extraction, cleanup, and liquid chromatography [J].
Anderson, CR ;
Rupp, HS ;
Wu, WH .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :23-32
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF OXYTETRACYCLINE IN CHINOOK SALMON FOLLOWING ADMINISTRATION OF MEDICATED FEED [J].
AOYAMA, RG ;
MCERLANE, KM ;
ERBER, H ;
KITTS, DD ;
BURT, HM .
JOURNAL OF CHROMATOGRAPHY, 1991, 588 (1-2) :181-186
[4]   Sensitive detection of tetracyclines using europium-sensitized fluorescence with EDTA as co-ligand and cetyltrimethylammonium chloride as surfactant [J].
Arnaud, N ;
Georges, J .
ANALYST, 2001, 126 (05) :694-697
[5]   DETERMINATION OF OXYTETRACYCLINE IN FISH BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BJORKLUND, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 432 :381-387
[6]  
Blanchflower WJ, 1997, J CHROMATOGR B, V692, P351
[7]  
CARIGNAN G, 1993, J AOAC INT, V76, P325
[8]   Confirmation of multiple tetracycline residues in milk and oxytetracycline in shrimp by liquid chromatography particle beam mass spectrometry [J].
Carson, MC ;
Ngoh, MA ;
Hadley, SW .
JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2) :113-128
[9]   Portable tetracycline analyzer based on LED-excitation europium-sensitized luminescence [J].
Chen, Guoying .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (02) :750-757
[10]   Europium-sensitized luminescence determination of oxytetracycline in catfish muscle [J].
Chen, GY ;
Schneider, MJ ;
Darwish, AM ;
Lehotay, SJ ;
Freeman, DW .
TALANTA, 2004, 64 (01) :252-257