Immediate post-operative procedure for identification of the rheological parameters of biological soft tissue

被引:4
作者
Durand-Reville, M [1 ]
Tillier, Y [1 ]
Paccini, A [1 ]
Lefloch, A [1 ]
Delotte, J [1 ]
Bongain, A [1 ]
Chenot, JL [1 ]
机构
[1] Univ Hosp, Nice, France
来源
CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS | 2004年 / 1268卷
关键词
indentation test; 3D finite element modelling; soft tissues mechanical behaviour; surgical simulation;
D O I
10.1016/j.ics.2004.03.147
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Computer simulations of minimal invasive procedures have been developed for surgery planning or training or for the evaluation of surgical procedure. In order to perform realistic and precise simulations of surgery on soft tissue, one key step consists in introducing accurate tissue-specific mechanical parameters. The goal of this work was to transfer an indentation procedure from the laboratory to the operating room using a new portable indentation device. The numerical simulations with 3D finite element software of the experiments allowed us to identify the characteristic theological properties which minimize the gap between computed end measured physical quantities. The next step will be to extend this procedure to pathologic uterus and to other solid organs. (C) 2004 CARS and Elsevier B.V. All rights reserved.
引用
收藏
页码:407 / 412
页数:6
相关论文
共 7 条
[1]   Measurements and modelling of the compliance of human and porcine organs [J].
Carter, FJ ;
Frank, TG ;
Davies, PJ ;
McLean, D ;
Cuschieri, A .
MEDICAL IMAGE ANALYSIS, 2001, 5 (04) :231-236
[2]   A novel ultrasound indentation system for measuring biomechanical properties of in vivo soft tissue [J].
Han, LH ;
Noble, JA ;
Burcher, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (06) :813-823
[3]   Inverse finite element characterization of soft tissues [J].
Kauer, M ;
Vuskovic, V ;
Dual, J ;
Szekely, G ;
Bajka, M .
MEDICAL IMAGE ANALYSIS, 2002, 6 (03) :275-287
[4]   How to test very soft biological tissues in extension? [J].
Miller, K .
JOURNAL OF BIOMECHANICS, 2001, 34 (05) :651-657
[5]   Three-dimensional finite element modelling for soft tissues surgery [J].
Tillier, Y ;
Paccini, A ;
Durand-Reville, M ;
Bay, F ;
Chenot, JL .
CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 :349-355
[6]  
TILLIER Y, 2004, IN PRESS P CARS 2004, V1268
[7]   Extraction of quasi-linear viscoelastic parameters for lower limb soft tissues from manual indentation experiment [J].
Zheng, YP ;
Mak, AFT .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (03) :330-339