Development of a new two-enzyme biosensor based on poly(pyrrole-co-3,4-ethylenedioxythiophene) for lactose determination in milk

被引:18
作者
Gursoy, Oguz [1 ]
Sen Gursoy, Songul [2 ]
Cogal, Sadik [3 ]
Cogal, Gamze Celik [4 ]
机构
[1] Mehmet Akif Ersoy Univ, Dept Food Engn, Fac Engn & Architecture, Burdur, Turkey
[2] Mehmet Akif Ersoy Univ, Fac Arts & Sci, Dept Chem, Burdur, Turkey
[3] Mehmet Akif Ersoy Univ, Dept Polymer Engn, Fac Engn & Architecture, Burdur, Turkey
[4] Suleyman Demirel Univ, Inst Nat & Appl Sci, Dept Chem, Isparta, Turkey
关键词
CARBON-PASTE ELECTRODE; GLUCOSE-OXIDASE; BETA-GALACTOSIDASE; HORSERADISH-PEROXIDASE; AMPEROMETRIC BIOSENSOR; HYDROGEN-PEROXIDE; ACID; NANOPARTICLES; SENSOR; FILMS;
D O I
10.1002/pen.24632
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A new lactose biosensor was developed by preparing a suitable copolymer of polypyrrole and poly(3,4-ethylenedioxythiophene) synthesized using the electropolymerization method. Pyrrole and 3,4-ethylenedioxythiophene monomers were deposited in the presence of sodium dodecylbenzene sulphonic acid on a platinum disc electrode, which was used as the working electrode. The sensor is based on the serial reactions of -galactosidase and galactose oxidase immobilized on a copolymer-modified platinum disc electrode. Successful synthesis of the enzyme-immobilized copolymer was confirmed by FT-IR spectrometry, SEM, and electrochemical analysis. The response of the enzyme electrode to lactose was determined by cyclic voltammetry at+0.40 V. The response time of the biosensor was found to be from 8 to 10 s, and the upper limit of the linear working portion was found to be at a lactose concentration of 2.30 mM with a detection limit of 1.4 x 10(-5) M. The apparent Michaelis-Menten constant was found to be 0.65 mM of lactose. The effects of interferents were also investigated. Lactose concentrations determined by the biosensor were in good agreement with those measured by the reference methods. Our results show that the developed biosensor has a significant potential to the determination of lactose concentration in milk. POLYM. ENG. SCI., 58:839-848, 2018. (c) 2017 Society of Plastics Engineers
引用
收藏
页码:839 / 848
页数:10
相关论文
共 74 条
[31]   A novel modified carbon paste electrode based on NiO/CNTs nanocomposite and (9, 10-dihydro-9, 10-ethanoanthracene-11, 12-dicarboximido)-4-ethylbenzene-1, 2-diol as a mediator for simultaneous determination of cysteamine, nicotinamide adenine dinucleotide and folic acid [J].
Karimi-Maleh, Hassan ;
Biparva, Pourya ;
Hatami, Mehdi .
BIOSENSORS & BIOELECTRONICS, 2013, 48 :270-275
[32]  
Kennedy J. F., 1987, BIOTECHNOLOGY A, V7a, P347
[33]   The vitamin C content of cow's milk [J].
Kon, SK ;
Watson, MB .
BIOCHEMICAL JOURNAL, 1937, 31 :223-226
[34]   Poly(pyrrole) versus poly (3,4-ethylenedioxythiophene): implications for biosensor applications [J].
Kros, A ;
Sommerdijk, NAJM ;
Nolte, RJM .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (01) :289-295
[35]   Poly (3,4-ethylenedioxythiophene)-based copolymers for biosensor applications [J].
Kros, A ;
Nolte, RJM ;
Sommerdijk, NAJM .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2002, 40 (06) :738-747
[36]  
Kros A, 2001, ADV MATER, V13, P1555, DOI 10.1002/1521-4095(200110)13:20<1555::AID-ADMA1555>3.0.CO
[37]  
2-7
[38]  
Kros A., 2000, THESIS
[39]   Synthesis, characterization, and morphology of p-toluene sulfonic acid-doped polyaniline:: A material for humidity sensing application [J].
Kulkarni, MV ;
Viswanath, AK ;
Aiyer, RC ;
Khanna, PK .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2005, 43 (16) :2161-2169
[40]   Simultaneous determination of dopamine and serotonin on gold nanocluster/overoxidized-polypyrrole composite modified glassy carbon electrode [J].
Li, Jing ;
Lin, Xiangqin .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (02) :486-493