Clinical indications and radiation doses to the conceptus associated with CT imaging in pregnancy: a retrospective study

被引:24
作者
Woussen, S. [1 ]
Lopez-Rendon, X. [2 ]
Vanbeckevoort, D. [1 ]
Bosmans, H. [1 ]
Oyen, R. [1 ]
Zanca, F. [2 ]
机构
[1] Univ Hosp Leuven, Dept Radiol, Herestr 49, B-3000 Louvain, Belgium
[2] Univ Hosp Leuven, Dept Imaging & Pathol, B-3000 Louvain, Belgium
关键词
Multidetector computed tomography; Pregnancy; Radiation dose; Radiation effects; Conceptus; MONTE-CARLO SIMULATIONS; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; PATIENT; FETUS; GESTATION; MDCT;
D O I
10.1007/s00330-015-3924-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus. Methods A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data. Results The number of CT examinations during pregnancy increased from 3-4 per year in 2008-2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7-60.5 mGy). Conclusions The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy.
引用
收藏
页码:979 / 985
页数:7
相关论文
共 22 条
[1]   Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte Carlo Simulations estimating fetal dose for a range of gestational age and patient size1 [J].
Angel, Erin ;
Wellnitz, Clinton V. ;
Goodsitt, Mitchell M. ;
Yaghmai, Nazanin ;
DeMarco, John J. ;
Cagnon, Christopher H. ;
Sayre, James W. ;
Cody, Dianna D. ;
Stevens, Donna M. ;
Primak, Andrew N. ;
McCollough, Cynthia H. ;
McNitt-Gray, Michael F. .
RADIOLOGY, 2008, 249 (01) :220-227
[2]   Compendium of National Guidelines for Imaging the Pregnant Patient [J].
Austin, Laura M. ;
Frush, Donald P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) :W737-W746
[3]   Contribution of three-dimensional computed tomography in the assessment of fetal skeletal dysplasia [J].
Cassart, M. ;
Massez, A. ;
Cos, T. ;
Tecco, L. ;
Thomas, D. ;
Van Regemorter, N. ;
Avni, F. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (05) :537-543
[4]   Estimation of fetal radiation dose from computed tomography scanning in late pregnancy - Depth-dose data from routine examinations [J].
Damilakis, J ;
Perisinakis, K ;
Voloudaki, A ;
Gourtsoyiannis, N .
INVESTIGATIVE RADIOLOGY, 2000, 35 (09) :527-533
[5]   A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation [J].
Damilakis, John ;
Tzedakis, Antonis ;
Perisinakis, Kostas ;
Papadakis, Antonios E. .
MEDICAL PHYSICS, 2010, 37 (12) :6411-6420
[6]  
Goldberg-Stein S. A., 2012, AM J RADIOL, V198, P352
[7]   The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations [J].
Gu, J. ;
Bednarz, B. ;
Caracappa, P. F. ;
Xu, X. G. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :2699-2717
[8]   Fetal doses to pregnant patients from CT with tube current modulation calculated using Monte Carlo simulations and realistic phantoms [J].
Gu, Jianwei ;
Xu, X. George ;
Caracappa, Peter F. ;
Liu, Bob .
RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) :64-72
[9]   Effectivity of lead aprons to reduce the radiation dose of patient in CT. [J].
Hidajat, N ;
Schroder, RJ ;
Vogl, T ;
Schedel, H ;
Felix, R .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (05) :462-465
[10]   Radiation dose to the fetus from body MDCT during early gestation. [J].
Hurwitz, LM ;
Yoshizumi, T ;
Reiman, RE ;
Goodman, PC ;
Paulson, EK ;
Frush, DP ;
Toncheva, G ;
Nguyen, G ;
Barnes, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) :871-876