Improved 3D Catheter Shape Estimation Using Ultrasound Imaging for Endovascular Navigation: A Further Study

被引:5
|
作者
Chen, Fang [1 ]
Liu, Jia [2 ]
Zhang, Xinran [2 ]
Zhang, Daoqiang [1 ]
Liao, Hongen [2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Comp Sci & Engn, Nanjing 210016, Peoples R China
[2] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 10084, Peoples R China
基金
中国博士后科学基金;
关键词
Endovascular navigation; Ultrasound imaging; Catheter shape estimation; Further study; ABDOMINAL AORTIC-ANEURYSM; GUIDANCE; FLUOROSCOPY; ANGIOGRAPHY; TRACKING; REPAIR;
D O I
10.1109/JBHI.2020.3026105
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: Two-dimensional fluoroscopy is the standard guidance imaging method for closed endovascular intervention. However, two-dimensional fluoroscopy lacks depth perception for the intervention catheter and causes radiation exposure for both surgeons and patients. In this paper, we extend our previous study and develop the improved three-dimensional (3D) catheter shape estimation using ultrasound imaging. In addition, we perform further quantitative evaluations of endovascular navigation. Method: First, the catheter tracking accuracy in ultrasound images is improved by adjusting the state vector and adding direction information. Then, the 3D catheter points from the catheter tracking are further optimized based on the 3D catheter shape optimization with a high-quality sample set. Finally, the estimated 3D catheter shapes from ultrasound images are overlaid with preoperative 3D tissue structures for the intuitive endovascular navigation. Results: the tracking accuracy of the catheter increased by 24.39%, and the accuracy of the catheter shape optimization step also increased by approximately 17.34% compared with our previous study. Furthermore, the overall error of catheter shape estimation was further validated in the catheter intervention experiment of in vitro cardiovascular tissue and in a vivo swine, and the errors were 2.13 mm and 3.37 mm, respectively. Conclusion: Experimental results demonstrate that the improved catheter shape estimation using ultrasound imaging is accurate and appropriate for endovascular navigation. Significance: Improved navigation reduces the radiation risk because it decreases use of X-ray imaging. In addition, this navigation method can also provide accurate 3D catheter shape information for endovascular surgery.
引用
收藏
页码:3616 / 3629
页数:14
相关论文
共 50 条
  • [1] 3D Catheter Shape Determination for Endovascular Navigation Using a Two-Step Particle Filter and Ultrasound Scanning
    Chen, Fang
    Liu, Jia
    Liao, Hongen
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (03) : 685 - 695
  • [2] 3D Catheter Guidance including Shape Sensing for Endovascular Navigation
    Jaeckle, Sonja
    Garcia-Vazquez, Veronica
    von Haxthausen, Felix
    Eixmann, Tim
    Sieren, Malte Maria
    Schulz-Hildebrandt, Hinnerk
    Huttmann, Gereon
    Ernst, Floris
    Kleemann, Markus
    Paetz, Torben
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [3] A Hybrid Approach to 3D Shape Estimation of Catheters Using Ultrasound Images
    Abdulhafiz, Ibrahim
    Janabi-Sharifi, Farrokh
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2023, 8 (04) : 1912 - 1919
  • [4] 3D Visualisation of Navigation Catheters for Endovascular Procedures Using a 3D Hub and Fiber Optic RealShape Technology: Phantom Study Results
    Bydlon, Torre M.
    Torjesen, Alyssa
    Fokkenrood, Steven
    Di Tullio, Alessandra
    Flexman, Molly L.
    EJVES VASCULAR FORUM, 2023, 59 : 24 - 30
  • [5] Improved Catheter Navigation With 3D Electromagnetic Guidance
    Cochennec, Frederic
    Riga, Celia
    Hamady, Mohamad
    Cheshire, Nicholas
    Bicknell, Colin
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (01) : 39 - 47
  • [6] Evaluation of an Electromagnetic 3D Navigation System to Facilitate Endovascular Tasks: A Feasibility Study
    Sidhu, R.
    Weir-McCall, J.
    Cochennec, F.
    Riga, C.
    DiMarco, A.
    Bicknell, C. D.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (01) : 22 - 29
  • [7] Estimation of 2D/3D rigid transformation for Computer-assisted Endovascular Navigation
    Castro, Miguel
    Goeksu, Cemil
    Haigron, Pascal
    Lucas, Antoine
    Urbano, Luis
    2008 3RD INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGIES: FROM THEORY TO APPLICATIONS, VOLS 1-5, 2008, : 1099 - +
  • [8] Using of 3D Virtual Reality Electromagnetic Navigation for Challenging Cannulation in FEVAR Procedure
    Piazza, Roberta
    Condino, Sara
    Alberti, Aldo
    Giannetti, Davide
    Ferrari, Vincenzo
    Gesi, Marco
    Ferrari, Mauro
    AUGMENTED REALITY, VIRTUAL REALITY, AND COMPUTER GRAPHICS, AVR 2017, PT II, 2017, 10325 : 221 - 229
  • [9] A navigation system for flexible endoscopes using abdominal 3D ultrasound
    Hoffmann, R.
    Kaar, M.
    Bathia, Amon
    Bathia, Amar
    Lampret, A.
    Birkfellner, W.
    Hummel, J.
    Figl, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18): : 5545 - 5558
  • [10] Fusion Imaging to Support Endovascular Aneurysm Repair Using 3D-3D Registration
    Schulz, Christof J.
    Schmitt, Matthias
    Boeckler, Dittmar
    Geisbuesch, Philipp
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (05) : 791 - 799