Development of an aptasensor for electrochemical detection of tetracycline

被引:112
作者
Chen, Dan [1 ,2 ]
Yao, Dongsheng [1 ,2 ]
Xie, Chunfang [1 ,3 ,4 ]
Liu, Daling [1 ,3 ,4 ]
机构
[1] Inst Microbial Technol, Guangzhou 510632, Guangdong, Peoples R China
[2] Natl Engn Res Ctr Genet Med, Guangzhou 510632, Guangdong, Peoples R China
[3] Jinan Univ, Guangzhou 510632, Guangdong, Peoples R China
[4] Jinan Univ, Dept Bioengn, Guangzhou 510632, Guangdong, Peoples R China
关键词
Tetracycline; Aptamer; Isothermal Titration Calorimetry; Electrochemical; Detection; LIQUID-CHROMATOGRAPHY; APTAMERS; EVOLUTION; LIGANDS; PROBES; ASSAYS; MILK;
D O I
10.1016/j.foodcont.2014.01.018
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Developing the rapid, simple and sensitive biosensor system for tetracycline detection is very important in food safety. In this paper, we developed a label-free aptasensor for electrochemical detection of tetracycline. The reorganization of tetracycline binding aptamer was confirmed by Isothermal Titration Calorimetry, Kd = 5.18 Chi 10(-5) mol L-1. According to the electrochemical impendence spectroscopy (EIS) analysis, there was a linear relationship between the log concentration of tetracycline and the charge transfer resistance (Delta Ret) from 5.0 to 5.0 Chi 10(3) ng mL(-1) of the tetracycline conc. The detection limit was 1.0 ng mL(-1) within a detection time of 15 min. The average of assemble rate Q was at 82.4% with a differential batches' RSD of 4.6%. The current change of this aptasensor lies within at 8.5% after a storage of 15 days under 4 degrees C. The result aptasensor had shown a good reproducibility with an acceptable stability in tetracycline detection. The recoveries of TET in spiked milk samples were in the range of 90.0 95.7%. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 24 条
[1]  
[Anonymous], 2002, BULLETIN
[2]   High-frequency impedance spectroscopy of platinum ultramicroelectrodes in flowing solutions [J].
Baranski, AS ;
Krogulec, T ;
Nelson, LJ ;
Norouzi, P .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2895-2901
[3]   Quantitative multi-residue method for determination antibiotics in chicken meat using turbulent flow chromatography coupled to liquid chromatography-tandem mass spectrometry [J].
Bousova, Katerina ;
Senyuva, Hamide ;
Mittendorf, Klaus .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1274 :19-27
[4]   Immunochemical determination of oxytetracycline in fish: Comparison between enzymatic and time-resolved fluorometric assays [J].
Chafer-Pericas, Consuelo ;
Maquieira, Angel ;
Puchades, Rosa ;
Miralles, Javier ;
Moreno, Amelia ;
Pastor-Navarro, Nuria ;
Espinos, Francisco .
ANALYTICA CHIMICA ACTA, 2010, 662 (02) :177-185
[5]   Assays for aptamer-based platforms [J].
Citartan, Marimuthu ;
Gopinath, Subash C. B. ;
Tominaga, Junji ;
Tan, Soo-Choon ;
Tang, Thean-Hock .
BIOSENSORS & BIOELECTRONICS, 2012, 34 (01) :1-11
[6]  
Dai M., 2003, STUDY DETECTION TETR
[7]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[8]   Aptasensors for biosecurity applications [J].
Fischer, Nicholas ;
Tarasow, Theodore M. ;
Tok, Jeffrey B-H .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2007, 11 (03) :316-328
[9]   Characterization of DNA probes immobilized on gold surfaces [J].
Herne, TM ;
Tarlov, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (38) :8916-8920
[10]   Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracyclines in milk samples by capillary electrophoresis [J].
Ibarra, Israel S. ;
Rodriguez, Jose A. ;
Miranda, Jose M. ;
Vega, Marisol ;
Barrado, Enrique .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (16) :2196-2202