Use of stopped-flow fluoroimmunoassay in pesticide determination

被引:18
|
作者
Matveeva, EG
AguilarCaballos, MP
Eremin, SA
GomezHens, A
PerezBendito, D
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
[2] MOSCOW MV LOMONOSOV STATE UNIV,DEPT CHEM,DIV CHEM ENZYMOL,MOSCOW 119899,RUSSIA
关键词
immunoassay; fluorimetry; stopped-flow; 2,4-dichlorophenoxyacetic acid; fruit juice samples;
D O I
10.1039/a700439g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stopped-flow fluoroimmunoassay was applied to pesticide detection in foods. For this purpose, a homogeneous immunoassay was developed for the determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in orange and grape juice which is based on the measurement of the initial rate of the reaction between the tracer (fluorescein-labelled 2,4-D) and the antibody. Kinetic methodology avoids the potential interference of the sample matrix, which affects the fluorescence signal obtained at or close to equilibrium. The use of the stopped-flow mixing technique allows analytical data to be obtained automatically and in a few seconds so that the method can be easily applied to routine analysis. The dynamic range of the calibration graph-is 10-400 ng ml(-1) and the relative standard deviation is less than 3%. The analytical recoveries obtained by applying the method to orange and grape juice samples ranged from 91.3 to 102.5%.
引用
收藏
页码:863 / 866
页数:4
相关论文
共 50 条
  • [1] Pesticide determination by stopped-flow fluoroimmunoassay using Cresyl Violet as label
    Aguilar-Caballos, MP
    Gómez-Hens, A
    Pérez-Bendito, D
    ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) : 147 - 154
  • [2] Determination of coproporphyrin in urine by using stopped-flow fluoroimmunoassay
    Matveeva, EG
    Savitsky, AP
    Gómez-Hens, A
    ANALYTICA CHIMICA ACTA, 1998, 361 (1-2) : 27 - 32
  • [3] ESTIMATION OF OPIATES IN URINE BY STOPPED-FLOW FLUOROIMMUNOASSAY
    GAIKWAD, A
    GOMEZHENS, A
    PEREZBENDITO, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11): : 450 - 453
  • [4] Homogeneous stopped-flow fluoroimmunoassay using europium as label
    Aguilar-Caballos, MP
    Härmä, H
    Tuomola, M
    Lövgren, T
    Gómez-Hens, A
    ANALYTICA CHIMICA ACTA, 2002, 460 (02) : 271 - 277
  • [5] FLUORIMETRIC STOPPED-FLOW DETERMINATION OF IODIDE
    TOLEDANO, M
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    ANALUSIS, 1989, 17 (09) : 514 - 518
  • [6] DETERMINATION OF THE DEAD TIME OF A STOPPED-FLOW FLUOROMETER
    BRISSETTE, P
    BALLOU, DP
    MASSEY, V
    ANALYTICAL BIOCHEMISTRY, 1989, 181 (02) : 234 - 238
  • [7] Improved calibration and use of stopped-flow instruments
    Peintler, G
    Nagy, A
    Horváth, AK
    Körtvélyesi, T
    Nagypál, I
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2000, 2 (11) : 2575 - 2586
  • [8] AUTOMATIC STOPPED-FLOW DETERMINATION OF L-CYSTEINE
    CARDOSO, A
    SILVA, M
    PEREZBENDITO, D
    TALANTA, 1989, 36 (09) : 963 - 965
  • [9] STOPPED-FLOW DETERMINATION OF PROCAINE HYDROCHLORIDE IN PHARMACEUTICAL PREPARATIONS
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (04) : 413 - 419
  • [10] STOPPED-FLOW FLUORIMETRIC DETERMINATION OF THEOPHYLLINE IN PHARMACEUTICAL PREPARATIONS
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    ANALYST, 1988, 113 (04) : 559 - 562