Application of graphite-epoxy composite electrodes in differential pulse anodic stripping voltammetry of heavy metals

被引:19
作者
Carrégalo, S [1 ]
Merkoçi, A [1 ]
Alegret, S [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Quim, Grp Sensors & Biosensors, Bellaterra 08193, Catalonia, Spain
关键词
graphite-epoxy composite electrode; anodic stripping voltammetry; lead; copper; cadmium;
D O I
10.1007/s00604-004-0229-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical study on the use of graphite-epoxy composite (GEC) electrodes for differential pulse anodic stripping voltammetry (DPASV) of heavy metals is presented. This study is accompanied by microscopic observations of the electrode surface before and after the stripping step in comparison to glassy carbon electrode. GEC electrodes show much better accumulation properties and consequently acceptable behaviour which makes them suitable as working electrodes in the DPASV of heavy metals. Lead determination in real water samples in a batch system as well as some preliminary results in a flow-through system are presented. The detection limits in batch measurements were 100 ppb for Cd, 10 pb for lead and 50 ppb for copper. The detection limit for lead in the flow-through system was similar to that in the batch. The results obtained show that these low cost and easy to prepare materials can be of interest in future research concerning stripping techniques of heavy metals and other analytes.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 48 条
  • [1] Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters
    Achterberg, EP
    Braungardt, C
    [J]. ANALYTICA CHIMICA ACTA, 1999, 400 : 381 - 397
  • [2] Rigid carbon - Polymer biocomposites for electrochemical sensing - A review
    Alegret, S
    [J]. ANALYST, 1996, 121 (12) : 1751 - 1758
  • [3] Alegret S, 1999, QUIM ANAL, V18, P23
  • [4] GRAPHITE-EPOXY MERCURY THIN-FILM WORKING ELECTRODE FOR ANODIC-STRIPPING VOLTAMMETRY
    ANDERSON, JE
    TALLMAN, DE
    [J]. ANALYTICAL CHEMISTRY, 1976, 48 (01) : 209 - 212
  • [5] Gold electrodes from recordable CDs
    Angnes, L
    Richter, EM
    Augelli, MA
    Kume, GH
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5503 - 5506
  • [6] Rotograved carbon electrodes for amperometric cadmium and lead determination
    Bagel, O
    L'Hostis, E
    Lagger, G
    Osborne, MD
    Seddon, BJ
    Girault, HH
    Brack, D
    Loyall, U
    Schäfer, H
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 469 (02): : 189 - 195
  • [7] Bagel O, 2001, ELECTROANAL, V13, P100, DOI 10.1002/1521-4109(200102)13:2<100::AID-ELAN100>3.0.CO
  • [8] 2-I
  • [9] RAPID ANODIC-STRIPPING ANALYSIS WITH ULTRAMICROELECTRODES
    BARANSKI, AS
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (04) : 662 - 666
  • [10] Simultaneous determination of trace amounts of zinc, lead and copper in rum by anodic stripping voltammetry
    Barbeira, PJS