Boundary-Condition Analysis of an Idealized Left Atrium Model

被引:16
作者
Duenas-Pamplona, Jorge [1 ]
Sierra-Pallares, Jose [2 ]
Garcia, Javier [1 ]
Castro, Francisco [2 ]
Munoz-Paniagua, Jorge [1 ]
机构
[1] Univ Politecn Madrid, Dept Ingn Energet, Escuela Tecn Super Ingn Ind, C Jose Gutierrez Abascal 2, Madrid 28006, Spain
[2] Univ Valladolid, Dept Ingn Energet & Fluidomecan, Escuela Ingn Ind, Paseo Cauce 59, Valladolid 47011, Spain
关键词
Left atrial appendage; Atrial fibrillation; Model validation; Computational fluid dynamics; Particle image velocimetry; Ostium flow; Large eddy simulation; APPENDAGE OCCLUSION; STROKE PREVENTION; FIBRILLATION; RISK; ANTICOAGULATION; WARFARIN; FLOW;
D O I
10.1007/s10439-020-02702-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The most common type of cardiac arrhythmia is atrial fibrillation (AF), which is characterised by irregular and ineffective atrial contraction. This behaviour results into the formation of thrombi, mainly in the left atrial appendage (LAA), responsible for thromboembolic events. Very different approaches are considered as therapy for AF patients. Therefore, it is necessary to yield insight into the flow physics of thrombi formation to determine which is the most appropriate strategy in each case. Computational Fluid Dynamics (CFD) has proven successful in getting a better understanding of the thrombosis phenomenon, but it still requires validation by means of accurate flow field in vivo atrial measurements. As an alternative, in this paper it is proposed an in vitro flow validation, consisting in an idealised model that captures the main flow features observed in the human LA which, once combined with Particle Image Velocimetry (PIV) measurements, provides readily accessible, easy to emulate, detailed velocity fields. These results have been used to validate our laminar and Large Eddy Simulation (LES) simulations. Besides, we have run a parametric study of different boundary conditions sets previously employed in the literature. These data can be used as a benchmark for further development of LA CFD models.
引用
收藏
页码:1507 / 1520
页数:14
相关论文
共 29 条
[1]   In silico Optimization of Left Atrial Appendage Occluder Implantation Using Interactive and Modeling Tools [J].
Aguado, Ainhoa M. ;
Olivares, Andy L. ;
Yague, Carlos ;
Silva, Etelvino ;
Nunez-Garcia, Marta ;
Femandez-Quilez, Alvaro ;
Mill, Jordi ;
Genua, Ibai ;
Arzamendi, Dabit ;
De Potter, Tom ;
Freixa, Xavier ;
Camara, Oscar .
FRONTIERS IN PHYSIOLOGY, 2019, 10
[2]   Left atrial appendage: structure, function, and role in thromboembolism [J].
Al-Saady, NM ;
Obel, OA ;
Camm, AJ .
HEART, 1999, 82 (05) :547-554
[3]   Assessment of the left atrial appendage structure and morphology: comparison of real-time three-dimensional transesophageal echocardiography and computed tomography [J].
Bai, Wenjuan ;
Chen, Zhongxiu ;
Tang, Hong ;
Wang, Hui ;
Cheng, Wei ;
Rao, Li .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (05) :623-633
[4]   The Clinical Assessment of Intraventricular Flows [J].
Bermejo, Javier ;
Martinez-Legazpi, Pablo ;
del Alamo, Juan C. .
ANNUAL REVIEW OF FLUID MECHANICS, VOL 47, 2015, 47 :315-342
[5]   Computational Fluid Dynamic Analysis of the Left Atrial Appendage to Predict Thrombosis Risk [J].
Bosi, Giorgia Maria ;
Cook, Andrew ;
Rai, Rajan ;
Menezes, Leon J. ;
Schievano, Silvia ;
Torii, Ryo ;
Burriesci, Gaetano .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2018, 5
[6]   Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation [J].
Buchmann, N. A. ;
Atkinson, C. ;
Jeremy, M. C. ;
Soria, J. .
EXPERIMENTS IN FLUIDS, 2011, 50 (04) :1131-1151
[7]   Atrial fibrillation and ventricular dysfunction - A vicious electromechanical cycle [J].
Cha, YM ;
Redfield, MM ;
Shen, WK ;
Gersh, BJ .
CIRCULATION, 2004, 109 (23) :2839-2843
[8]   Left Atrial Appendage Occlusion for Stroke Prevention [J].
Chanda, Arijit ;
Reilly, John P. .
PROGRESS IN CARDIOVASCULAR DISEASES, 2017, 59 (06) :626-635
[9]   Estimation of uncertainty bounds for individual particle image velocimetry measurements from cross-correlation peak ratio [J].
Charonko, John J. ;
Vlachos, Pavlos P. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (06)
[10]   Image-based large-eddy simulation in a realistic left heart [J].
Chnafa, C. ;
Mendez, S. ;
Nicoud, F. .
COMPUTERS & FLUIDS, 2014, 94 :173-187