Clinical validation of dual-source dual-energy computed tomography (DECT) for coronary and valve imaging in patients undergoing transcatheter aortic valve implantation (TAVI)

被引:12
作者
Mahoney, R. [1 ]
Pavitt, C. W. [2 ,3 ]
Gordon, D. [4 ]
Park, B. [4 ]
Rubens, M. B. [2 ,5 ]
Nicol, E. D. [2 ,3 ,5 ]
Padley, S. P. [2 ,5 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, London SW7 2AZ, England
[2] Royal Brompton Hosp, Dept Radiol, London SW3 6NP, England
[3] Royal Brompton Hosp, Dept Cardiol, London SW3 6NP, England
[4] Royal Marsden Hosp, Dept Phys, London SW3 6JJ, England
[5] Univ London Imperial Coll Sci Technol & Med, Fac Med, London SW7 2AZ, England
关键词
ARTERY CALCIUM; TUBE VOLTAGE; CT; QUANTIFICATION; ANGIOGRAPHY; ACQUISITION; DISEASE;
D O I
10.1016/j.crad.2014.03.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess the validity of virtual non-contrast (VNC) reconstructions for coronary artery calcium (CACS) and aortic valve calcium scoring (AVCS) in patients undergoing trans-catheter aortic valve implantation (TAVI). MATERIALS AND METHODS: Twenty-three consecutive TAVI patients underwent a three-step computed tomography (CCT) acquisition: (1) traditional CACS; (2) dual-energy (DE) CT coronary angiogram (CTCA); and (3) DE whole-body angiogram. Linear regression was used to model calcium scores generated from VNC images with traditional scores to derive a conversion factor [2.2 (95% CI: 1.97-2.58)]. The effective radiation dose for the TAVI protocol was compared to a standard control group. Bland-Altman analysis and weighted k-statistic were used to assess inter-method agreement for absolute score and risk centiles. RESULTS: CACS and AVCS from VNC reconstructions correlated well with traditional scores (r = 0.94 and r = 0.86; both p < 0.0001). There was excellent agreement between VNC and non-contrast coronary calcium scores [mean difference -71.8 (95% limits of agreement -588.7 to 445.1)], with excellent risk stratification into risk centiles (k = 0.99). However, the agreement was weaker for the aortic valve [mean difference -210.6 (95% limits of agreement -1233.2 to 812)]. Interobserver variability was excellent for VNC CACS [mean difference of 6 (95% limits of agreement 134.1-122.1)], and AVCS [mean difference of -16.4(95% limits of agreement 576 to -608.7)]. The effective doses for the DE TAVI protocol was 16.4% higher than standard TAVI protocol (22.7 versus 19.5 mSv, respectively) accounted for by the DE CTCA dose being 47.8% higher than that for a standard CTCA [9.9(5.6-14.35) versus 6.7 (1.17-13.72) mSv; p < 0.01). CONCLUSIONS: CACS and AVCS can be accurately quantified, and patients can be risk stratified using DECT VNC reconstructions. However, the dose from DE CTCA is significantly greater than the standard single-energy CTCA precluding the use of this technology in routine clinical practice. (C) 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:786 / 794
页数:9
相关论文
共 25 条
[1]   SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) [J].
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Schoenhagen, Paul ;
Min, James K. ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :366-380
[2]   Cardiovascular risk assessment based on the quantification of coronary calcium in contrast-enhanced coronary computed tomography angiography [J].
Bischoff, Bernhard ;
Kantert, Claudia ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Martinoff, Stefan ;
Schoemig, Albert ;
Hausleiter, Joerg .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (06) :468-475
[3]   Impact of a Reduced Tube Voltage on CT Angiography and Radiation Dose Results of the PROTECTION I Study [J].
Bischoff, Bernhard ;
Hein, Franziska ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Martinoff, Stefan ;
Schoemig, Albert ;
Hausleiter, Joerg .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (08) :940-946
[4]   Repeatability limits for measurement of coronary artery calcified plaque with cardiac CT in the multi-ethnic study of atherosclerosis [J].
Chung, Hyoju ;
McClelland, Robyn L. ;
Katz, Ronit ;
Carr, J. Jeffrey ;
Budoff, Matthew J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) :W87-W92
[5]   Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function [J].
Delgado, Victoria ;
Ng, Arnold C. T. ;
van de Veire, Nico R. ;
van der Kley, Frank ;
Schuijf, Joanne D. ;
Tops, Laurens F. ;
de Weger, Arend ;
Tavilla, Giuseppe ;
de Roos, Albert ;
Kroft, Lucia J. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (09) :1114-1123
[6]   Controversies about effects of low-kilovoltage MDCT acquisition on Agatston calcium scoring [J].
Deprez, Fabrice C. ;
Vlassenbroek, Alain ;
Ghaye, Benoit ;
Raaijmakers, Rolf ;
Coche, Emmanuel .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (01) :58-61
[7]   Effect of Concomitant Coronary Artery Disease on Procedural and Late Outcomes of Transcatheter Aortic Valve Implantation [J].
Dewey, Todd M. ;
Brown, David L. ;
Herbert, Morley A. ;
Culica, Dan ;
Smith, Craig R. ;
Leon, Martin B. ;
Svensson, Lars G. ;
Tuzcu, Murat ;
Webb, John G. ;
Cribier, Alain ;
Mack, Michael J. .
ANNALS OF THORACIC SURGERY, 2010, 89 (03) :758-767
[8]   2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement [J].
Holmes, David R., Jr. ;
Mack, Michael J. ;
Kaul, Sanjay ;
Agnihotri, Arvind ;
Alexander, Karen P. ;
Bailey, Steven R. ;
Calhoon, John H. ;
Carabello, Blase A. ;
Desai, Milind Y. ;
Edwards, Fred H. ;
Francis, Gary S. ;
Gardner, Timothy J. ;
Kappetein, A. Pieter ;
Linderbaum, Jane A. ;
Mukherjee, Chirojit ;
Mukherjee, Debabrata ;
Otto, Catherine M. ;
Ruiz, Carlos E. ;
Sacco, Ralph L. ;
Smith, Donnette ;
Thomas, James D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) :1200-1254
[9]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[10]   Dose levels at coronary CT angiography-a comparison of Dual Energy-, Dual Source- and 16-slice CT [J].
Kerl, J. Matthias ;
Bauer, Ralf W. ;
Maurer, Tobias B. ;
Aschenbach, Rene ;
Korkusuz, Huedayi ;
Lehnert, Thomas ;
Deseive, Simon ;
Ackermann, Hanns ;
Vogl, Thomas J. .
EUROPEAN RADIOLOGY, 2011, 21 (03) :530-537